§ 13-811 — Grease interceptor cleaning/maintenance requirements
Official Code of the City of Clarksville (Supp. No. 110: codified through Ordinance No. 64-2025-26, enacted May 7, 2026) · Clarksville City Code § 13-811
Corpus is an independent public-information project, not the official City of Clarksville website. Stable reference: corpuslaw.us/code/bb7f5c7d-3d39-4fd7-a553-f809a82ce60e
Sec. 13-811. - Grease interceptor cleaning/maintenance requirements.
1. Partial pump of interceptor contents or on-site pump and treatment of interceptor contents will not be allowed due to reintroduction of fats, oils and grease to the interceptor and pursuant to city sewer use ordinance 88-2007-08, subsection 13-702(m) and as referenced in the Code of Federal Regulations (CFR) § 403.5 (b)(8), which states "Prohibited discharges. No persons shall discharge or cause or allow to be discharged or deposited into the City's wastewater system any wastewater that contains the following: Any trucked or hauled pollutants, except at discharge points designated and approved by the City." 2. Grease interceptors must be pumped-in-full (total pump of all contents) when the total accumulations of surface FOG (including floating solids) and settled solids reaches twenty-five (25) percent of the grease interceptor's overall liquid depth. This criterion is referred to as the "25 percent rule." at no time, shall the cleaning frequency exceed ninety (90) days unless approved by the city. Approval will be granted on a case by case situation with submittal by the FSE documenting proof of proposed frequency. Some existing FSEs in class 2 through 5 will need to consider a pumping schedule of thirty (30) days or sixty (60) days to meet this requirement. 3. The grease interceptor effluent-T will be inspected during cleaning and maintenance and the condition noted by the grease waste hauler's company or individual conducting the maintenance. Effluent-T's that are loose, defective, or not attached must be repaired or replaced immediately. Any repairs to the grease interceptor should be documented and kept on file at the FSE. 4. Grease interceptors must have access manholes over the influent-T and effluent-T for inspection and ease of cleaning/maintenance. Access manholes will be provided for all separate compartments of interceptors for complete cleaning (i.e. interceptor with two (2) main baffles or three (3) compartments will have access manholes at each compartment). 5. Grease interceptor waste must be hauled offsite and disposed at a state or POTW approved disposal location. 6. Grease interceptors must be "certified" annually by a grease waste hauler or plumber. Grease interceptor certification (form A) must be completed and submitted to city annually.
(Ord. No. 26-2008-09, 12-4-08)
Ask a question about Clarksville law
Corpus searches the Clarksville sections it holds and shows the ones that match, with their citations. Free, no sign-in.