For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5.2.19 — Outdoor Lighting

Code of the City of Grand Rapids, Michigan (Supp. No. 70: codified through Ordinance No. 2026-08, enacted April 14, 2026) · Grand Rapids City Code § 5.2.19

Corpus is an independent public-information project, not the official City of Grand Rapids website. Stable reference: corpuslaw.us/code/be4ba122-b64b-4e90-9322-cb889fa01adc

Sec. 5.2.19. - Outdoor Lighting.

A. Purpose. The purpose of this Section is to provide reasonable regulations to direct the location, design, illumination level and use of outdoor lighting to minimize its undesirable effects. Specifically, this Section is intended to promote the public health, safety and general welfare of the City of Grand Rapids by: 1. Maintaining safe night-time driver performance on public streets by minimizing both brightly lit surfaces and lighting glare; 2. Promoting lighting that provides security but protects the privacy of adjacent properties; 3. Allowing lighting that is not unduly intrusive or a nuisance to nearby residents, property occupants, and drivers; and 4. Eliminating intrusive artificial light and lighting that unnecessarily contributes to sky glow and energy consumption. B. Lighting Plan. The following information shall be included for all Director Reviews and Site Plan Reviews. Where neither type of approval is required, any of the following items may be required by the Director prior to lighting installation. 1. A site plan drawn to a scale of no more than one (1) inch to thirty (30) feet showing the buildings, landscaping, parking and service areas, and location and type of all proposed outdoor lighting, including the building lighting. 2. A photometric grid overlaid on the proposed site plan. A photometric plan shall indicate lighting levels at ground level based on no greater than a twenty-five (25) foot on-center grid and shall project twenty-five (25) feet onto adjacent properties or to the setback limit line, whichever is greater. Illumination levels shall also be measured for all surrounding streets at the public right-of-way. 3. An analysis showing that the proposed installation conforms to the lighting level standards in this Chapter. All lighting shall have the intensities and uniformity ratio consistent with the Lighting Handbook of the Illuminations Engineering Society of North America (IESNA). 4. Specifications for all proposed lighting fixtures including mounting heights, photometric data, designation as sharp cut-off fixtures by IESNA, Color Rendering Index (CRI) of all lamps (bulbs), and other descriptive information on the fixtures. C. Outdoor Lighting. 1. Type. All outdoor lighting, including freestanding, canopy, pole, and building mounted, shall be fully shielded and directed downward to prevent off-site glare and illumination. No portion of the lamp, reflector, lens, or refracting system may extend beyond the housing or shield, with the exception of pedestrian lighting. 2. Intensity - General. The intensity of light within a site shall not exceed ten (10) footcandles within any part of the site and one (1) footcandle at any lot line, except where it abuts or faces a Residential Zone District or residential use, a maximum of 0.5 footcandles is permitted. 3. Intensity - Vehicle Fuel or Outdoor Sales Areas. a. In areas where lighting levels from existing, similar vehicle fuel stations or outdoor vehicle sales areas or other illuminated areas are on both sides of the lot and across the street, up to eighty (80) percent of the existing light levels may be used. b. For vehicle fuel station canopies and outdoor vehicle sales areas that do not meet the location requirement in Subsection C.3.a. above, an Administrative Departure may be granted for a maximum of twenty (20) footcandles within the site, provided the requirements of Subsection C.2. above apply at the lot line. 4. Uniformity Ratios. To maintain uniformity in light levels across a development and prevent or minimize dark areas, the ratio of maximum to minimum lighting levels on a given lot is measured in footcandles at ground level, and shall not exceed a ratio of fifteen-to-one (15:1). Parking lots shall maintain the same uniformity ratios as the main building or principal use served. 5. Height. Height shall be measured from the ground to the top of the light fixture. Except as otherwise required, the height of fixtures in a Residential Zone District or within two hundred (200) feet of that district shall not exceed the following light source to ground level height limits, except as may be permitted by the Planning Commission. a. Twenty-two and one-half (22½) feet for parking lots. b. Twenty (20) feet for sidewalks and pathways. 6. Fixtures. a. All outdoor fixtures, including building mounted fixtures, shall be full cut-off, shielded fixtures as defined by IESNA. b. Poles for lighting fixtures shall be of a fixed height. Adjustable poles are prohibited. c. High Intensity Discharge (HID) fixtures shall be used in an effort to maintain a unified lighting standard throughout the city and prevent "sky glow." High pressure sodium fixtures shall be prohibited. d. The Director may approve decorative light fixtures as an alternative to shielded fixtures when it can be demonstrated that there shall be no off-site glare or illumination and the proposed fixtures will improve the appearance of the site. 7. Light Poles. The base of light poles in parking areas shall be either flush with grade or mounted on a concrete foundation projecting no more than thirty-six (36) inches above grade. The base of light poles in non-parking areas shall be either flush with grade or mounted on a concrete foundation projecting no more than six (6) inches above grade. [image omitted; see the official code] 5.2.19.C Outdoor Lighting. D. Lighting Reduction. 1. Hours. a. On all non-residentially developed lots which contain a minimum of four (4) parking lot light poles, parking lot lighting levels for ground surface parking lots and the top levels of parking decks or structures must be reduced by at least fifty (50) percent of full operational levels within thirty (30) minutes after the close of business. b. Lighting levels may be reduced by turning off fifty (50) percent of the parking lot lights or by dimming parking lot lighting levels to no more than fifty (50) percent of the levels used during business or activity hours within thirty (30) minutes of the close of business, or by some combination thereof. 2. Security. a. Given that a certain minimum lighting level is recommended for safety and security purposes, this provision does not require parking lot lighting levels to be reduced to less than 0.2 footcandles as measured horizontally at the surface on which the light pole is mounted. b. The need for security lighting (e.g. the lighting for safety of persons and property) shall be demonstrated. To the extent that an area is illuminated for other purposes, independent security lighting is not allowed. c. All security fixtures shall be shielded and aimed so that illumination is directed only to designated areas. In no case shall lighting be directed above a horizontal plane through the top of the lighting fixture, and the fixture shall include full cut-off shields that prevent the light source or lens from being visible on adjacent lots and streets. The use of general floodlighting fixtures is not allowed. E. Architectural Lighting. When buildings and structures are to be illuminated, the Director shall approve a design for the illumination using the following requirements. 1. Direction of Lights. Lighting fixtures shall be carefully sited, aimed and shielded so that light is directed only onto the building façade. Lighting fixtures shall not be directed toward adjacent streets, streets or properties, and light shall not trespass onto surrounding properties. 2. Façade Lighting. Lighting fixtures mounted on the building and designed to wash the façade with light are permitted. Ground or pole-mounted floodlights are not permitted for façade lighting. 3. Accent Lighting. Luminous tube (neon), string lighting, LED or fluorescent lighting may be allowed as an architectural detail on the exterior of any structure, provided that such lighting shall not completely outline or define property lines, sales areas, roofs, doors, windows or similar areas in a manner that is not primarily for safety purposes. Accent lighting may be approved by a Director Review upon determining that the accents would not cause off-site glare or light pollution and that lighting is not intended to be used as the equivalent of a sign. Notwithstanding, seasonal lighting displays, including string lighting, may be allowed without Director Review in conjunction with a nationally recognized holiday provided such displays are strung no sooner than sixty (60) days before the holiday and shall be removed within twenty (20) days following the holiday. 4. Landscape Lighting. The illumination of landscaping shall not generate excessive light levels, cause glare, or direct light beyond the landscaping. F. Temporary Light Display in TN-CC Zone District. 1. Temporary light displays are permitted in connection with planned events at the following uses only. a. An arena with a seating capacity of ten thousand (10,000) persons or more; and b. A convention center having one hundred thousand (100,000) square feet or more of floor area. 2. These displays shall only be permitted on the premises in which the event is held. 3. For each qualifying use, these displays shall be permitted for up to ten (10) events each year and may be displayed for a maximum of eight (8) days for each event. The location, number, size and general character of these displays shall be approved by the Director. 4. Sign Permit. A sign permit is required for all temporary light displays allowed in this Section. G. Other Lighting Requirements. 1. Indirect illumination of signs, canopies, bollards and buildings is permitted provided a maximum one hundred twenty-five (125) watt bulb is used and placed or shielded to prevent glare. 2. Electrical feeds to lighting standards shall only run underground. 3. The use of a laser light source, search lights or any similar high intensity light for outdoor advertisement or entertainment is prohibited, except as permitted in the TN-CC Zone District under Section 5.2.19.F. 4. Lighting shall not consist of or have the appearance of movement or flashing components, except as otherwise permitted in this Chapter. H. Public Street Lighting. The cost of installing and operating approved street lighting on any public street shall be through a financial method approved by the City or by the Michigan Department of Transportation. The costs of all other lighting systems shall be borne by the developer/property owner. I. Exemptions. The following outdoor light fixtures are exempt from the provisions of this Section. 1. Outdoor light fixtures installed prior to the effective date of this Chapter. Fixture replacements shall comply with the requirements of this Section in accordance with the provisions of Section 5.3.06.C. to the extent that the overall appearance of the site is not adversely affected. The Director may require that existing light fixtures be redirected in conditions where excessive glare onto adjacent properties and roadways creates a nuisance or safety concern. 2. Streetlights within a public right-of-way. 3. Pedestrian walkway ground lighting. 4. Outdoor light fixtures which use an incandescent light bulb of one hundred fifty (150) watts or less, except where they create a hazard or nuisance from glare or spillover light. 5. Lighting necessary for street or utility construction or emergencies. 6. Lighting necessary for designated recreational fields or similar uses that cannot reasonably comply with the standards and provide sufficient illumination of the recreational field for safe use, following IESNA standards. The fixtures shall be aimed so that their beams are directed and fall within the primary playing or performance area. Lights shall be turned off within one-half (½) hour of the completion of the event. 7. Government facilities, parks and open areas, public utility facilities, and other uses where sensitive or dangerous materials are located may submit a Site Security Plan to the Director requesting deviations from the requirements of this Section. The Plan may be approved, or approved with conditions, upon finding that: a. The lighting is necessary for adequate protection of the public; b. The condition, location, or use of the land, or history of activity in the area, indicates the land or any materials stored or used on it are in greater danger of theft or damage, or members of the public are at greater risk for harm than on other property; and c. The deviations do not have a significant adverse effect on neighboring areas. J. Administrative Departure. An Administrative Departure from the requirements this Section may be granted if it is determined that proposed lighting otherwise meets the purposes of this Section and does not adversely affect the health, safety and welfare of the public.

Ask a question about Grand Rapids law

Corpus searches the Grand Rapids sections it holds and shows the ones that match, with their citations. Free, no sign-in.