Sec. 34-50. - Standards of construction.

In all special flood hazard areas the following standards are required: (a) Anchoring. (1) All new construction and substantial improvements shall be anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy; and (2) All manufactured homes shall meet the anchoring standards of section 34-54(b). (b) Construction materials and methods. (1) All new construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage; (2) All new construction and substantial improvements shall be constructed using methods and practices that minimize flood damage; and (3) Within zones AH or AO, adequate drainage paths shall be constructed around structures on slopes to guide floodwaters around and away from proposed structures. (c) Elevation and floodproofing. (1) Residential construction. Residential construction, new or substantial improvement, shall have the lowest floor, including basement elevated to or above the regulatory flood elevation: a. In a Zone AO, the base flood elevation is determined from the firm panel. If unspecified the required elevation is at a minimum two feet above the highest adjacent grade. b. In zones AE and AH, the base flood elevation is determined from the fis and/or firm. c. A garage attached to a residential structure, constructed with the garage floor slab below the regulatory flood elevation, must be designed to allow for the automatic entry and exit of flood waters and must be used solely for parking, access and/or storage. See section 34-50(c)(3). Upon completion of the structure, the elevation of the lowest floor including basement shall be certified by a registered professional engineer or surveyor, and verified by the community's floodplain administrator to be properly elevated. (2) Nonresidential construction. Nonresidential construction, new or substantial improvement, shall either be elevated to conform with section 34-50(c)(1) or together with attendant utility and sanitary facilities: a. Be floodproofed below the elevation recommended under section 34-50(c)(1) so that the structure is watertight with walls substantially impermeable to the passage of water; and b. Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. Upon completion of the structure, certification by a registered professional engineer or land surveyor that the elevation requirements of the lowest floor, including basement, of this section have been satisfied shall be provided to the floodplain administrator for verification; or certification by a registered professional engineer or architect that the floodproofing standards of this section are satisfied shall be provided to the floodplain administrator for verification. (3) Flood openings. All new construction and substantial improvement with fully enclosed areas below the lowest floor (excluding basements) that are usable solely for parking of vehicles, building access or storage, and which are subject to flooding, shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwater. Designs for meeting this requirement must meet or exceed the following criteria: a. For non-engineered openings: (i) Have a minimum of two openings, on different sides of each enclosed area, having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding; (ii) The bottom of all openings shall be no higher than one foot above grade; (iii) Openings may be equipped with screens, louvers, valves, or other coverings or devices provided that they permit the automatic entry and exit of floodwater; or b. For engineered openings: (i) Engineered openings (or covers and devices) that are specifically designed and certified by a registered engineer or architect as meeting the required performance and design requirements. (ii) Engineered openings (or covers and devices) for which an Evaluation Report has been issued by the International Code Council (ICC) Evaluation Service, Inc. (ICC-ES), a subsidiary of the International Code Council, Inc. (4) Manufactured homes. Manufactured homes shall also meet the standards in section 34-54. (5) Accessory structures (garages and storage structures). a. Used solely for parking (approximately 600 square feet or smaller) or limited storage (small, low-cost sheds), as defined in section 34-35, may be constructed such that its floor is below the regulatory flood elevation, provided the structure is designed and constructed in accordance with the following requirements: (i) Use of the accessory structure must be limited to parking of vehicles or storage; (ii) The portions of the accessory structure located below the regulatory flood elevation must be built using flood-resistant materials; (iii) The accessory structure must be adequately anchored to prevent flotation, collapse, and lateral movement; (iv) Any mechanical and utility equipment in the accessory structure must be elevated or floodproofed to or above the regulatory flood elevation; (v) The accessory structure must comply with floodplain encroachment provisions in section 34-56; and (vi) The accessory structure must be designed to allow for the automatic entry of floodwaters in accordance with section 34-50(c)(3). b. Detached garages, storage structures and other accessory structures not meeting the above standards must be constructed in accordance with all applicable standards in section 34-50. Upon completion of the structure, certification by a registered professional engineer or surveyor that the requirements of this section have been satisfied shall be provided to the floodplain administrator for verification. (d) Machinery and service equipment. All new construction, substantial improvement and other proposed new development that are constructed with electrical, heating, ventilation, plumbing and air conditioning equipment and other service facilities shall be designed and/or located to or above the regulatory flood elevation so as to prevent water from entering or accumulating within the components during conditions of flooding.

(Ord. No. 2879, § 1, 8-15-23)

Ask a question about Gilbert law

Corpus searches the Gilbert sections it holds and shows the ones that match, with their citations. Free, no sign-in.