STANDARDS FOR DESIGN REVIEW
Salt Lake City Code § 21A.59.050
in effect21A.59.050: STANDARDS FOR DESIGN REVIEW:
A. Any new development shall comply with the intent of the purpose statement of the zoning district and specific design regulations found within the zoning district in which the project is located as well as the city's adopted "urban design element" and adopted general plan policies and design guidelines governing the specific area of the proposed development.
B. Development shall be primarily oriented to the sidewalk, not an interior courtyard or parking lot by including:
1. Primary entrances that face the public sidewalk (secondary entrances can face a parking lot);
2. Building(s) located close to the public sidewalk, following the desired development patterns of the immediate vicinity; and
3. Parking located within, behind, or to the side of buildings.
C. Building facades shall facilitate pedestrian interest and interaction by including:
1. Active ground floor uses at or close to the public sidewalk;
2. Maximum transparency of street facing facades. Ground floor glass shall not have reflective treatments, be covered by interior walls or opaque signage, or use other similar features that prevent passers-by from seeing inside of the building for non-residential uses;
3. Traditional storefront elements such as sign bands, clerestory glazing, articulation, and architectural detail at window transitions on the ground floor. If the ground floor contains residential uses, each primary building entrance and individual unit entrance shall include a defined entry feature;
4. Buildings located on corner lots shall incorporate architectural features that emphasize the building's corner, including a prominent building entrance that is publicly accessible, transparent, and unobstructed; and
5. Outdoor dining patios, courtyards, plazas, habitable landscaped yards, and open spaces, if provided, should be situated so that they have a direct visual connection to the street or midblock walkway.
D. Building masses shall be divided into heights and proportions that minimize the perceived mass of the structure and relate to human scale by demonstrating compliance with the following standards:
1. Relate building scale and massing to the size and scale of the surrounding buildings, and context of the site, such as alignments with existing foundation lines, established cornice heights, building massing, stepbacks and vertical emphasis;
2. For buildings with more than three stories, compose the design of a building with a distinct base to create a sense of human scale orientation. For buildings taller than fifty feet (50'), the height of the base shall be at least twenty feet (20'). For buildings taller than one hundred feet (100'), the minimum base height should be three stories or be consistent with the existing street wall;
3. Include secondary architectural elements such as balconies, porches, vertical bays, belt courses, fenestration or window reveals; and
4. Reflect the scale and solid (wall) to void (window/door openings) ratio of the established character of the neighborhood or that which is desired in the general plan. Windows shall have a consistent spacing pattern and alignment.
E. This subsection is only applicable to buildings requesting additional street facing building façade length. Street facing building facades shall contribute to the character of the neighborhood, reinforce the established street wall, promote ground-level activation, create a sense of enclosure, and be designed to minimize negative impacts on the streetscape. The street facing building façade may only be increased up to twenty five percent (25%) of the allowed maximum in Section 21A.37.060, subject to the following standards:
1. Reductions to the ground floor use requirement of the underlying zoning district, as specified in Section 21A.37.060, are not permitted. For zoning districts without a designated ground floor use requirement, a minimum of seventy five percent (75%) of the ground floor shall contain qualifying active uses as defined in Section 21A.37.050.A.
2. Building facades that exceed the maximum street facing façade length shall be designed to reduce the perceived length of the façade and provide visual interest, by including elements such as:
a. Significant changes in wall plane measuring at least two feet (2');
b. Massing changes; or
c. Distinguished roof lines.
3. Exemptions:
a. The following land use are exempt from the maximum increase of twenty five percent (25%) of building façade and the reduction in ground floor use provision above: utility buildings and structures (other than the offices for utility providers), stadiums/arenas, libraries, convention centers, places of worship, government offices, public and private schools, universities, movie theaters, live performance theaters, and other similar general assembly land uses as determined by the zoning administrator.
b. Developments that comply with the affordability level in Table 21A.52.050.G Affordable Housing Incentives may exceed the building length by up to seventy five percent (75%) of the allowed maximum in Section 21A.37.060. Such developments shall be subject to Subsections 21A.52.050.E and F.
F. If provided, publicly accessible outdoor spaces shall include at least three (3) of the seven (7) following elements:
1. At least one sitting space for each two hundred fifty (250) square feet shall be included in the plaza. Seating shall be a minimum of sixteen inches (16") in height and thirty inches (30") in width. Ledge benches shall have a minimum depth of thirty inches (30");
2. Seasonal shade in the form of permanent shade structures, pergolas, or overhanging building elements such as canopies that enhance comfort and usability of the space;
3. Trees in proportion to the space at a minimum of one tree per eight hundred (800) square feet. At the time of planting, deciduous trees shall have a minimum trunk size of one and a half inches (1.5") in caliper, while evergreen trees shall have a minimum size of five feet (5') in height;
4. Water features or public art;
5. Outdoor dining areas;
6. Children's amenity space in the form of playgrounds, splash pads, or other similar features; or
7. Other amenities not listed above that provide a public benefit.
G. This subsection is only applicable to buildings requesting additional building height, as authorized in the underlying zoning district. Building height shall be modified to relate to human scale and minimize negative impacts by demonstrating compliance with the following standards:
1. Design tall buildings to minimize wind impacts on primary building entrances, parks and open space, and public and private outdoor amenity areas. Design elements may include a wind break above the first level of the building, recessed entryways or vestibules, or canopies;
2. Design and orient buildings to prevent snow, ice, or water from falling directly onto a public sidewalk, public space, neighboring property, or directly onto the walkway leading to the building entrance;
3. Roof-top mechanical equipment shall be screened from public view; and
4. Buildings abutting a landmark site shall feature at least one horizontal element on the street facing façade (base, belt course, frieze, cornice) that aligns with a corresponding element of the historic building. The alignment shall foster visual continuity and respect the historic context.
H. Parking and on site circulation shall be provided with an emphasis on making safe pedestrian connections to the sidewalk, transit facilities, or midblock walkway. Parking lots and structures shall be setback a minimum of twenty five feet (25') from required midblock pedestrian access locations or as required in the underlying zoning district if the underlying zoning requires a larger setback.
I. Screening of Service Areas: Service areas, loading facilities, refuse containers, utility meters, and similar areas shall be fully screened from public view or located along a side yard. All screening enclosures viewable from the street shall be either incorporated into the building architecture or shall incorporate building materials and detailing compatible with the building being served.
J. Site and building lighting shall support pedestrian comfort and safety, neighborhood image, and dark sky goals.
1. Outdoor lighting should be designed for low-level illumination and to minimize glare and light trespass onto abutting properties and uplighting directly to the sky.
2. Coordinate lighting with architecture, signage, and pedestrian circulation to accentuate significant building features, improve sign legibility, and support pedestrian comfort and safety.
K. Streetscape improvements shall be provided as follows:
1. Impervious surfaces shall be utilized to differentiate privately-owned public spaces from public spaces. All paving for public sidewalks shall follow applicable design standards. Permitted materials for privately-owned public spaces shall meet the following standards:
a. Use materials that are durable (withstand wear, pressure, damage), require a minimum of maintenance, and are easily repairable or replaceable.
b. Where practical, as in lower-traffic areas, use materials that allow rainwater to infiltrate into the ground and recharge the water table.
c. Limit contribution to urban heat island effect by limiting use of dark materials and incorporating materials with a high Solar-Reflective Index (SRI).
d. Utilize materials and designs that have an identifiable relationship to the character of the site, the neighborhood, or Salt Lake City.
e. Use materials (like textured ground surfaces) and features (like ramps and seating at key resting points) to support access and comfort for people of all abilities.
f. Asphalt shall be limited to vehicle drive aisles. (Ord. 51- 25, 2025: Ord. 70-24, 2024: Ord. 24B-23, 2023: Ord. 24-23, 2023: Ord. 14-19, 2019)
Source: Salt Lake City, Utah, City Code (American Legal Publishing, codelibrary.amlegal.com)URL: https://codelibrary.amlegal.com/codes/saltlakecityut/latest/saltlakecity_ut/0-0-0-71197Fetched: 11/1/2026