§ 6-11 — Site Plan requirements
Code of Ordinances of the City of Tyler, Texas (September 2026: including amendments through September 9, 2026) · Tyler City Code § 6-11
Corpus is an independent public-information project, not the official City of Tyler website. Stable reference: corpuslaw.us/code/bb38425e-dd81-4e61-a47d-e2df9a5beb2f
Sec. 6-11. Site Plan requirements.
a. In this section, a residential lot is a lot developed or to be developed with either a single-family housing unit or a duplex. Site Plans submitted to the Building Official for a residential lot shall include: 1. Lot and block number; 2. Platted boundaries of the lot; 3. Exterior dimensions of lot drawn to scale; 4. Street address; 5. Zoning classification; 6. All setbacks; 7. All easements on the lot; 8. Location of curbs, storm sewers, adjacent street and public right-of-way lines, dimensions and locations of driveways, and edge of roadway; 9. Finished floor elevations and location of any designated floodplains or floodways within the boundaries of the lots; 10. Location of all drainage swales and berms on the lot and arrows showing the direction of the drainage flow on the lot; 11. Name, address, and phone number of the individuals responsible for the project; 12. The Plan shall be digital and shall be drawn to scale in the scale shown; 13. Door and window schedule; 14. Floor plans drawn to scale with all required doors and windows properly sized; 15. The following retaining walls shall be designed and sealed by a Professional Engineer licensed to practice in the State of Texas: a. Any retaining wall(s) that supports a building, driveway or other permanent construction or imposed load that is located closer to the wall than one and one-half (1 ½) times the exposed height of the wall. b. Any retaining wall equal to or greater than four (4) feet high when measured from final grade to the top of the wall. c. A series of two or more walls built in tiers shall be considered a single wall in height when the base of the upper tier is set back from the base of the lower tier less than one and one-half (1 ½ ) times the height of the exposed wall height below. 16. Digital drawings shall be submitted to the Building Services Department. b. In this section, a commercial project includes multifamily residential developments larger than duplex. Site Plans submitted to the Building Official for commercial projects shall include: 1. Lot and block number; 2. Platted boundaries of the lot; 3. Exterior dimensions of lot drawn to scale; 4. Street address; 5. Zoning classification; 6. All setbacks; 7. Total number and location of off-street parking spaces provided; 8. Garbage dumpster location with a concrete pad; 9. Total area of lot and building; 10. All easements on the lot; 11. Location of curbs, on-premise signs, light-poles, adjacent street and public right-of-way lines, dimensions and locations of driveways, edge of roadway and parking layout, and location of storm sewer drainage systems; 12. A grading, drainage and erosion control plan with all pertinent topographic information on lot and surrounding lands; 13. Finished floor elevations; 14. Topographic contours taken from City GIS data, ground survey data or any other City approved contour data source; 15. Location of any designated floodplains or floodways within the boundaries of the lots; 16. Name, address, and phone number of the individuals responsible for the project; 17. Digital Site Plans shall be submitted to the Building Services Department. The Plans shall be drawn to scale in the scale shown; 18. Plans for all buildings with twenty-four (24) feet or more of clear span or five thousand (5,000) square feet shall be sealed with a registered engineer's seal; 19. The following retaining walls shall be designed and sealed by a Professional Engineer licensed to practice in the State of Texas: a. Any retaining wall(s) that supports a building, driveway or other permanent construction or imposed load that is located closer to the wall than one and one-half (1 ½) times the exposed height of the wall. b. Any retaining wall equal to or greater than four (4) feet high when measured from final grade to the top of the wall. c. A series of two or more walls built in tiers shall be considered a single wall in height when the base of the upper tier is set back from the base of the lower tier less than one and one-half (1 ½ ) times the height of the exposed wall height below. 20. Specify type of construction based on the current edition of the Building Code; 21. Elevation drawings indicating structure height; 22. Foundation drawings including beam and footing specifications; 23. Fire walls and draft stopping; 24. Location of building sprinkler and stand pipe systems, including fire flow requirements, location of building exits and exit lights, occupancy use, boiler rooms and heating system areas, fire alarm system, and fire hydrants; 25. Fire lane locations and markings; 26. All existing or planned utilities on the lot, including sanitary sewer manholes, fire hydrants, and size and location of service lines. (Ord. No. 0-97-29, 6-18-97) (Ord. No. 0-98-31, 4/15/98) (Ord. No. 0-2000-90, 11/15/00) (Ord. No. 0-2021-24; 3/24/21) (Ord. No. 0-2023-111;10/25/23)
Ask a question about Tyler law
Corpus searches the Tyler sections it holds and shows the ones that match, with their citations. Free, no sign-in.
