Sec. 26-26. - Adoption; amendments.
(1) The 2018 International Fire Code, and all associated codes, standards, all appendices with the exception of appendices A and J, all of which are included herein by reference are hereby approved and adopted with the following revisions and additions: (a) Revisions: 2016 edition of NFPA 72 903.2.1.1 Group A-1 (1) The fire area exceeds 10,000 square feet. 903.2.1.3 Group A-3 (1) The fire area exceeds 10,000 square feet. 903.2.1.4 Group A-4 (1) The fire area exceeds 10,000 square feet. 903.2.3 Group E (1) All buildings. 903.2.4 Group F-1 (1) The fire area exceeds 10,000 square feet. (3) The combined area of all Group F-1 fire areas on all floors, including any mezzanines, exceeds 20,000 square feet. 903.2.7 Group M (1) The fire area exceeds 10,000 square feet. (3) The combined area of all Group M-1 fire areas on all floors, including any mezzanines, exceeds 20,000 square feet. 903.2.9 Group S-1 (1) The fire area exceeds 10,000 square feet. (3) The combined area of all Group S-1 fire areas on all floors, including any mezzanines, exceeds 20,000 square feet. 903.2.10 Group S-2 (1) The fire area exceeds 10,000 square feet. Section 1017.2.2 to include Table 1017.2 The maximum exit access travel distance shall be 400 feet (122m) in Group F-1 or S-1 occupancies where all of the following conditions are met: 1. The portion of the building classified as Group F-1 or S-1 is limited to one story in height. 2. The minimum height from the finished floor to the bottom of the ceiling or roof slab or deck is 24 feet (7315m). 3. The building is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1. The provisions set forth above for conditional approval of maximum exit access travel distance for Group F-1 or S-1 occupancies shall not apply to buildings used for the bulk storage/distribution of tires or mattresses, as the required exit travel distance for those uses are governed by a separate section of the Code. (b) Additions: 501.5 Nuisance alarms from fire and or burglar alarms systems.False alarms are wasteful of limited city resources, pose a threat to public safety, and should be limited when and where possible. The Mayor and Board find as fact that certain false alarms may constitute a nuisance which should be abated. The responsibility for any fire and or burglar alarm activation shall be placed on the premises owner or occupant of the premises where the fire and or burglar alarm system is installed. 501.5.1 Definitions. The following words, terms and phrases, when used, shall have the meanings ascribed to them in this section, except where the context clearly indicates a different meaning: A "Response" to an alarm activation shall be considered any situation where a member of the Olive Branch Fire or Police Department is dispatched to the premises where the fire or burglar alarm activation occurred; or where a member of the Olive Branch Fire or Police Department learns of an alarm activation by any means whatsoever and responds to that premises for investigation of an alarm transmission. Emergency, Fire, or Burglar Alarm systems means an assembly of equipment or devices which is designed, arranged, or used for the detection of a hazardous and or threatening condition in a building, structure or facility, and which emits a sound, or transmits a signal or message when activated, to which annunciation the Fire Department agency or other emergency service may be summoned to respond. False alarm means the activation of an alarm system through mechanical failure, malfunction, improper installation or maintenance, or through the negligence, whether intentional or unintentional, of the owner, user or alarm systems contractor of the alarm system, which activation results in a response by the Fire and or Police Department. Malicious false alarm means false reporting to the Fire or Police Department of an emergency or threatening condition, or the intentional setting off of an alarm system which will cause another to report the signal. An alarm is not considered a false alarm if the alarm is activated due to malicious causes beyond control of the owner, if reasonable proof is shown. Notice means written notice, given by the issuance of a citation left at the scene of a false alarm by officers of the Fire Department, Police Department, or given by U.S. mail addressed to the owner or lessee to be notified at his last known address. Service of such notice shall be effective upon the completion of personal service or upon the placing of the same in the custody of the U.S. Postal Service. 501.5.2 Corrective action. After responding to a false fire or burglar alarm activation, the officer or member of the Fire or Police Department shall issue a "False Alarm Activation Report" indicating whether the alarm was a result of a malfunction of the respective alarm system. Any report indicating that the activation was due to a malfunction shall require the owner/operator to return a completed affidavit of service/repair to the respective responding agency (Fire/Police) within 15 days indicating that a bona fide fire/burglar alarm technician of record has inspected/repaired the system to identify and correct any defect of design, installation or operation of the system, which was the cause of the false alarm activation, to the satisfaction of the Fire or Police Department official. Failure to return the required affidavit of service/repair or failure to make any necessary repairs shall be considered a violation of this Section. 501.5.3 Penalties. In the event of a false alarm or malicious false alarm, the responsible party shall be summonsed to Municipal Court and shall upon conviction pay a penalty of one hundred dollars ($100.00) for any false alarm received by the Fire and or Police Services division after a maximum of three (3) false alarms have previously been received from the same fire or burglar alarm system within any twelve-month period. The twelve month period shall be calculated on a calendar year basis. 501.5.4 Fire Alarm System Components. All Fire Alarm Control Panels (FACP) and the components of which they consist, including any ancillary components that provide support to the system such as any type of initiating device, heat sensor, smoke detector, horn strobe etc., shall be listed by Underwriters Laboratories (UL), and/or Factory Mutual (FM), or other certifying laboratory accepted by the Fire Marshal. This subsection is intended to reduce instances of nuisance or false alarms and is applicable to all Fire Alarm System Components, regardless of whether the system has produced a nuisance or false alarm. 903.4 Sprinkler system supervision and alarms. (a) Multi-Tenant Occupancy. Every potential occupancy space shall have a sprinkler cutoff valve and water flow switch installed for accurate response from Fire Department personnel and to eliminate potential hazard from the entire building being disconnected from water system during construction of future tenant spaces. 903.5 Water supplies. (a) Commercial/Industrial Sprinkler Service. All fire service mains or hydrants that are part of a Commercial/Industrial Fire Suppression System/Fire Loop shall be installed by a licensed sprinkler contractor who shall install the underground portion of the fire suppression system beginning at the City connection with approved materials. Fire Loop Hydrants shall be located not less than 40 ft. (12.2 m) from the buildings to be protected. Hydrants shall be installed so that the steamer cap opening is facing the street and clears the finished grade by 18 inches or more in height. 903.3.7 Fire department connections. (a) Any building larger than one story, requiring a sprinkler system, shall have the Fire Department Connection placed away from the building, no closer than one and one-half times the height of the building. 903.6 Where required in existing buildings and structures. (a) For any buildings constructed after December 1997, if an addition or additions are made to such building, and if the addition or additions cause the total building to exceed 10,000 square feet of gross floor area, the entire building (including the existing and newly added areas) shall be subject to this sprinkler requirement.
(Ord. of 5-20-14(2), §§ 1—3; Ord. of 11-15-16(1), § 1; Ord. of 12-6-17(1), § 1; Ord. of 5-7-2019(1), § 1)
Ask a question about Olive Branch law
Corpus searches the Olive Branch sections it holds and shows the ones that match, with their citations. Free, no sign-in.