Sec. 68.174. - Standards for conditional uses in the FF Flood Fringe District.

(a) Alternative elevation methods other than the use of fill may be utilized to elevate a structure's lowest floor above the regulatory flood protection elevation. These alternative methods may include the use of stilts, pilings, parallel walls or above grade, enclosed areas such as crawl spaces or tuck-under garages. The base or floor of an enclosed area shall be considered above grade and not a structure's basement or lowest floor if: 1) the enclosed area is above grade on at least one (1) side of the structure; 2) is designed to internally flood and is constructed with flood-resistant materials; and 3) is used solely for parking of vehicles, building access or storage. The above-noted alternative elevation methods are subject to the following additional standards: (1) Design and certification. The structure's design and as-built condition must be certified by a registered professional engineer or architect as being in compliance with the general design standards of the Minnesota State Building Code and, specifically, that all electrical, heating, ventilation, plumbing and air conditioning equipment and other service facilities must be at or above the regulatory flood protection elevation or be designed to prevent floodwater from entering or accumulating within these components during times of flooding. (2) Specific standards for above grade, enclosed areas. Above grade, fully enclosed areas such as crawl spaces or tuck-under garages must be designed to internally flood and the design plans must stipulate: a. A minimum area of "automatic" openings in the walls where internal flooding is to be used as a floodproofing technique. There shall be a minimum of two (2) openings on at least two (2) sides of the structure and the bottom of all openings shall be no higher than one (1) foot above grade. The automatic openings shall have a minimum net area of not less than one (1) square inch for every square foot of enclosed area subject to flooding unless a registered professional engineer or architect certifies that a smaller net area would suffice. The automatic openings may be equipped with screens, louvers, valves or other coverings or devices, provided that they permit the automatic entry and exit of floodwaters without any form of intervention. b. That the enclosed area will be designed of flood-resistant materials in accordance with the FP-3 or FP-4 classifications in the Minnesota State Building Code and shall be used solely for building access, parking of vehicles or storage. (b) Basements, as defined in section 68.114, shall be subject to the following: (1) Residential basement construction shall not be allowed below the regulatory flood protection elevation except as authorized in subsection (e) of this section. (2) Nonresidential basements may be allowed below the regulatory flood-protection elevation, provided the basement is protected in accordance with subsection (c) or (e) of this section. (c) All areas of nonresidential structures including basements to be placed below the regulatory flood protection elevation shall be structurally dry floodproofed in accordance with the FP-1 or FP-2 floodproofing classifications in the Minnesota State Building Code. This shall require making the structure watertight, with the walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effects of buoyancy. Structures floodproofed to the FP-3 or FP-4 classification shall not be permitted. (d) The storage or processing of materials that are, in times of flooding, flammable, explosive or potentially injurious to human, animal or plant life is prohibited. Storage of other materials or equipment may be allowed if readily removable from the area within the time available after a flood warning and in accordance with a plan approved by the planning commission, or if elevated above the regulatory flood protection elevation by alternative methods which meet the requirements of subsection (a) above. Storage of bulk materials may be allowed provided an erosion/sedimentation control plan is submitted which clearly specifies methods to be used to stabilize the materials on site for a regional flood event. The plan must be prepared and certified by a registered professional engineer or other qualified individual acceptable to the planning commission. (e) When the Federal Emergency Management Agency has issued a letter of map revision-fill (LOMR-F) for vacant parcels of land elevated by fill to the one (1) percent chance flood elevation, the area elevated by fill remains subject to the provisions of this chapter. A structure may be placed on the area elevated by fill with the lowest floor below the regulatory flood protection elevation provided the structure meets the following provisions: (1) No floor level or portion of a structure that is below the regulatory flood protection elevation shall be used as habitable space or for storage of any property, materials, or equipment that might constitute a safety hazard when contacted by floodwaters. Habitable space shall be defined as any space in a structure used for living, sleeping, eating or cooking. Bathrooms, toilet compartments, closets, halls, storage rooms, laundry or utility space, and similar areas are not considered habitable space. (2) For residential and nonresidential structures, the basement floor may be placed below the regulatory flood protection elevation subject to the following standards: a. The top of the immediate floor above any basement area shall be placed at or above the regulatory flood protection elevation. b. Any area of the structure placed below the regulatory flood protection elevation shall meet the "reasonably safe from flooding" standards in the Federal Emergency Management Agency (FEMA) publication entitled "Ensuring that Structures Built on Fill In or Near Special Flood Hazard Areas Are Reasonably Safe From Flooding," Technical Bulletin 10-01, a copy of which is hereby adopted by reference and made part of this chapter. In accordance with the provisions of this chapter, and specifically section 68.133(g), the applicant shall submit documentation that the structure is designed and built in accordance with either the "Simplified Approach" or "Engineered Basement Option" found in FEMA Technical Bulletin 10-01. c. If the ground surrounding the lowest adjacent grade to the structure is not at or above the regulatory flood protection elevation, then any portion of the structure that is below the regulatory flood protection elevation must be floodproofed consistent with any of the FP-1 through FP-4 floodproofing classifications found in the Minnesota State Building Code.

(Ord. No. 25-72, § 1, 12-10-25)

Ask a question about St. Paul law

Corpus searches the St. Paul sections it holds and shows the ones that match, with their citations. Free, no sign-in.