§ 12-153. - Building requirements for a minimum noise level reduction of 25 decibels (dB).
The following are building requirements for a minimum noise level reduction of 25 decibels (dB): (1) the following shall apply to exterior walls: a. masonry walls shall be equivalent in weight to six-inch minimum lightweight concrete block. At least one surface shall be painted or plastered. A furred interior wall is not required on the inside of masonry walls. b. siding-on-sheathing, stucco or brick veneer shall be installed on the outside of minimum four-inch nominal deep studs. c. interior wall surface of exterior wall shall be minimum one-half-inch gypsum board or plaster installed on the inside of the wall studs. d. continuous sheathing shall cover the exterior side of the wall studs behind wood, asphalt or aluminum siding. The sheathing shall be minimum one-half-inch thick. e. sheathing boards or panels shall be butted tightly and covered on the exterior with overlapping and airtight building paper when wood sheathing is used. f. a minimum thermal resistance (R) factor of 13 shall be provided in the cavity space behind the exterior sheathing and between wall studs with glass fiber or mineral wool. g. brick veneer, masonry blocks, or stucco walls shall be constructed airtight except as otherwise required by the Code. All surface joints shall be grouted or caulked airtight. h. penetration of wall by pipes or ducts shall be caulked or filled with mortar. (2) the following shall apply to windows: a. glass of single-glazed windows shall be minimum 3/16 -inch thick. b. glass of double-glazed windows shall be of standard manufacturers' width and separation. c. all operable windows in these dwellings shall contain hinged-type sash or double-hung sash. The sash shall be rigid and weather stripped with an efficiently airtight, flexible nonmetallic material that is compressed airtight when the window is closed. d. horizontally sliding sash windows may be used only if the sash is weather stripped with an efficiently airtight gasket and if the window has a laboratory sound transmission rating of STC-28 or greater. e. glass for fixed-sash windows shall be set and sealed in an airtight nonhardening glazing compound or in an elastomer gasket. f. the perimeter of window frames shall be sealed airtight to the exterior wall construction. (3) the following shall apply to doors: a. all exterior doors shall be 1¾-inch solid core wood or metal-clad doors and shall be fully weather stripped in an airtight manner. b. sliding doors may be used if the operable sash is weather stripped with an efficient airtight gasket and if the door has a laboratory sound transmission rating of STC-28 or greater. Glass of sliding doors shall be minimum 3/16 -inch thick. c. the perimeter of door frames shall be sealed airtight to the exterior wall construction. (4) the following shall apply to ceilings: a. minimum one-half-inch thick gypsum board or plaster ceilings shall be provided below attic space or roof rafters or roof construction less than eight psf. b. a minimum thermal resistance (R) factor of 30 shall be provided above the ceiling between the joists. Insulation in attic space shall have no paper or foil covering on the face exposed to the attic. (5) the following provisions shall apply to ventilation: a. mechanical ventilation shall be provided of a type and design to provide adequate environmental comfort with all doors and windows closed during all seasons. b. window and through-the-wall ventilation units shall not be used. c. vent openings in attic or crawl spaces shall be minimum in number and size to provide proper ventilation. A "vent" shall mean a conduit or passageway, vertical or nearly so, for conveying products of combustion to the outside atmosphere. d. return air duct lining shall be one-inch minimum coated glass fiber duct liner. e. fireplaces shall be provided with well-fitted dampers.
(Ord. No. 24439, § II, 4-3-12; Ord. No. 26248, § 6, 9-24-19)
Ask a question about Oklahoma City law
Corpus searches the Oklahoma City sections it holds and shows the ones that match, with their citations. Free, no sign-in.