22.602.045 - Fees
A. The fees for the following non-hazardous material permits are established in Schedule A. See Table A for 22.602.045.
Non-Hazardous Materials Permit Fees
Effective January 1, 2025
Schedule A Table A for 22.602.045 See footnotes Time Chargea, Late Feebapplicable to all Schedule A permit fees.
Code No. | Permit Title | Original Fee | Renewal Fee
2501 | Place of Assembly, non-profit | No fee | No fee
2501.1 | Place of Assembly, non-profit, Occupant Load 100—999 and no stage | No fee | No fee
2501.2 | Place of Assembly, non-profit, Occupant Load 1,000 or greater, or any Occupant Load with a stage | No fee | No fee
2502.1 | Place of Assembly, Occupant Load 100—199 | $571 | $571
2502.2 | Place of Assembly, Occupant Load 200—999 | $715 | $715
2504.1 | Place of Assembly, Occupant Load 1,000—2,999 | $854 | $854
2504.2 | Place of Assembly, Occupant Load 3,000—9,999 | $1,456 | $1,456
2504.3 | Place of Assembly, Occupant Load 10,000—19,999 | $2,500 | $2,500
2504.4 | Place of Assembly, Occupant Load 20,000 and over | $3,327 | $3,327
2504.5 | Covered and Open Mall Buildings, annual, includes vehicle display | $488 | $488
2509 | Open flame, Place of Assembly, Occupant load 50—99 | $252 | $252
2510 | Open flame (non-profit), Place of assembly, Occupant load 50—99 | No fee | No fee
a Time Charge. Where a time charge is indicated, a fee shall be charged equal to actual labor costs plus administrative overhead costs for field inspection and/or review exceeding one hour. When requested or when necessary for Fire Prevention Division staff to conduct inspections for the purpose of Seattle Fire Code compliance for any of the above Schedule A permits outside of regular business hours (Monday through Friday, 8 a.m. to 4:30 p.m.), a time charge will be added to the above permit cost. The time charge, when applicable, will be equal to the actual labor cost, including administrative overhead costs and other services.
b Late Fee. Payment for Schedule A permit renewals, where allowed, which is received more than 30 calendar days but fewer than 91 calendar days past the permit expiration date shall be equal to 1.25 times the renewal fee. The renewal permit will be valid for only one year from the expiration date of the prior permit. Permits for which no renewal payment has been received within 90 calendar days following the permit expiration date will be cancelled. Permits that have been cancelled may be reinstated, effective from the expiration date, if the permit holder pays a late penalty of 1.5 times the fee for an original permit within 180 days of the expiration date. Thereafter, any person whose permit has been cancelled shall not be allowed to reinstate the cancelled permit, but shall be required to submit a new permit application and pay a late penalty of 1.5 times the fee for an original permit.
B. The fees for the following special event permits are established in Schedule B. See Table B for 22.602.045.
Special Events Permit Fees
Effective January 1, 2025
Schedule B Table B for 22.602.045 Special Event Permits See notes Late Feea,b, Fireworkscapplicable to all Schedule B permit fees.
Code No. | Permit Title | Original Fee | Renewal Fee
107 SE | Ceremonial fireworks - Special Events | No fee | No renewal
1102-FE | Flame effects, temporary, single event (non-LPG) b | $273 | No renewal
1102-H | Open flame/flame effects, temporary, single event (non-LPG) a | $273 | No renewal
2500-FM | Place of Assembly, temporary, farmers' market program where the event alters the existing exit configuration and/or fire lanes a | No fee | No renewal
2500-LPG | Farmers' Market, LPG, portable outdoor heating, annual, when issued with a Place of Assembly Permit Code 2500-FM a | $408 | $408
2503 | Place of Assembly, temporary Indoor with less than 1,000 people, where the event alters the existing exit configuration and/or fire lanes b | $329 | No renewal
2503.2 | Temporary Outdoor Assembly Event, with projected attendance of 500—999, or that confines 100—999 attendees by permanent or temporary barricades or fencing b | $329 | No renewal
2505.1 | Place of Assembly, or tradeshow/exhibit/carnival/fair, temporary Indoor or Outdoor Assembly Event, attendance 1,000—2,999 where the event alters the existing exit configuration and/or fire lanes b | $542 | No renewal
2505.2 | Place of Assembly, or tradeshow/exhibit/carnival/fair, temporary Indoor or Outdoor Assembly Event, attendance 3,000—9,999 where the event alters the existing exit configuration and/or fire lanes b | $1,081 | No renewal
2505.3 | Place of Assembly, or tradeshow/exhibit/carnival/fair, temporary Indoor or Outdoor Assembly Event, attendance 10,000—19,999 where the event alters the existing exit configuration and/or fire lanes b | $1,544 | No renewal
2505.4 | Place of Assembly, or tradeshow/exhibit/carnival/fair, temporary Indoor or Outdoor Assembly Event, attendance 20,000 and over where the event alters the existing exit configuration and/or fire lanes b | $3,090 | No renewal
2511 | Open flame/flame effects, Place of Assembly, valid 12 months a | $719 | No renewal
3201 | Tent or air-supported structure, for use when no assembly permit is required b | $362 | No renewal
3201-CTY | Tent or air-supported structure, for use with City of Seattle Special Events Permit b | $362 | No renewal
3201-SFD | Tent or air-supported structure, for use with valid Seattle Fire Department Special Events Permit b | No charge | No renewal
7801.1 | Fireworks use/display outdoor b, c | $1,805 | No renewal
7801.3 | Fireworks barge load/unload only b, c | $902 | No renewal
7802 | Fireworks use/display before a proximate audience b, c | $957 | No renewal
8020 | Flammable Liquids, Place of Assembly, temporary single event a | $362 | No renewal
8205.1 | Flame effects (all fuel types), special events, temporary single event, projected attendance 250-999 b | $580 | No renewal
8205.2 | Flame effects (all fuel types), special events, temporary single event, projected attendance 1,000 and above b | $1,740 | No renewal
8205.3 | Flame effects (all fuel types), special events, temporary single event, projected attendance 250 and above, issued in conjunction with an SFD 7801.1 or 7802 Permit for Pyrotechnics b | $580 | No renewal
8206 | LPG/flame effects, special events, temporary, valid 12 months a | $408 | No renewal
8206-FVH | LPG (propane) or open flame, special events, temporary, valid 12 months, for food booth or heating a (Not intended for mobile food preparation vehicles) | $408 | $408
8206-TRK | Mobile food preparation vehicle including LPG (propane), CNG (compressed natural gas), and/or solid fuel/open flame/charcoal, with SFD inspection, annual a (May be renewed as 8206-TRK or 8206-RGL) | $490 | $490
8206-RGL | Mobile food preparation vehicle including LPG (propane), CNG (compressed natural gas), and/or solid fuel/open flame/charcoal used for food vending or heating, with regional inspection, annual a (May be renewed as 8206-TRK or 8206-RGL) | $408 | $408
8207-FE | LPG for flame effects, temporary, single event b | $273 | No renewal
8207-VH | LPG/Solid Fuel for cooking/heating, single event a | $273 | No renewal
8208 | Special hazards, including indoor vehicle display, Place of Assembly, temporary single event (not required for holders of a 2504.5 permit) a | $273 | No renewal
a Late Fee Applied. Schedule B permit applications for permits 1102-H, 2500 FM, 2511, 8020, 8206, 8207-VH, and 8208 that are received by the Seattle Fire Department fewer than ten calendar days prior to the event, not counting the day of the event for which they apply, shall be assessed a late fee in addition to the permit fee. The late fee shall be equal to 50 percent of the original permit fee. Applications received three or fewer business days prior to the event may not be processed and the permit may not be issued. Payment for Schedule B permit renewals, where allowed, which is received more than 30 calendar days but fewer than 91 calendar days past the permit expiration date shall be equal to 1.25 times the renewal fee. The renewal permit will be valid for only one year from the expiration date of the prior permit. Permits for which no renewal payment has been received within 90 calendar days following the permit expiration date will be cancelled. Permits that have been cancelled may be reinstated, effective from the expiration date, if the permit holder pays a late penalty of 1.5 times the fee for an original permit within 180 days of the expiration date. Thereafter, any person whose permit has been cancelled shall not be allowed to reinstate the cancelled permit, but shall be required to submit a new permit application and pay a late penalty of 1.5 times the fee for an original permit. Note: new applications for permits 8206 (all types) and 2500-LPG are not subject to late fees; the renewal process for these annual permits does include late fees and if permits are not renewed timely, late fees related to the renewal will be applied as described above in this footnote a.
b Late Fee Applied. Applications for temporary, non-renewable Schedule B permits 1102-FE, 2503 to 2505.4, 3201, 3201-CTY, 3201-SFD, 7801.1 to 7802, 8205.1 to 8205.3, and 8207-FE that are received by the Seattle Fire Department fewer than 30 calendar days prior to the event, not counting the day of the event for which they apply, shall be assessed a late fee in addition to the permit fee and any applicable time charge. The late fee shall be equal to 50 percent of the original permit fee. Applications received three or fewer business days prior to the event may not be processed and the permit may not be issued.
c Fireworks Permits. An application for a fireworks permit shall be made in writing to the fire code official at least 30 calendar days in advance of the display. At the time the permit application is submitted, the fire code official shall be consulted regarding requirements for standby fire apparatus.
C. The fees for the following special hazards permits are established in Schedule C. See Table C for 22.602.045.
Special Hazards Permits
Fees for special hazards permits are established in Schedule C (See Table C for 22.602.045). In some cases these fees are based on the quantity of hazardous material stored and/or handled at the site and the relative risk posed by each material.
1. Definitions:
a. "Quantity Range Number," as established in the Quantity Range Table below, is a number between 1 and 2 that is assigned to a hazard category based upon the amount of hazardous material located at the site.
QUANTITY RANGE TABLE
QUANTITY RANGE NUMBER | SOLIDS (Pounds) | LIQUIDS (Gallons) | GASES (Cubic Feet)
1 | 0—550 | 0—55 | 0—1,000
1.25 | >550—5,500 | >55—550 | >1,000—5,000
1.5 | >5,500—27,500 | >550—2,750 | >5,000—50,000
1.75 | >27,500—55,000 | >2,750—5,500 | >50,000—100,000
2 | >55,000 | >5,500 | >100,000
b. "Assigned Risk Factor," as established below, is a number between 1 and 1.5 assigned to each hazard class and category of hazardous material indicating the relative hazard posed by materials in that hazard category and the potential nature of controls required by the Fire Code.
Hazard Class | Assigned Risk Factor | Hazard Class | Assigned Risk Factor
Aerosol products | 1.3 | Organic peroxides
Cellulose nitrate | 1.3 | Unclassified | 1.5
Combustible fiber | 1.2 | Class I | 1.4
Combustible liquids | Class II | 1.3
Class II | 1.2 | Class III | 1.2
Class III-A | 1.1 | Class IV | 1.0
Class III-B | 1.0
Compressed gases | Oxidizers
Highly toxic | 1.5 | Class 4 | 1.5
Pyrophoric | 1.4 | Class 3 | 1.4
Flammable | 1.4 | Class 2 | 1.2
Unstable | 1.4 | Class 1 | 1.1
Oxidizing | 1.4 | Pyrophoric liquids and solids | 1.3
Toxic | 1.3 | Toxic liquids and solids | 1.2
Corrosive | 1.3 | Unstable (reactive) liquids and solids
Corrosive Liquids and Solids | 1.1 | Class 4 | 1.5
Cryogenic Fluids | 1.3 | Class 3 | 1.4
Explosives | 1.5 | Class 2 | 1.3
Fireworks | 1.4 | Class 1 | 1.0
Flammable liquids, Class I | 1.4 | Water-reactive materials
Flammable solids | 1.3 | Class 3 | 1.5
Highly toxic liquids and solids | 1.5 | Class 2 | 1.3
Magnesium | 1.3 | Class 1 | 1.0
c. "Fixed permit cost" is the minimum cost for the Seattle Fire Department to issue a hazardous material permit. The fixed permit cost is $361.
d. "Base permit fee" is determined by multiplying the sum of the products of the quantity range number and assigned risk factor for each hazard class by the fixed permit cost and is represented by the following equation:
Base permit fee = [Σ (Q 1 )(R 1 ) + (Q 2 )(R 2 )…] [F]
Where:
Q = The quantity range number.
R = The assigned risk factor.
F = The fixed permit cost of $361.
When an individual material has multiple hazards, only the hazard presented by the hazard class that has been assigned the highest risk factor shall be considered in the fee calculation.
Example:
XYZ Company stores 50 gallons of gasoline and 200 gallons of 50% nitric acid. Gasoline is classified as a Class I flammable liquid, which has an assigned risk factor of 1.4. Nitric acid (50%) is classified as both a corrosive liquid and a Class 2 oxidizer. Because 50% nitric acid presents two separate hazards (corrosive and Class 2 oxidizer) only the Class 2 oxidizer hazard is considered in the fee calculation because it has an assigned risk factor of 1.2 compared to the 1.1 risk factor assigned to corrosives.
Base permit fee = [(1)(1.4) flammable + (1.25)(1.2) Class 2 oxidizer ] [$361]
Base permit fee = $1,046.90
Special Hazards Permit Fees
Effective January 1, 2025
Schedule C Table C for 22.602.045 Special hazards permits 1
Code Numbers | Permit Title | Original Fee | Renewal Fee
Miscellaneous Special Hazards Permits
916-Install | Installation of gas detection systems | $554 | No renewal
1070 | Temporary permit for a facility under a compliance plan 2 | Half of annual permit fee 2 | No renewal 2
1071 | Special inspection/permit - temporary | $372 plus time charge | No renewal
1073 | Cruise ship hazardous operations | $361 plus time charge | No renewal
1074 | Temporary storage and use of flammable and combustible liquids (Classes I, II, and III) at construction sites, valid up to 6 months | $506 | No renewal
1101 | Combustible material storage | $281 | $281
1103 | Waste handling | $361 | $361
1104 | Rooftop heliport | $925 | $925
1206-Install | Installation of capacitor energy storage systems | $554 | No renewal
1207-Install | Installation of fuel cell power systems | $554 | No renewal
1506 | Manufacture of reinforced plastics | Fee worksheet | Half original 1
2401 | Aviation facility | $361 | $361
2520 | Tire rebuilding plant | $361 | $361
2521 | Outdoor tire and tire byproduct storage | $361 | $361
2701-T | Hazardous material stabilization, temporary | $361 plus time charge | No renewal
2801 | Combustible fibers | $361 | $361
2902-Minor | Repair garage—minor. See Seattle Fire Code Chapter 2 for definitions. | $494 | $494
2903-Major | Repair garage—major*. See Seattle Fire Code Chapter 2 for definitions. *Spray painting requires a separate permit. | $660 | $660
3001 | Lumber yards and woodworking facilities | $361 | $361
3202 | Lithium battery storage | $361 | $361
3203 | Additive manufacturing (3-D printing) | $361 | $361
3401 | Wrecking yard | $431 | $431
3402-Install | Installation of tanks for storage of combustible liquid serving emergency/standby power systems | $626 | No renewal
4601 | Fruit and crop ripening | $361 | $361
4701 | Fumigation and thermal insecticidal fogging, temporary | $361 | No renewal
4801 | Magnesium working | $361 | $361
5001 | Manufacture of organic coatings | Fee worksheet | Half original 1
5101 | Semiconductor fabrication facilities | Fee worksheet | Half original 1
6201 | Industrial oven | $361 | $361
6401 | Energy storage systems | $361 | $361
6401-Install | Installation of energy storage systems | $407 | May be renewed as 6401
7601 | Combustible dust-producing operation | $361 | $361
7907 | Fuel dispensing (open use) into equipment from aboveground tank | $361 | $361
8101 | High-piled combustible storage | $361 plus time charge | $361 plus time charge
Roofing Operations
7901 | Roofing operations—annual | $361 plus $361 per unit | $361 plus $361 per unit
7901T | Roofing operations—temporary | $361 | No renewal
Dry Cleaning
3603 | Dry cleaner | $361 | $361
Flammable Finishes
2601 | Floor finishing, temporary, > 350 square feet | $361 | No renewal
4501 | Limited spray finishing | $361 | $361
4502 | Spray finishing process (non-marine) (below permit quantities) | $361 | $361
4502-WB | Spray finishing process (non-marine)—Water-based finish | No fee | No fee
4503 | Spray finishing process (non-marine) (above permit quantities) | Fee worksheet | Half original 1
4504 | Marine spray finishing process (below permit quantities) | $361 | $361
4505 | Marine spray finishing process (above permit quantities) | Fee worksheet | Half original 1
4509 | Powder coating, dipping and electrostatic operations | $361 | $361
Motor vehicle/Marine motor vehicle fuel-dispensing facility
2204 | Hydrogen motor vehicle fuel dispensing station | $925 | $925
5201 | Motor vehicle fueling station (underground tank) | $361 | $361
5202 | Motor vehicle fueling station (above ground tank) | $669 | $669
5203 | Marine motor vehicle fueling station | $797 | $797
5204 | Liquefied petroleum gas motor vehicle fuel-dispensing station | $797 | $797
5205 | Compressed natural gas motor vehicle fuel-dispensing station | $797 | $797
Hot Work Operations
4911 | Annual non-marine cutting and welding (1—3 units) | $606 | $606
4912 | Annual non-marine cutting and welding (4 or more units) | $1,014 | $1,014
4913 | Temporary non-marine cutting and welding | $361 | No renewal
4914 | Annual hot work on marine vessels | $1,583 | $1,583
4915 | Temporary marine hot work | See Table C-4915 | No renewal
4901 | Shipyard | $3,184 | $3,184
4902 | Type I designated marine hot work facility (for all vessels regardless of length) | $1,365 | $1,365
4903 | Type II designated marine hot work facility (for vessels < 200 feet) | $792 | $792
LP-gas
8201-Install | Installation of liquid petroleum gas (LPG) in stationary containers, residential and non-residential | $554 | May be renewed as 8202-R or 8202-STO
8202-R | Storage of liquid petroleum gas (LPG) in portable or stationary containers, > 500 gallons, R3 residential occupancies * Permit must be issued within one year of issue of 8201-Install permit. | $554 | $554
8202-STO | Storage of liquid petroleum gas (LPG) in portable or stationary containers, non-residential, all sizes * Permit must be issued within one year of issue of 8201-Install permit. | $554 | $554
8202-EX | LPG cylinder exchange at retail occupancy | $554 | $554
8202-POH | Portable outdoor heater at permanent drinking or dining establishment | $554 | $554
8202-Construction | Temporary storage and use of LPG at construction sites, valid up to 6 months | $554 | No renewal
Hazardous materials
801-A | Combustible liquid storage and use | Fee worksheet | Half original 1
801-B | Corrosive compressed gas | Fee worksheet | Half original 1
801-C | Corrosive liquids and solids | Fee worksheet | Half original 1
801-D | Cryogenic fluids | Fee worksheet | Half original 1
801-E | Explosives | Fee worksheet | Half original 1
801-F | Flammable compressed gas (except LPG) | Fee worksheet | Half original 1
801-G | Flammable liquids | Fee worksheet | Half original 1
801-H | Flammable solids | Fee worksheet | Half original 1
801-I | Highly toxic compressed gas | Fee worksheet | Half original 1
801-J | Highly toxic liquids and solids | Fee worksheet | Half original 1
801-K | Organic peroxides | Fee worksheet | Half original 1
801-L | Oxidizing compressed gas | Fee worksheet | Half original 1
801-M | Oxidizer liquids and solids | Fee worksheet | Half original 1
801-N | Pyrophoric compressed gas | Fee worksheet | Half original 1
801-O | Pyrophoric liquids and solids | Fee worksheet | Half original 1
801-Q | Toxic compressed gas | Fee worksheet | Half original 1
801-R | Toxic liquids and solids | Fee worksheet | Half original 1
801-S | Unstable (reactive) compressed gas | Fee worksheet | Half original 1
801-T | Unstable (reactive) liquids and solids | Fee worksheet | Half original 1
801-U | Water-reactive liquids and solids | Fee worksheet | Half original 1
801-V | Aerosols (Level 2 and 3) | Fee worksheet | Half original 1
801-W | Cellulose nitrate (pyroxylin) plastics | Fee worksheet | Half original 1
6101 | Annual residential heating oil tank decommissioning/removal | No fee | No fee
6103 | Residential heating oil tank decommissioning | $184 | No renewal
7401 | Compressed gas (Inert and simple asphyxiates) | $361 | $361
7402 | Medical gas system | $361 | $361
7403 | Carbon dioxide carbonating equipment used for beverages or cannabis | $361 | $361
7501 | Non-flammable cryogens | $361 | $361
7900 | Flammable/combustible liquid tank vehicle | $361 | $361 3
7900-ODMF | On-demand mobile fueling vehicle | $361 | $361 3
7903 | Gas freeing of tank vessels and barges | $1,583 | $1,583
7904 | Bulk plant or terminal | Fee worksheet | Half original 1
7905 | Master fuel transfer to marine vessels | $361 | $361
7906 | Marine refueling facility (for marine vessels), annual | $361 | $361
7906-T | Marine refueling temporary (for unplanned refueling at a facility without a 7906 permit) | $361 | No renewal
7908 | Commercial flammable or combustible liquid tank decommissioning | $361 | No renewal
7912 | Mobile fleet fueling operator (land-based) | $389 | $389
7912-ODMF | On-demand mobile fueling operator | $389 | $389
7913 | Mobile fleet fueling site | $389 | $389
7913-ODMF | On-demand mobile fueling site | $389 | $389
8001 | Incidental flammable and combustible liquids (≤ 30 gallons) | $361 | $361
8002 | Laboratory per control area | $361 per control area | $361 per control area
8010 | LPG tank vehicle | $361 | $361 3
8025 | Marine Terminal | $5,143 + [$371 × no. of acres >5] | Same as base
8030 | Container Freight Station | $2,216 | $2,216
1 Schedule C fee worksheet-based permits shall be renewed at one-half the permit origination fee or $361, which is the minimum renewal fee, whichever is greater. 2 This temporary permit is valid for six months and is issued to a facility placed under a long-term compliance plan while the facility works towards full compliance with the Code. The fee is calculated to be half of the annual permit fee of the annual permit that will be issued to the facility once compliance is achieved. This permit cannot be renewed but additional 1070 permits can be issued as needed to cover the entire compliance plan period. 3 This permit is valid for 24 months and is renewed on a biannual basis.
Schedule C
TABLE C-4915 for 22.602.045 Marine Cutting and Welding Fees 1,2,3,4 Temporary
Permit Duration | Length of Vessel (Feet)
(DAYS) | <40 | 40—59 | 60—89 | 90—129 | 130—199 | 200—299 | 300+
2 | $154 | $217 | $281 | $341 | $404 | $466 | $525
7 | $217 | $281 | $341 | $404 | $466 | $525 | $590
15 | $281 | $341 | $404 | $466 | $525 | $590 | $653
30 | $341 | $404 | $466 | $525 | $590 | $653 | $718
60 | $498 | $558 | $622 | $701 | $776 | $856 | $934
1 Fees apply to non-pre-approved applicants.
2 Fees for pre-approved applicants equal 1/2 of the fee identified in Table C-4915 for 22.602.045.
3 Any pre-approved applicant found to be in violation of permit conditions may be removed from the pre-approved applicant list and subject to non-pre-approved applicant fees and conditions.
4 Each applicant who receives a minimum of six permits (Code 4915) during a six-month period and is found to be in compliance with all permit conditions will be considered for pre-approved status upon request after the six-month period. Applicants who obtain fewer than six permits (Code 4915) during a six-month period will be considered for pre-approved status only after six permits have been issued and no permit violations are noted.
D. All permits listed under Schedules A, B, and C of this Section 22.602.045, except for those permits for which a time charge is indicated, have a base fee which incorporates the cost of an initial site inspection, one site reinspection if required, and related administrative time to determine compliance with the Seattle Fire Code. Any subsequent inspections will result in a fee based on a time charge, which shall be actual labor costs plus administrative overhead costs for field inspection and review time exceeding one hour. Such fees shall include overtime costs only when the work performed outside normal business hours (8 a.m. to 4:30 p.m. Monday through Friday) is required by the Seattle Fire Code or is performed at the request of the owner or responsible person or permit holder.
Permits for which a time charge is indicated include a base fee and a labor charge equal to actual labor costs plus administrative overhead costs for field inspection and review exceeding one hour before a permit is issued.
E. Temporary permits listed under Schedules A, B, and C will not be renewed on an annual basis.
F. Those permit applications that are required to be filed within time limitations specified under the Seattle Fire Code or by order of the Fire Chief or the Fire Chief's designee shall be subject to a late fee if not filed within the prescribed time period. Any work activity or operation regulated by the Seattle Fire Code that commences before obtaining the necessary permits shall require a permit at 1.5 times the fee of the original permit. Where a compliance plan agreement has been reached for a permitted activity, the fire code official is authorized to require temporary permits to be issued in lieu of an annual permit until full compliance with the Seattle Fire Code regulations for that activity is achieved. The fee for such temporary permits shall be based on the cost of an annual permit pro-rated for the time period the temporary permit is valid.
G. Payment for fixed rate Schedule C permit renewals that is received more than 30 calendar days but fewer than 91 calendar days past the permit expiration date shall be equal to 1.25 times the renewal fee. The renewal permit will be valid for only one year from the expiration date of the prior permit. Permits for which no renewal payment has been received within 90 calendar days following the permit expiration date will be cancelled. Permits that have been cancelled may be reinstated, effective from the expiration date, if the permit holder pays a late penalty of 1.5 times the fee for an original permit within 180 days of the expiration date. Thereafter, any person whose permit has been cancelled shall not be allowed to reinstate the cancelled permit, but shall be required to submit a new permit application and pay a late penalty of 1.5 times the fee for an original permit.
H. Payment for Schedule C worksheet-based permit fees listed under Schedule C as renewable, that is made more than 30 calendar days, but fewer than 91 calendar days, past the permit expiration date, shall be equal to 1.75 times the renewal amount. The renewal permit will be valid for only one year from the expiration date of the prior permit. Permits for which no renewal payment has been received within 90 calendar days following the permit expiration date will be cancelled. Permits that have been cancelled may be reinstated, effective from the expiration date, if the permit holder pays a late penalty of 1.25 times the fee for an original permit within 180 days of the expiration date. Thereafter, any person whose permit has been cancelled shall not be allowed to reinstate the cancelled permit, but shall be required to submit a new permit application and pay a late penalty of 1.25 times the fee for an original permit.
I. Unless specifically stated on the permit, no temporary use permit shall be valid for a term exceeding 12 months.
J. In special circumstances, permit fees may be adjusted, modified, or combined. Authority to adjust, modify, or combine such permit fees is limited to the Fire Chief, the Fire Marshal, and the Assistant Fire Marshal.
K. For permits listed in Schedules A, B, and C, when the Fire Marshal determines that standby fire personnel or subsequent inspections beyond those provided for in subsection 22.602.045.D are essential in order to obtain compliance with the Seattle Fire Code or for the public safety of an existing or proposed activity, building, or structure, or for the safety of the occupants thereof, actual costs for labor including applicable administrative overhead and other services shall be charged to the permit holder or other responsible party.
L. Fees for certification examinations are established in Schedule L. Each examination fee listed under Schedule L includes one test and one opportunity to retake the test under the following "re-test" conditions: the person taking the examination does not pass the examination the first time and the "re-test" occurs within 90 calendar days of the original test. Upon successfully passing a certification examination, and upon providing evidence of current State of Washington certification if required by State law for that certification type, the person who took the test will be certified by The City of Seattle for that certification type for one year. The certification may be renewed for two subsequent years at no cost to the licensee. The licensee will, however, need to demonstrate continued competence and continue to comply with State regulations where applicable as a condition of certification renewal. The renewal of the license will be denied if the Seattle Fire Department becomes informed and verifies that the licensee no longer meets the qualifications for the license. Testing is required once every three years.
Certification Fees
Effective January 1, 2025
Schedule L Table L for 22.602.045 Certification Examinations and Training
Certification Type | Description | Fee
Type AS-ITT(S) | Inspection and testing (except "acceptance testing") of water-based fire protection systems, State Level ITT (Inspection Testing Technician). | $515
Type AS-2(S) | Installation, inspection, testing, and maintenance of automatic sprinkler systems, State Level 2 (Residential-Level Sprinkler Fitters in Group R residential buildings up to and including four stories). | $515
Type AS-3(S) | Installation, inspection, testing, and maintenance of automatic sprinkler systems, State Level 3 (Journey-Level Sprinkler Fitters in all buildings). | $515
Type E-1 | Installation, inspection, testing, and maintenance of foam and water mist fire extinguishing systems. | $515
Type E-2 | Installation, inspection, testing, and maintenance of carbon dioxide fire extinguishing systems. | $515
Type E-3 | Installation, inspection, testing, and maintenance of clean agent, halon replacement, engineered wet chemical, and dry chemical fire extinguishing systems, including spray booths. | $515
Type E-4 | Installation, inspection, testing, and maintenance of pre-engineered wet kitchen hood suppression systems. | $515
Type EG-1 | Installation (non-electrical), inspection, testing, and maintenance of emergency generators. | $515
Type EG-ITM | Inspection, testing (except "acceptance testing"), and maintenance of emergency generators. | $515
Type FA-1 | Installation, programming, inspection, testing and maintenance of automatic fire alarm systems in any building. | $515
Type FA-ITM | Inspection, testing (except "acceptance testing"), and maintenance of automatic fire alarm systems. | $515
Type FP-1 | Installation (non-electrical), inspection, testing, and maintenance of fire pumps and controllers. | $515
Type FP-ITM | Inspection, testing (except "acceptance testing"), and maintenance of fire pumps and controllers. | $515
Type FEX-1 | All activities relating to portable fire extinguishers including those listed in Types FEX-2, FEX-3, and FEX-4. | $515
Type FEX-2 | Installation, inspection, testing, maintenance, charging, and recharging of portable fire extinguishers. | $515
Type FEX-3 | Hydrostatic testing of fire extinguisher cylinders. | $515
Type FEX-4 | Annual external examination of CO 2 or stored pressure fire extinguishers equipped with pressure indicators or gauges. | $515
Type SC-1 | Installation, inspection, testing, and maintenance of smoke control systems. | $515
Type SC-ITM | Inspection, testing (except "acceptance testing"), and maintenance of smoke control systems. | $515
Type STP-ITM | Inspection and testing (except "acceptance testing") of standpipe systems. | $515
Issuance of replacement certification card | $70
(Ord. 127139, § 2, 2024; Ord. 126936, § 1, 2023; Ord. 126711, § 1, 2022; Ord. 126522, § 4, 2022; Ord. 125707, § 2, 2018; Ord. 125189, § 1, 2016; Ord. 124649, § 1, 2014; Ord. 124044, § 1, 2012; Ord. 123444, § 1, 2010; Ord. 123090, § 6, 2009; Ord. 122849, § 1, 2008; Ord. 121668, § 1, 2004.)