§ 33.110.245 — Detached and Connected Accessory Structures
Portland City Code (non-zoning titles; Title 33 separately); partial · Portland Zoning Code § 33.110.245
Corpus is an independent public-information project, not the official City of Portland website. Stable reference: corpuslaw.us/code/bd8d359d-0381-44ad-8bc3-3c021f722fb1
33.110.245 Detached and Connected Accessory Structures
A. Purpose. This section regulates detached and connected structures that are incidental to primary buildings to prevent them from becoming the predominant element of the site. The standards limit the height and bulk of these structures, promote compatibility of design for larger structures, provide for necessary access around larger structures, help maintain privacy between abutting lots, and maintain open front setbacks. B. General standards. 1. The regulations of this section apply to detached accessory structures and connected accessory structures. Farm structures associated with an agricultural use such as barns and silos are exempt from these standards as long as they are set back from all lot lines at least one foot for every foot in height. Additional regulations for accessory dwelling units are stated in Chapter 33.205. 2. Detached accessory structures are allowed on a lot only in conjunction with a primary building and may not exist on a lot prior to the construction of the primary structure, except as allowed by Paragraph B.3. 3. A detached accessory structure that becomes the only structure on a lot as the result of a land division, a property line adjustment, a lot confirmation, or a demolition of the primary structure may remain on the lot if the owner has executed a covenant with the City that meets the requirements of Section 33.700.060. a. For a land division, the covenant must require the owner to remove the accessory structure if, within two years of final plat approval, a primary structure has not been built and received final inspection. The covenant must be executed with the City prior to final plat approval. b. For a property line adjustment or a lot confirmation, the covenant must require the owner to remove the accessory structure if a primary structure has not been built and received final inspection within two years. The two years begins on the date the letter from PP&D approving the property line adjustment or lot confirmation is mailed. The covenant must be executed with the City before the final letter from PP&D is issued. c. For a demolition of a primary structure, the covenant must require the owner to remove the accessory structure if a new primary structure has not been built and received final inspection within two years. The two years begins on the date of the final inspection of the demolition. The covenant must be executed with the City prior to the issuance of the demolition permit. C. Detached and connected covered accessory structures. The following standards apply to all detached covered accessory structures and connected covered accessory structures. Detached covered accessory structures are items such as garages, carports, greenhouses, artist’s studios, guest houses, accessory dwelling units, storage buildings, wood sheds, water collection cisterns, and covered decks or patios that are not connected to the primary structure. Connected covered accessory structures include accessory structures that are connected to a primary structure via a roofed structure such as a breezeway. The standards of this subsection do not apply to the portion of the structure that connects the accessory structure to the primary structure. Garages are also subject to the standards of 33.110.250. 1. Height. The maximum height allowed for all detached covered accessory structures and connected covered accessory structures is 20 feet. 2. Setbacks. Except as follows, detached covered accessory structures and connected covered accessory structures are subject to required building setbacks. See the additional regulations for garages in 33.110.250. a. Water collection cisterns that are 6 feet or less in height are allowed in required side and rear setbacks. b. In the R7, R5 and R2.5 zones, detached covered accessory structures other than water collection cisterns, are allowed in required side and rear building setbacks if all of the following are met: (1) The structure is at least 40 feet from a front lot line, and if on a corner lot, is at least 20 feet from a side street lot line; (2) The structure’s footprint has dimensions that do not exceed 24 feet by 24 feet, excluding eaves; (3) If more than one structure is within the setback, the combined length of all structures in the setback adjacent to each property line is no more than 24 feet; (4) The structure is no more than 15 feet high, and the walls of the structure are no more than 10 feet high, excluding the portion of the wall within a gable; (5) The portion of the structure within the setback must be screened from adjoining lots by a fence, unless it is enclosed within the setback by a wall. Screening is not required for enclosed structures. Screening must comply with the F2 standards of Chapter 33.248, Landscaping and Screening; (6) Walls located within the setback do not have doors or windows facing the adjacent lot line; (7) The structure does not have a rooftop deck; and (8) Dormers are set back at least 5 feet from the side and rear lot lines that abut another lot. 3. Building coverage. The following additional building coverage standards apply to detached covered accessory structures and connected covered accessory structures: a. The combined building coverage of all detached and connected covered accessory structures may not exceed 20 percent of the total area of the site; and b. The building coverage of each detached covered accessory structure and each connected covered accessory structure may not be greater than the building coverage of the smallest primary structure, or 900 square feet, whichever is greater. 4. Additional development standards. The following additional standards apply to detached covered accessory structures and connected covered accessory structures that are more than 15 feet high. Additions to existing structures that do not meet a standard are exempt from that standard. a. Exterior finish materials. The exterior finish materials must meet one of the following: (1) The exterior finish material must be the same in type, size and placement as the exterior finish material of a primary structure; or (2) Siding must be made from wood, composite boards, vinyl or aluminum products, and the siding must be composed in a shingle pattern, or in a horizontal clapboard or shiplap pattern. The boards in the pattern must be 6 inches or less in width. b. Roof Pitch. The pitch of the roof with the highest ridgeline must meet one of the following: (1) The pitch of the roof with the highest ridgeline must be the same as the pitch of the roof with the highest ridgeline of a primary structure; or (2) The pitch of the roof with the highest ridgeline must be at least 6/12. c. Trim. The trim must meet one of the following: (1) The trim must be the same in type, size, and location as the trim used on a primary structure; or (2) The trim around all windows and doors must be at least 3 ½ inches wide. d. Windows. The windows on all street facing facades must meet one of the following: (1) The windows must match those on the street facing facade of a primary structure in orientation (horizontal or vertical); or (2) Each window must be square or vertical – at least as tall as it is wide. e. Eaves. The eaves must meet one of the following: (1) The eaves must project from the building walls the same distance as the eaves on a primary structure; (2) The eaves must project from the building walls at least 1 foot on all elevations; or (3) If the primary structure has no eaves, no eaves are required. D. Detached uncovered vertical structures. Detached uncovered vertical structures are items such as flag poles, trellises, arbors and other garden structures, play structures, antennas, satellite receiving dishes, detached structures that hold electric vehicle chargers, and lamp posts. The following standards apply to detached uncovered vertical structures. Fences are addressed in 33.110.275: 1. Height. Except as follows, the maximum height allowed for all detached uncovered vertical structures is 20 feet: a. Antennas, utility power poles, and public safety facilities are exempt from the height limit. b. Flagpoles are subject to the height limit of the base zone for primary structures. c. Detached small wind turbines are subject to the standards of 33.299, Wind Turbines. 2. Setbacks. Except as follows, detached uncovered vertical structures are subject to required building setbacks: a. Detached uncovered vertical structures that are no larger than 3 feet in width, depth, or diameter and no taller than 8 feet are allowed in required building setbacks. b. A single arbor structure that is up to 6 feet wide, up to 3 feet deep, and up to 8 feet tall is allowed in the front setback. The arbor must allow for pedestrian access under its span. c. Flagpoles are allowed in required building setbacks. d. In the R7, R5, and R2.5 zones, detached uncovered vertical structures that exceed the allowances of Subparagraph 2.a are allowed in side and rear setbacks if all of the following are met: (1) The structure is at least 40 feet from a front lot line, and if on a corner lot, at least 20 feet from a side street lot line; (2) The structure’s footprint has dimensions that do not exceed 24 feet by 24 feet; (3) The structure is no more than 10 feet high; (4) The portion of the structure within the setback must be screened from adjoining lots by a fence or landscaping, unless it is enclosed within the setback by a wall. Screening is not required for enclosed structures. Screening must comply with the L3 or F2 standards of Chapter 33.248, Landscaping and Screening; and (5) The structure does not have a rooftop deck. 3. Additional standard for detached uncovered vertical structures that hold electric vehicle chargers. In addition to Paragraphs 1. and 2. above, a detached uncovered vertical structure that holds at least a Level 2 electric vehicle charger must be located so that the electric vehicle charger is within 5 feet of a vehicle area. E. Detached uncovered horizontal structures. Uncovered horizontal structures are items such as decks, stairways, swimming pools, hot tubs, tennis courts, and boat docks not covered or enclosed. The following standards apply to detached uncovered horizontal structures. 1. Height. The maximum height allowed for all detached uncovered horizontal structures is 20 feet. 2. Setbacks. Except as follows, detached uncovered horizontal structures are subject to required buildings setbacks: a. Detached uncovered decks, ramps, and stairways that are more than 2-1/2 feet above the ground may extend into a required building setback up to 20 percent of the depth of the setback. However, the deck or stairway must be at least three feet from a lot line. b. Structures that are no more than 2-1/2 feet above the ground are allowed in required building setbacks. F. Detached mechanical equipment. Detached mechanical equipment includes items such as heat pumps, air conditioners, emergency generators, radon mitigation components, and water pumps. Generally, detached mechanical equipment will not be attached to a building but may have components such as ventilation or electrical systems attached to the primary structure. The following standards apply to detached mechanical equipment: 1. Height. The maximum height allowed for all detached mechanical equipment is 20 feet. 2. Setbacks. Except as follows, detached mechanical equipment is subject to required building setbacks. Detached mechanical equipment is allowed in side or rear building setbacks if the equipment is no more than 5 feet in height, width, or depth.
Ask a question about Portland law
Corpus searches the Portland sections it holds and shows the ones that match, with their citations. Free, no sign-in.
