§ 31-113 — IECC Amendments - Chapter 4 (Commercial)

Scottsdale Revised Code (Supp. No. 80: codified through Ordinance No. 4681, adopted July 1, 2025) · Scottsdale Revised Code § 31-113

Corpus is an independent public-information project, not the official City of Scottsdale website. Stable reference: corpuslaw.us/code/be6b80ca-6d06-413c-9653-b4115c2afbf0

Sec. 31-113. - IECC Amendments - Chapter 4 (Commercial).

Only the following portions of CHAPTER 4, COMMERCIAL ENERGY EFFICIENCY, are amended: (a) Section C402.3, Roof solar reflectance and thermal emittance, is amended to read as follows, with the exceptions and table remaining unchanged. C402.3 Roof solar reflectance and thermal emittance. Low-sloped roof surfaces over conditioned and unconditioned spaces in Climate Zones 0 through 3 shall comply with one or more of the options in Table C402.3. (b) Section C405.12, Energy Monitoring, is deleted in its entirety. (c) A new Section C405.13, Electric Vehicle (EV) charging infrastructure, is added as follows: C405.13 Electric Vehicle (EV) charging infrastructure. New construction shall accommodate future installation and use of Electric Vehicle Supply Equipment (EVSE) in accordance with the National Electrical Code (NFPA 70). C405.13.1 Required EV installed spaces and EV capable spaces. Parking shall be provided with EV installed spaces and EV capable spaces in accordance with Table C405.13.1. The required number of EV installed spaces orEV capable spaces shall be rounded up to the next highest whole number. Where a branch circuit serves a single charging space, it shall have a capacity not less than of 8.3 kVA (40A, 208/240V). Where a branch circuit serves multiple charging spaces, anAutomatic Load Management System (ALMS) may be used to reduce the total electrical capacity provided that all charging spaces are capable of simultaneously charging at a minimum rate of 4.1 kVA (20A, 208/240V). For EV capable spaces, the electrical service panel shall have reserved circuit breaker space(s) labeled "Future EV Charging". Raceway(s) shall be installed from the electrical service panel to outlet box(es) within the planned EV charging parking area(s). Outlet box(es) shall be labeled "Future EV charging". TABLE C405.13.1 ELECTRIC VEHICLE CHARGING INFRASTRUCTURE REQUIREMENTS Occupancy Group | Minimum number of EV Installed Spacesa | Minimum number of EV Capable Spacesa Group R-1 (hotels, motels) and Group R-2 (apartments, condominiums) | 4% of total required parking spaces | 20% of total required parking spaces a Parking spaces designated for other than passenger vehicles may be excluded from the number of parking spaces used to calculate the minimum number of EV spaces. C405.13.2 Documentation. Construction documents shall indicate location(s) for EV installed spaces and EV capable spaces. Information shall be provided on raceway methods, wiring schematics and electrical load calculations to verify the electrical panel service capacity, including any on-site distribution transformers, to ensure sufficient capacity to simultaneously charge all required EV spaces at the rated amperage of the EVSE. (d) Table C406.10.2, Energy Use Categories, is revised by adding the following: TABLE C406.10.2 ENERGY USE CATEGORIES LOAD CATEGORY | DESCRIPTION OF ENERGY USE Electric vehicle charging | Energy used for electric vehicle charging (e) Table C407.2, Requirements for Total Building Performance, is revised by adding the following: TABLE C407.2 REQUIREMENTS FOR TOTAL BUILDING PERFORMANCE Envelope C402.3 | Roof solar reflectance and thermal emittance (f) Exceptions to Section C408.2 Mechanical systems and service water-heating systems commissioning and completion requirements, are amended to read as follows: Exceptions: The following systems are exempt: 1. Mechanical systems in buildings where the total mechanical equipment capacity is less than 180,000 Btu/h (52.8 kW or 15 tons) for cooling, 300,000 Btu/h (87.9 kW) for space-heating and 10,000 cfm for ventilation. 2. Service water-heating systems rated under 50,000 Btu/h (14.7 kW). 3. Water pumping and mixing systems under 5 hp (4kW). 4. Systems included in Section C403.5 that serve individual dwelling units and sleeping units.

(Ord. No. 4575, § 1(Res. No. 12503, § 1(Exh. A)), 12-6-22)

Ask a question about Scottsdale law

Corpus searches the Scottsdale sections it holds and shows the ones that match, with their citations. Free, no sign-in.