§ 24.09.340 — Section R602.10.8.1
San José Municipal Code (Supp. No. 5: codified through Ordinance No. 31341, enacted August 25, 2026) · San José Municipal Code § 24.09.340
Corpus is an independent public-information project, not the official City of San Jose website. Stable reference: corpuslaw.us/code/be9db755-7883-44b9-81cf-f635f09937e4
24.09.340 - Section R602.10.8.1.
CRC Section R602.10.8.1 is amended to read as follows: 602.10.8.1 Braced wall panel connections for Seismic Design Categories D0, D1, and D2. Braced wall panels shall be fastened to required foundations in accordance with Section R602.11.1, and top plate lap splices shall be face-nailed with not less than eight 16d nails on each side of the splice. Wall sheathing shall not be attached to framing members by adhesives. All braced wall panels shall extend to the roof sheathing and shall be attached to parallel roof rafters or blocking above with framing clips (eighteen-gauge minimum) spaced at maximum twenty-four inches (6,096 mm) on center with four 8d nails per leg (total eight 8d nails per clip). Braced wall panels shall be laterally braced at each top corner and at maximum twenty-four-inch (6,096 mm) intervals along the top plate of discontinuous vertical framing.
(30326.)
Ask a question about San Jose law
Corpus searches the San Jose sections it holds and shows the ones that match, with their citations. Free, no sign-in.