35.18 - 707.4 Location.
Section 707.4 Location is modified as follows (keeping the four exceptions as written): Location. Each horizontal drainage pipe shall be provided with a clean-out at its upper terminal and each run of piping, that is more than fifty (50) feet in total developed length, shall be provided with a clean-out for each fifty (50) feet, or fraction thereof, in length of such piping unless an alternate is approved by the Authority Having Jurisdiction. All slab constructed buildings and multiple building units shall be provided with an approved two-way clean-out fitting (Siamese) outside of a building at the lower end of the building drain extended to grade. Building sewers shall be provided with a full size clean out within two feet (2') of any building or structure. (Exterior or interior installation.) Clean-outs will not be required to be larger than 4" in diameter. (041-25)