Sec. 62.499. - SODO Special Plan.
a) Relationship to Growth Management Plan. The Growth Management Plan (GMP) calls for an Urban Design Plan for the S. Orange Avenue/Michigan Street corridors and performance standards for mixed-use corridors in the Traditional City (Urban Design Element Goal 2, Objective 2.1, and Policy 2.1.4, and Goal 4, Objective 4.1, and Policy 4.1.1.). This Special Plan implements the recommendations from the Urban Design Plan, and its update called the SODO District Development Standards and Design Guidelines and establishes performance standards.
b) Objectives. The overall purpose of the SODO Special Plan is to provide a vibrant, recognizable, mixed-use, multi-modal neighborhood that thrives on the synergies afforded by the continued growth of the Orlando Health campus and related medical uses, and the continued success of the SODO Main Street District. The primary goals of this Special Plan is to preserve and strengthen commercial activities and redevelopment opportunities within the area, enhance pedestrian safety and main street character, and protect existing residential neighborhoods from encroachment.
The specific objectives of this Special Plan are to:
1) Facilitate infill development and guide future growth while protecting the existing residential neighborhoods within and adjacent to the district.
2) Encourage design diversity and variation, while ensuring a compact and dense urban form concentrated on the west side of Orange Avenue corridor with a gradual transition to less dense residential neighborhoods to the east of the Orange Avenue corridor.
c) Application. The standards of this Special Plan shall apply to the area within the City of Orlando depicted in Figure 1. This is a transect-based special plan, and standards vary by transect zone. Each transect is described in detail in section (e) and is shown in Figure 1.
d) Support Document. The standards of this Special Plan are intended to implement the recommendations provided in the Orange/Michigan Vision Plan Support Document (May 2010), SODO Complete Streets Master Plan, and the SODO District Development Standards and Design Guidelines (September 2018). These support documents shall provide the basis for clarifying the intent of the regulations contained in this Section, and shall serve as a guideline for the review of discretionary land use permits by the Development Review Committee (DRC). These documents may be amended from time to time through the Municipal Planning Board.
e) Precise Plan Transitions and Transect Standards. Through this special plan a transect based planning approach has been utilized for those properties located within the special plan boundaries. The transects described below as well as the related standards of this special plan are intended to supplement the Land Development Code acknowledging the transitional nature of the SODO district and to provide additional flexibility through the course of the district.
The following transition areas ("Transects"), as depicted on the Transect Map (Figure 1) and further described below, are hereby created:
1) T3: Suburban Transect. This area represents existing low-density residential neighborhoods with predominately single-family and duplex homes. Accessory Dwelling Units are also encouraged. Default zoning district standards shall continue to apply, and requests for re-zonings to allow additional intensity or change the residential character of these areas are discouraged.
2) T3.5: Live/Work Transect. This intermediate transition area is intended to allow for a mix of townhomes, attached or semi-detached residential buildings (1-4 dwelling units typical), offices, and residential-office mixed use buildings that are rear-loaded, designed to appear residential from adjacent residential streets, and accessed from adjacent T4 properties. Up to 0.30 FAR of office uses may be allowed in residential zoning districts when permitted by relevant Growth Management subarea policies and approved by the DRC. This is primarily a residential transect, retail, restaurant, personal service, and other commercial uses are not permitted. T3.5 properties are encouraged to be consolidated with abutting properties facing commercial corridors (particularly S. Orange Avenue, E. Michigan Street, E. Pineloch Avenue, and W. Grant Street) whenever feasible.
3) T4: General Urban Transect. This transect is the "main street" transect and is intended to promote a mix of commercial, office, residential, and mixed-use buildings that are appropriately scaled to the main street area. Buildings are typically 1-3 stories. Horizontal mixed-uses (side by side in one or more buildings) shall be allowed, but vertical mixed-uses (upper floors have a different use than the ground floor) are preferred.
4) T5: Urban Center Transect. The primary intent of this zone is to create a vibrant mixed-use place for residents and visitors alike that is pedestrian-oriented and provides opportunities for a mixture of compatible land uses such as residential, commercial, retail, office, and entertainment uses. The design of sites in the T-5 Zone should allow residents and visitors to walk between shops and buildings by creating an internal, pedestrian-oriented street network; off-street parking shall be located behind the buildings and supplemented with on-street parking. While vertical mixed-uses are preferred, horizontal mixed-uses and single-use commercial, office or residential buildings shall be allowed if they are designed to conform to the urban form designated for this area. Open space within this Zone shall be provided in the form of amenity areas and public plazas that are urban in character.
It is important to accommodate public transit users, as well as bicycles and pedestrians traveling along the corridor. Ground-floor commercial uses are encouraged to contribute positively to a pedestrian-friendly environment, but frontages may also be occupied by other uses such as hotels, multifamily, public or office uses. Buildings are to be located close to the street but still allow ample room for pedestrian activity, public gathering spaces and safety. Development in the T-5 zone is still intensive but in a lesser degree than the T-6 zone, serving as a transition between the tallest and most intensive development around the train station and the hospital and the residential neighborhoods south of Michigan Street and east of Orange Avenue.
5) T6: Urban Core Transect. The primary intent of this zone is to allow redevelopment to create a vibrant, transit-oriented neighborhood with a mix of residential, retail and office uses while continuing to allow the type of industrial activities that have resided in this area for many years. This zone will focus on allowing high intensity development that supports public transit users as well as bicycle and pedestrian activity. The T-6 zone is also intended to accommodate uses that typically locate close to a hospital.
Ground-floor commercial uses are encouraged to generate activity and contribute positively to a pedestrian-friendly environment, but frontages may also be occupied by other uses such as hotels, multifamily, public or office uses. Buildings are to be placed close to the street, but exceptions are provided to accommodate outdoor gathering spaces (e.g. public plazas, outdoor dining) as well as pedestrian activity and safety. Off-street parking shall be located behind the buildings or in covered garages.
The Kaley Street/Division Avenue node is intended to become a highly visible and memorable node of activity representing the western gateway to the SODO district. The area to the north of this gateway is intended to promote a complementary mixture of transit-supportive uses at higher densities and intensities within walking distance of the SunRail station.
Development density, intensity and height is the most intensive in this area, given the presence of the SunRail station within the zone, and its location between the Interstate (I-4) on the west and already intensive hospital uses on the east side.
FIGURE 1—SODO TRANSECT ZONES
[image omitted; see the official code]
f) Land Use Standards.
1) Alternative Uses: The permitted and conditional uses within the SODO district shall be as specified for the underlying zoning district per LDC CH 58 Sec. 1B. However, the alternative uses listed below may be approved through a formal review either through a Master Plan to the DRC for (P) uses or a Conditional Use Permit to the Municipal Planning Board for (C) uses, provided that the use is consistent with the Future Land Use designation of the site. Whenever there is any uncertainty as to the classification of a use, the Zoning Official shall determine the classification.
Figure 2—Alternative Uses
USES | T-3 | T-3.5 | T-4 | T-5 | T-6
RESIDENTIAL (3)
Townhomes | P | P | P | P | P
Single Family | P | P | P
Duplex or Tandem | P | P | P
Live-Work Unit (4) | P | P | P | P | P
Multi-Family | C (1) | P | P | P | P
NON-RESIDENTIAL
Child/Adult Day Care | C | P | P
Drive-through Facilities | C | C | C
Eating and Drinking | P | P | P
Hospitals/Clinics | C | P | P
Hotels/Motels | P | P | P
Manufacturing/Processing (2) | C | C | C
Office, Medical Office, Medical/Dental Labs | P | P | P | P
Recreation, Outdoor | C | C | C
Recreation, Indoor | C | P | P
Retailing Light | P | P | P
Retailing Intensive | C | C
Services Personal | P | P | P
Services Intensive (2) | C | C
Services Major Vehicle (2) | P | P
Services Automotive | P | P
Warehouse/Showroom (2) | P | P | P
Wholesale/Warehouse (2) | P | P | P
P = Permitted; C = Conditional Use
FOOTNOTES
1. Limited to 5 units per building
2. Only if the Future Land Use of the site is Industrial.
3. Residential, as detailed in the table above, permitted in all transects with a FLU of Industrial per Sub Area Policy S.12.7
4. For purposes of this special plan Live/Work is defined as units that include a complete dwelling unit with kitchen and bathroom, as well as space suitable for running a business, provided that the business is a permitted or lawfully approved conditional use in the zoning district.
g) Density/Intensity Bonuses. Developments in the SODO district may be eligible for building height and/or intensity/density bonuses as follows.
1) Maximum Available Bonus.
a. This section is applicable in lieu of meeting the standards of Chapter 58, Parts 6B or 6D.
b. Development projects within the SODO district that meet all the standards contained in this document may be eligible to achieve the additional density and/or intensity noted below and the additional building height listed in Table 4 through the Master Plan process. Additional residential density may be approved by Master Plan in the industrial zoning districts.
c. Density bonuses within the T-3.5 zone may only be approved when the additional units will be retained as Low and Very-Low Income Housing units within an otherwise market-rate development.
d. No bonus shall be approved that increases the building mass beyond what would otherwise be allowed.
e. Developments utilizing the bonus system shall not have any buildings located within 100 feet of a single-family residentially-zoned property.
Figure 3—Bonus Areas
Geographical Area (per GMP Subarea Policy area noted below) | Max. Development Density with Bonus (units per acre) | Max. Development Intensity with Bonus (Floor Area Ratio)
S.12.7 (General) | 40 | 1
S.12.8 (Kaley Gateway) | 100 | 2
S.12.9 (Transit 1) | 100 | 1.6
S.12.9.1 (Transit 2) | 100 | 3
h) Building Typology. Form-based regulations use physical form, rather than separation of land uses, as the organizing principle of a community. Buildings within the SODO district shall adopt one of the following building typologies based on the location of the property within one of the transect zones (Figure 4). The typologies do not necessarily refer to the use of the building, but rather to character of it.
Figure 4—Building Typologies
Building Typology (1) (2) | T-3 | T-3.5 | T-4 | T-5 | T-6
Mixed-Use | X | X | X
Single Use Non-Residential | X | X | X
Single Use Multi-Family | X | X | X
Live-Work | X
Single-Family | X | X
Civic | X | X | X | X | X
FOOTNOTES
(1) Additional information on building Typology and examples of each may be found in the SODO Development Standards and Guidelines document.
(2) Industrial Buildings are permitted in those areas where the underlying zoning permits Industrial uses; where possible a building typology mirroring those outlined in the table above should be utilized.
i) Building Setbacks, Height and Impervious Surface Ratio. Most Land Development Standards within the SODO district are based on what Transect Zone the property under development is contained within. Figure 5 includes standards specific to setbacks, height and ISR, this figure supersedes any standards also listed in Chapter 58, Figures 1 and 2.
Figure 5—Transect Development Standards
Standards (6) | T-3 | T-3.5 | T-4 | T-5 | T-6
Front and Street Side Setbacks (1) (2) | Min | 15 | 15 | 7 | 7 | 7
Max | 15 | 15 | 15
Side Setback (3) (4) | Min | 5 | 5 | 0 | 0 | 0
Min Single Family Zoning | 20
Max | FN (3) | FN (3) | FN (3)
Rear Setback | Min | 15 | 15 | 10 20 (if single-family) | 10 | 10
Min With Alley | 3 | 3 | 3
Building step Back Next to Single Family Zoning (5) | 10 ft. for each floor above 2. | 10 ft. for each floor above 2.
Impervious Surface Ratio (max.) | 0.6 | 0.6 | 0.9 | 0.9 | 0.9
Building Height (8) | Min | 20 | 20 | 20
Max | 2.5 stories | 2.5 stories | 3 stories | 5 stories | 9 stories (120 ft.)
Max w/Bonus (7) | 4 stories (S of Michigan) | 17 stories (200 ft.)
Floor Height | Ground Floor Min (9) | 8 ft. res./12 ft. non- res. | 8 ft. res./12 ft. non- res. | 10 ft. res./12 ft. non- res. | 10 ft. res./12 ft. non- res. | 10 ft. res./12 ft. non- res.
Upper Floors Min | 8 | 8 | 8 | 8 | 8
FOOTNOTES
(1) Front and Street Side Setbacks are measured from the back of the Streetscape Zone (see k). A maximum of 30 percent of the primary building facade may be permitted to encroach up to 7 feet into the required front and/or street side setback via board action, but may not encroach into the streetscape zone.
(2) Awnings/Marquees meeting the requirements of the special plan and Code may project up to eight (8) feet into the street setback and must meet the requirements of LDC Sec. 61.204.
(3) See Section J Building Frontage.
(4) Whenever a new building is being built adjacent to a building that has a zero-foot side yard setback, and a zero foot setback is allowed by the T-zone, the new building shall either have a zero-foot setback or provide a minimum side yard setback of seven and one-half (7.5) feet.
(5) See Section I.9, Site Setback/Building Frontage.
(6) The minimum setback for all buildings adjacent to the railroad right-of-way is 7.5 ft.
(7) All height bonus requests must be included in a full Master Plan or Conditional Use Permit submittal.
(8) Decorative elements such as spires, minarets, clock towers, and cupolas are allowed over the maximum number of stories as long as they do not exceed 20% of the proposed building height.
1) Building step Back Next to Single Family Zoning.
a. For each building proposed to be three (3) stories or more in T-4 and T-5 zones, an additional building setback of ten (10) feet over the minimum required shall apply to each façade that faces the side or rear property line of an abutting single family residentially-zoned or T-3 and T-3.5 property. The additional setback may be provided in one of three ways:
(1) Apply the setback only to those floors above the second story
(2) Apply the additional setback requirement to the entire façade.
(3) Or a combination of the first two options.
2) Floor Height: The following standards shall be used when calculating the number of floors in accordance with the maximum number of stories within the SODO Special Plan Area.
a. Floor height shall be measured as the clear height from finished floor to finished ceiling.
b. Whenever a ground floor level exceeds twenty (20) feet in height, each height of twelve (12) feet or portion thereof shall be construed to be one (1) story.
c. Whenever a floor other than a ground floor exceeds twelve (12) feet in height, each height of twelve (12) feet or portion thereof shall be construed to be one (1) story.
d. Mezzanines extending beyond 33% of the floor area shall be counted as an additional story.
e. Parking garages are exempt from the floor height requirements but are subject to maximum number of stories and maximum height.
f. The first floor of residential buildings shall be elevated above the finished grade adjacent to the building. The building should incorporate either a raised concrete pad or a raised wood joist floor with perimeter foundation at a minimum of eighteen (18) inches above the finished grade.
j) Building Frontage Requirements.
1) The building frontage standards are stated as a proportion of the building width (within the required building setback) relative to the width of the development site measured at the site frontage line. Portions of the building façade outside the required building setbacks do not count as building frontage.
2) The minimum required building frontage varies based on the transect zone, building type and street type. The requirements are as follows:
Figure 6—Building frontage Requirements
T-3/T-3.5 | T-4 | T-5 | T-6
Primary Street
Mixed-Use, Single Use | NA | 65% | 70% | 70%
Live-Work, Single Family | 40% | NA | NA | NA
Civic, Industrial | 40% | 40% | 40% | 40%
Secondary Streets
Mixed-Use, Single Use | NA | 50% | 50% | 50%
Live-Work, Single Family | 20% | NA | NA | NA
Civic, Industrial | 40% | 40% | 40% | 40%
3) Building facades facing a right-of-way shall be built predominantly orthogonal (parallel) to the street.
4) Unless explicitly exempted below, all buildings and development sites within the Special Plan are subject to the Building Frontage requirements listed in Figure 6 including drive through facilities.
5) Exceptions to the Building Frontage requirements:
a. In the case where the required building frontage cannot be met due to the need to provide vehicular access from the street, a gateway, arch, or similar feature shall be provided to preserve the block continuity and may be counted toward meeting the building frontage requirement.
b. Single family, duplex, townhomes, Public Assembly PBU uses are not subject to the minimum frontage requirements.
k) Street Setback Zone adjacent to Orange Avenue and Michigan Street.
1) Building facades shall be located no less than 20 feet from the back-of-curb to the primary building facade. Maximum setbacks shall continue to apply as required as shown in Figure 5. The 20 feet street setback zone shall be provided as follows:
a. 13-foot Streetscape. From back of curb, 6 feet shall be utilized for a park strip (typical for Michigan Street) or tree well area (typical for Orange Avenue). A 7 foot sidewalk shall be installed adjacent to the 6 foot park strip or tree well area. Where the existing right-of-way is less than 13 feet, the owner shall dedicate additional City Services Easements to provide a total of 13 feet for city services and sidewalk from the back-of-curb. Modifications to the placement of the sidewalk and park strip may be required by FDOT and/or the City Engineer; however, in no case shall less than 13 feet from back-of-curb be provided.
b. 7-foot courtyard. The remaining 7 feet is a minimum ground floor building setback, shall not require additional easement dedication, and must include landscaping. See below for specific allowances and requirements for the courtyard areas created by this required building setback. Modifications and variances to this setback may be allowed in accordance with Chapter 65, Part 2J.
2) Should any part of the street setback zone fall within private property an easement will be required over that area.
3) Street furniture such as benches, trash receptacles, and/or bicycle racks may be installed within the Street Setback Zone, provided the 7 foot sidewalk remains clear.
4) Outdoor dining is permitted within street setback zones as long as restaurants are a permitted use and the 7 foot sidewalk remains clear.
5) The Street Setback Zone may be used to accommodate grade changes necessary to direct stormwater to the back of the site, and /or necessary to access the building which may be at a different grade than the public sidewalk. Grading may be achieved with landscaping, steps, elevated platforms, stairs, or other treatment.
l) Site Design Standards.
1) Site Access and Circulation.
a. Cross Access. Cross access easements and unified access and circulation must be provided unless the Planning Official, in coordination with the Public Works Director, determines that it is either technically impractical to provide such accommodation or that the providing of cross access easements and unified access and circulation would have a harmful impact to adjacent properties or streets.
b. Vehicular Site Access. New curb-cuts to Orange Avenue and Michigan Street are discouraged, and are not allowed when a development site has ingress/egress locations available to side streets. Ideally, only one curb-cut at the mid-point of each block shall be allowed, except where this requirement results in unsafe or inefficient site circulation.
c. Surface and structure parking areas shall be accessed from a secondary street, from an adjacent property (joint access easement and shared use agreement necessary), or from rear alleys if any of these are available or proposed as part of the development. Access through single family residential neighborhoods, however, shall not be allowed.
d. Direct pedestrian access shall be provided from the principal entrance of the building to the sidewalk on the closest public right-of-way.
2) Surface Parking Location and Screening.
a. Surface parking lots shall be located behind buildings so that the parking areas are screened from public sidewalks and streets consistent with Traditional City Design standards.
b. Where a site is too shallow to provide parking behind the building, the placement of parking facilities and vehicular driveways is permitted on the side of the proposed building only if the building setback requirements are met and a modification of standards for the minimum building frontage (if necessary to accommodate the parking area) is approved. The vehicular areas shall be screened from the road by a street wall (see Section L.3). Design conflicts between vehicular and pedestrian movement generally shall be decided in favor of the design which promotes pedestrian circulation.
c. Any surface parking areas located along a public street shall be screened from street view by a street wall (see Section L.3).
d. On-street parking directly in front of the site may be counted toward the minimum required parking, but only if the parking spaces were created as part of the development or redevelopment of the site.
e. A Bufferyard B, to include a solid masonry wall, is provided between any parking or vehicular use area and any directly adjacent residential lot.
f. A surface parking lot for a commercial or multi-family development may be permitted on T3.5 lots as part of a broader consolidated development site that also includes T4 lots when the Zoning Official determines that the consolidated site plan provides a logical transition to the adjacent residential neighborhood. All surface parking must be rear loaded where possible or accessed from the T4 property.
3) Street wall Design Standards.
a. Street walls as required to screen parking lots or other vehicular use areas as detailed in this Special Plan must meet the following requirements.
b. The wall shall be a minimum of three (3) feet and a maximum of four (4) feet in height. The portion of the wall above three (3) feet shall be no more than fifty (50) percent solid.
c. Street walls shall be constructed of brick, masonry, stone, powder-coated aluminum or other decorative materials that complement the finish on the primary building. Wrought iron may be used for the portion of the wall between three (3) and four (4) feet in height. Chain link, wood and PVC street walls shall be prohibited.
d. When a parking lot abuts a public right-of-way, ground cover, hedges, or shrubs shall be installed on both sides of the wall. The landscaping strips shall be a minimum of three (3) feet wide. The area in front of a street wall may be landscaped or used to expand the public sidewalk.
e. Breaks along the street wall are required to provide pedestrian access to the site.
f. Street walls may be interrupted for the purpose of tree protection.
g. Crime Prevention Through Environmental Design (CPTED) design guidelines should be incorporated in the final design and placement of the wall and adjacent landscaping.
m) Stormwater Design Standards: Intent. The properties located along S. Orange Avenue have historically had difficulties meeting engineering standards for stormwater retention and quality within the constraints of a dense, traditional urban fabric due to the low elevation of S. Orange Avenue, the relatively low elevation of the entire area, and the relatively high water table in the area within the context of a large flood plain. In order to maintain positive design elements and encourage context-sensitive redevelopment, the following requirements for storm water design shall be met. Nothing in this section shall exempt the applicant from meeting all requirements of the state, water management district, or other governing body for water quality standards.
1) If a master stormwater system is available to the site, the developer shall connect to that system, rather than provide on-site facilities. Existing on-site ponds on redevelopment sites shall be removed and connection to the master system shall be required.
2) If a pond is proposed, and the slopes require fencing, only ornamental metal fencing will be allowed.
3) A master drainage plan shall be included in all master plan, conditional use, or planned development applications where above ground stormwater areas are proposed as part of the development. The purpose of the Master Drainage Plan and site and building section drawings is to clearly show the relationship of the stormwater systems and necessary site grading to the buildings, sidewalks, ramps, parking areas, outdoor dining areas, landscaping, and other site design elements
4) T-4, T-5, T-6: The following techniques shall be utilized when designing stormwater systems for T-4, T-5, and T-6 lots:
a. Where site grading is required, the resulting finished floor elevation shall be sensitively integrated into the design of the site using appropriate landscaping, building design, or active uses that can be appropriately elevated 1 to 3 steps above the sidewalk grade such as outdoor dining spaces. No steps or railings shall be permitted to encroach within a sidewalk, public right-of-way, or city services easement.
b. All stormwater systems shall be designed to function as site amenities, or exfiltration shall be required. Green roofs, rain gardens, rain cisterns, or other green or low impact design stormwater techniques may be considered site amenities for the purpose of this requirement.
c. To reduce the size of stormwater ponds, the use of porous concrete, pave drain systems, underground storage, and exfiltration is greatly encouraged. Each of these options may increase the amount of developable land or undisturbed open space.
5) The following techniques shall be utilized when designing surface stormwater systems for T-3.5 lots:
a. Must be designed with the appearance of a pocket park, with creative use of grading, retaining walls, swales, and landscaping to create a park-like appearance.
b. Slopes should be less than 4:1.
c. No gravel bottoms are allowed, they must be landscaped.
d. Litter management is required.
e. Solid walls may be used to support grading or to screen parking areas from neighborhoods. All other fencing must be CPTED-style open metal fencing. Chain link fencing is prohibited.
6) T-3 Zones: Stormwater facilities in T-3 zones are only allowed to support uses in other T zones with frontage on Orange Avenue or Michigan Street. The T-3 lot must be consolidated with a T-4 (or higher) lot as a single development site, and a Bufferyard B, to include a solid masonry wall, must be provided between the stormwater area and any directly adjacent residential lot.
n) Building Design Standards: All standards below must be met. The SODO Development Standards and Guidelines document provides additional examples and details.
1) Building Entrance: The main entrance of all buildings shall be oriented toward the public right-of-way.
2) Active ground floor use: At least 51% of the ground floor street frontage shall be an active use.
3) Parapets shall be three dimensional and shall incorporate a minimum return of six (6) feet.
4) Cornices shall be expressed with greater than flashing or minimal materials.
5) Windows and Doors/Transparency: The arrangement of windows and doors on new buildings varies depending on the building typology and the transect zone where it is located. Buildings in the T-4, T-5 and T-6 zones must be consistent with the main street typical pattern of windows and doors, which includes storefront-type openings on the first floor and smaller openings on the upper stories. Buildings in the T-3.5 and T-3 zones are more residential in character and do not need to provide as much transparency. Development in all transects shall meet the following standards:
a. Non-Residential/Mixed Use First Floor: In the T-4, T-5 and T-6 zones, the area of the façade from three (3) feet to seven (7) feet above grade shall have no less than 30% of that area dedicated to transparency.
b. Non-Residential/Mixed Use Upper Floors: The combined area of glass on all upper floors divided by the total area of the building facade for those floors shall be no less than 15%.
c. Residential: Buildings in the T-3.5 and T-3 zones are more residential in character but must provide no less than 15% transparency.
d. Windows and doors should be glazed in clear glass with no more than ten (10) percent daylight reduction (transmittance) for retail establishments, and fifty (50) percent for office and residential uses. Glass block is not considered transparent and shall not count toward the minimum transparency requirement.
e. Reflectance, the amount of light reflected off of the glass, shall not exceed fifteen (15) percent.
6) Building Articulation: Building frontages on all streets shall be articulated as shown in Figure 7. The purpose of this requirement is to make buildings appear as multiple smaller volumes grouped together. This can be achieved through variation of building height and width dividing volumes into distinct massing elements. In no event shall buildings exceed a height to width ratio of 1:3 or the length noted in the table, whichever is less, without providing a substantial volume break, which may consist of a projection or recess, a tower or bay, and/or an architecturally prominent entrance. These vertical and horizontal projections and recesses shall have a minimum depth as noted in Figure 7.
Figure 7—Required Building Articulation
T-3/T-3.5 | T-4 | T-5 | T-6
Max. Building Length/Width/Depth | 75 ft. | NA | NA | NA
Articulation Spacing | 30 ft. | 60 ft. | 120 ft. | 120 ft.
Projection/Recess Depth | 2 ft. | 3 ft. | 3 ft. | 3 ft.
7) Structured Parking Design Standards: The following standards are provided to ensure that structured parking is not simply viewed as an add-on to a development site but rather an integral part of the overall design and intent for a building site.
a. Parking structures facing Primary Streets (as depicted in Figure 9) shall be placed behind a liner building that houses active uses.
(1) If the parking garage has more than one story and the building is located along a primary street, the liner building shall be at least two (2) stories in height and twenty (20) feet in depth.
(2) The liner building shall house active uses (e.g. commercial, office, residential) along the first floor facing the public right-of-way.
(3) The liner building shall extend for a minimum of seventy-five (75) percent of the length of the parking structure facing the primary public right-of-way.
(4) The liner building may be attached to or detached from the principal building they are concealing and may be in front of the parking structure or imbedded into the façade.
(5) Pedestrian access to the interior of the parking structure shall be provided by the most direct means to the street or principal use as possible in a safe, well lit pathway.
b. Liner buildings are not required along other streets. However, any portion of a parking garage that is not concealed behind a building shall be screened to conceal all internal elements such as plumbing pipes, fans, ducts and lighting and incorporate architectural treatments of the principal building.
c. Ramping shall be internalized. Exposed spandrels shall be prohibited unless architecturally integrated into the overall design of the garage.
d. The first floor of all parking garages not located behind a liner building must contain a minimum 1 st floor height of 16 ft. to accommodate possible conversion to an active use in the future.
e. Parking garages not concealed behind liner buildings or active uses (e.g. commercial, office, residential) shall provide landscaping in accordance with LDC Sec. 61.315.
f. The exterior facades of all parking garages shall be designed as to achieve architectural unity with the principal structure(s) which they are intended to serve. The quality of design and use of material must be on par with those used in the principal structure.
g. Parking structures shall meet the same setback, height, façade articulation and Transparency standards as habitable buildings.
o) Number of Parking Spaces.
1) Single-Use Development: Off-street parking for developments that propose only one type of land use shall provide the number of spaces required per LDC Chapter 61, Part 3C.
2) Mixed Use Development: Off-street parking for developments that propose two or more uses shall provide the number of spaces required per LDC Chapter 61, Part 3C. The maximum amount of parking allowed shall be divided by the appropriate factor from the Sharing Factor matrix as shown in Figure 8. When more than two uses share parking, the lowest number shall be used.
Figure 8—Shared Parking Matrix
[image omitted; see the official code]
p) Signage: Signage within the SODO Special Plan boundaries shall comply with the sign standards of this section in addition to the dimensional standards contained in Chapter 64 of the Land Development Code. If any sign standards in this document are in disagreement with the citywide sign code, the standards detailed in this document shall take precedence.
1) Building Signs.
a. Office Uses in T-3.5 zone are permitted a single building sign subject to the following restrictions.
(1) One tenant: Four (4) square feet
(2) Two to three tenants: Six (6) square feet
(3) Four tenants or more: Eight (8) square feet
b. Individual businesses in all other zones shall be allowed up to two (2) building signs per business frontage as follows:
(1) Types of Signs Allowed.
i. Wall Sign.
ii. Projecting/Blade Signs.
iii. Marquee Sign.
iv. Awning Sign.
v. Hanging Sign.
vi. Window Sign.
vii. Roof Sign.
viii. 3-D Signs.
(2) Building Sign Standards. Building signs must comply with the standards of Chapter 64, with the exception of the following:
i. Wall signs shall be either a panel or individual letters applied to the wall, shall not extend above the top of the wall where it is located, and in the case of two story buildings, it shall be placed between the first and second floor windows. Cabinet signs and signs painted directly onto the façade are not allowed. Push Through signs, however, are allowed.
ii. Wall signs shall not extend closer than two (2) feet to the side edges of the façade.
iii. Wall signs shall be permitted above the second story provided they are attached flat against the building wall and placed on the top floor of the building (see Figure 67). If they are located above thirty (30) from the ground, they shall conform to the high-rise or mid-rise sign regulations as applicable.
iv. Projecting signs may be read horizontally or vertically and may extend into the front or street side building setback, and the sidewalk provided they are setback 4 ft. from the curb and provide a 9 ft. clearance over the sidewalk.
v. Marquee signs shall not exceed 75 percent of the width of the marquee. They are allowed to be placed fully or partially above or below the edge of the marquee (see Figure 68), provided the sign consists of individual letters (as opposed to a panel). Marquee signs are also allowed to hang from the bottom of the marquee facing the street.
vi. Awning signs may extend up to 75 percent of the width of the awning but shall not cover more than 30% of the surface of the awning facing the street.
vii. Awning signs are only allowed on the vertical portion of the awning. They are not allowed on the sloping or curved section.
viii. Hanging signs shall not count toward the maximum sign area allowed, provided they are placed under the awning or marquee, perpendicular to the building, and near the front door of the business. Such signs shall have an 8-foot minimum vertical clearance as measured from grade to the bottom of the sign, and a maximum height of 2 feet.
ix. Roof signs are only allowed west of Orange Avenue and on buildings on the east side of Orange Avenue provided the signs face west.
x. Roof signs shall not exceed fifteen (15) feet in height, or one-third (⅓) of the building height, whichever is less.
xi. 3D signs are permitted. For maximum sign area calculations, the area of the largest face of the smallest cube or rectangular prism which could enclose the entire sign volume shall not exceed the maximum sign area permitted by Ch. 64, Table 1.
(3) Building Sign Illumination.
i. Signs may have interior or exterior illumination sources. Signs with interior illumination are limited to individual letters or push-through lettering. There shall be no illuminated signs facing a single-family home. Existing cabinet signs that change messages shall have opaque backgrounds.
c. Freestanding Sign Standards in all districts except T3.5 General: Freestanding signs must meet the requirements of Ch.64 Table 1C except for the following:
(1) Pole Signs are permitted only on building sites adjacent to Interstate 4 or the 408 Freeway. Only 1 pole sign facing the limited access roadway is permitted per building site. The pole sign copy area must be contained within one (1) plane or geometric shape.
(2) Street-Wall Signs are permitted as follows:
i. Street wall signs shall be placed flat on the street wall facing the street.
ii. The sign shall not exceed a maximum of 36 square feet.
iii. The sign shall not exceed a height of 6 feet measured from the ground.
q) Street Designations and Standards.
1) Corner clips at intersection of Orange Avenue and Michigan Street. A 25-foot corner clip shall be provided at all four corners of the Orange Avenue/Michigan Street intersection, to provide additional pedestrian space and to encourage opportunities for focal entrance features to the City and the district. An easement shall be dedicated to the City to accommodate the entrance feature.
2) Street Classifications: Streets within the SODO special plan shall be classified as either "Primary Streets" or "Secondary Streets" as outlined in Figure 9
a. Streets in the SODO district must be designed with the primary goal of assuring pedestrian comfort and safety and increasing mobility options.
b. All streets must be public. Private, gated, dead-end streets and culs-de-sac are prohibited. Drives within developments designed to function as streets do not have to be dedicated as such.
3) The design of each street must adhere to the specifications and cross-section illustrations for each street type provided in the SODO Complete Streets Master Plan.
Figure 9—SODO Street Designations
[image omitted; see the official code]
r) Specific Use Standards: The following standards are provided for those specific uses detailed below to accommodate these automobile intensive uses while working to preserve and enhance the pedestrian focus of the special plan area.
1) Auto Repair, Carwash: All principal and accessory structures used for automobile service shall be located and constructed in accordance with the following requirements:
a. Bay openings shall be located to the side or rear of the building (see Figure 5) and shall be screened from the street by a street wall meeting the standards of Section L.3.
b. If located on a corner lot, bay openings may face the side-street but must be architecturally integrated into the building design.
c. All bay openings shall be oriented away from adjacent single family residential districts.
d. Accessory car wash structures shall not exceed 20 feet in height.
2) Drive-through Facilities: Drive-through facilities are auto-oriented and therefore discouraged from locating within the SODO district. However, one drive-through lane per use may be allowed through the Conditional Use Permit process and subject to the following standards:
a. Drive-through facilities shall not directly access a Primary Street, as defined in this document and depicted in Figure 9.
b. The number of access points to public streets shall be minimized. This may be accomplished through the provision of joint driveway access from the adjacent sites.
c. Drive-through lanes and windows shall be located along the side or rear of buildings, away from street frontages.
d. Adequate queuing space shall be provided for drive-through windows and order stations in compliance with the City code.
e. A street wall meeting the standards of Section L.3 shall be provided to screen vehicular use areas.
f. Drive through facilities integrated into structured parking may be approved by the DRC instead of CUP provided all other standards for drive-through facilities are met.
3) Automotive Services: Automotive services are auto-oriented uses and may be permitted as shown in Figure 2 of the LDC or Table 1 (Alternative Uses). However, all automotive services shall meet the standards of this document and the following provisions:
a. The convenience store or building shall be located in the front of the site meeting the required building setback of the transect zone. The pumps may be located to the side or rear of the main building.
b. A street wall meeting the standards of Section L.3 shall be provided to screen vehicular use areas.
c. Auto repair bay and car wash openings, service and storage areas, and refuse enclosures shall be oriented away from public view.
d. Gas station canopy clearance shall not exceed eighteen (18) feet.
e. Gas station canopy roofs may not be flat and should incorporate some of the architectural features used in the main building, such as decorative columns, roofing forms and materials.
s) Traditional City Design Standards. The properties north of Michigan Street in the Special Plan area are located within the Traditional City zoning overlay district, and all requirements of the Traditional City zoning overlay district shall continue to apply except as explicitly modified by this Special Plan. Additionally, the desirable design characteristics of the Traditional City shall be extended south of Michigan Street as a part of the design requirements of the SODO Special Plan.
1) The following Traditional City design standards shall apply to properties located south of Michigan Street and north of Illiana Street, and along Pineloch Avenue, within the Special Plan area:
a. Drive-throughs may not be located between the building and a public street.
b. The standards for architectural appearance review contained in Chapter 62 of this Code will guide review of development.
t) Appearance Review Required. Appearance Review shall be required for all new development, substantial improvement, substantial expansion, or change of use within the boundaries of the SODO Special Plan Overlay District depicted in Figure 1.
1) Forms of Appearance Review: The required appearance review may occur in conjunction with a case going to the DRC, other City planning board, or as part of a planning or zoning official determination. Those properties located within the Downtown Community Redevelopment Area (CRA), are required to receive a Certificate of Appearance Approval according to the processes detailed in LDC CH. 65, part 4F.
2) Standards for Appearance Review. The following factors and characteristics relating to a development, and which affect appearance, shall govern the Appearance Review Official's evaluation of a design submission within the SODO Special Plan area:
a. Articulation. The building materials and mass shall be substantially varied, as specified by the transect designation, to break down the overall scale of the structure and visually define each part precisely and clearly so it stands out from the rest of the structure and creates the appearance of multiple buildings. A combination of techniques should be used, including, but not limited to, the utilization of different materials and architectural treatments, projections and recesses of the plane of the structure, appropriate Transparency patterns, and varied rooflines that correspond with the articulation techniques used on the rest of the building.
b. Adherence to the requirements of the SODO District Development Standards and Design Guidelines.
3) Active Ground Floor Use Areas. Sites should be designed to maximize active space at the ground level adjacent to public streets in all transects. For the purposes of the SODO Special Plan, residential, commercial, office, and civic uses shall be considered active uses. Parking, mechanical equipment areas, and storage, including personal storage facilities, shall not be considered active use areas. Any portion of the building facing a public street that is not occupied by an active use shall be treated architecturally in such a way as to be indistinguishable from the active use portions of the building.
4) Site Development Requirements. Other site development requirements, including but not limited to landscaping, bufferyards, fences and walls, stormwater areas, courtyard design, treatment of elevation changes, and signage will also be reviewed during Appearance Review to ensure that the intent of the Special Plan design standards are met.
(Ord. No. 2010-30, § 1, 8-30-2010, Doc. #1008301101; Ord. No. 2020-58, § 1, 1-11-2021, Doc. #2101111202; Ord. No. 2022-56, § 3, 9-26-2022, Doc. #2209261204; Ord. No. 2024-1, § 2, 1-22-2024, Doc. #2401221203)