§ 93.35 — Safe egress for dwellings other than rooming houses

Code of Ordinances, City of Dayton, Ohio (Supp. No. 36: codified through Ordinance No. 32173-25, passed December 31, 2025) · Dayton City Code § 93.35

Corpus is an independent public-information project, not the official City of Dayton website. Stable reference: corpuslaw.us/code/bcbb60e3-4a96-410a-bb11-fde78760ec3d

Sec. 93.35. - Safe egress for dwellings other than rooming houses.

(A) Where there is only one dwelling unit on the second story of a residential building, a single interior stairway may be accepted as the approved means of egress providing it exits into an approved front or side yard or other approved area and passage is not through the bathroom or a sleeping room of another dwelling or rooming unit to the exit door. Where there is more than one dwelling unit on a second story, or where there are more than two stories, a minimum of two approved exitways shall be provided to serve those dwelling units located above or below the first story. One of the required exitways shall be enclosed and exit into an approved front or side yard area. Passage to the required exitways shall not be through a habitable room of another dwelling unit, rooming unit, or bathroom. Exception: Two or more dwelling units on a second story may be served by a single stairway if such stairway is enclosed by one hour fire-resistant materials provided that the second story does not exceed 2,400 square feet in floor area and the distance from the dwelling units to the stairway does not exceed 50 feet. (B) Where a structure contains mixed occupancy composed of a dwelling unit and nonresidential use then the nonresidential use shall be separate from other portions of the building by construction affording a three-fourths hour fire rating and every dwelling unit above or below the first floor shall be provided with exitways as set forth in the uniform building code of the city. (C) Egress facilities of buildings or structures containing dwelling units constructed or altered to increase the use of occupancy on or after November 28, 1956, shall comply with the requirements of the uniform building code of the city.

(Ord. 18099, passed 11-10-54; Ord. 23095, passed 8-28-68)

Ask a question about Dayton law

Corpus searches the Dayton sections it holds and shows the ones that match, with their citations. Free, no sign-in.