§ 5-121.336 — Decks and patios in coastal high hazard areas (Zone V) and Coastal A Zones
Code of Ordinances, City of Tampa (Supp. No. 148: codified through Ordinance No. 2025-152, enacted December 18, 2025) · Tampa City Code § 5-121.336
Corpus is an independent public-information project, not the official City of Tampa website. Stable reference: corpuslaw.us/code/b743a451-67d8-400d-8940-aa83e9fa8a76
Sec. 5-121.336. - Decks and patios in coastal high hazard areas (Zone V) and Coastal A Zones.
In addition to the requirements of the Florida Building Code, in coastal high hazard areas and Coastal A Zones decks and patios shall be located, designed, and constructed in compliance with the following: 1. A deck that is structurally attached to a building or structure shall have the bottom of the lowest horizontal structural member at or above the design flood elevation and any supporting members that extend below the design flood elevation shall comply with the foundation requirements that apply to the building or structure, which shall be designed to accommodate any increased loads resulting from the attached deck. 2. A deck or patio that is located below the design flood elevation shall be structurally independent from buildings or structures and their foundation systems, and shall be designed and constructed either to remain intact and in place during design flood conditions or to break apart into small pieces to minimize debris during flooding that is capable of causing structural damage to the building or structure or to adjacent buildings and structures. 3. A deck or patio that has a vertical thickness of more than six (6) inches or that is constructed with more than the minimum amount of fill necessary for site drainage shall not be approved unless an analysis prepared by a qualified registered design professional demonstrates no harmful diversion of floodwaters or wave runup and wave reflection that would increase damage to the building or structure or to adjacent buildings and structures. 4. A deck or patio that has a vertical thickness of six (6) inches or less and that is at natural grade or on nonstructural fill material that is similar to and compatible with local soils and is the minimum amount necessary for site drainage may be approved without requiring analysis of the impact on diversion of floodwaters or wave runup and wave reflection.
(Ord. No. 2024-15, § 2(Exh. A), 2-1-2024)
Ask a question about Tampa law
Corpus searches the Tampa sections it holds and shows the ones that match, with their citations. Free, no sign-in.
