Sec. 49-1727. - Slope of building sewer.
The building sewer shall be laid with a uniform slope from the public sewer to the end of the building drain. No building sewer shall be laid with less than one-eighth inch per foot fall (or one percent grade) or as prescribed in section 49-903, Note 4. If allowed under section 49-903, Note 4, the following procedures will be used: (a) Sewer pipe, regardless of size, shall be installed in a bed of Class IB material and laid with the aid of a laser. (b) The pipe must be flushed with water and then videoed in the presence of a plumbing inspector after backfill is completed.
(Ord. No. 40524, § 1, 10-20-15)