For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 18.10.240 — Section P2603.5.3 Plumbing within exterior walls, added

El Paso City Code (Supp. No. 95, Update 4: codified through Ordinance No. 019889, enacted June 23, 2026) · El Paso City Code § 18.10.240

Corpus is an independent public-information project, not the official City of El Paso website. Stable reference: corpuslaw.us/code/b9a62934-497f-4b7d-9c98-09523baee880

18.10.240 - Section P2603.5.3 Plumbing within exterior walls, added.

International Residential Code, 2021 Edition, Section 2903.1.2 Plumbing within exterior walls, is hereby added to read as follows: P2603.5.3 Plumbing within exterior walls. Placement of plumbing within exterior walls is prohibited unless the walls are at minimum, 2 by 6 walls and adequate provision is made to protect such pipes from freezing in accordance with Section 305.6 of the International Plumbing Code. Placement of water lines in ceiling areas is prohibited unless the water lines are placed on the warm side with a minimum of 10 inch insulation on the exterior/roof side of the structure. Exceptions: a. A service entrance may enter a non-conditioned space provided that the riser/service entrance is within an approved, heated valve protective enclosure also known as a "hot box", or b. Cross linked polyethylene, also known as PEX, or approved equal, is used as the service entrance material, and c. Any hose bibs installed shall be freeze proof.

(Ord. No. 019528, § 1, 8-1-2023)

Ask a question about El Paso law

Corpus searches the El Paso sections it holds and shows the ones that match, with their citations. Free, no sign-in.