For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 65.4 — Density controls

Code of Ordinances of the City of Huntsville, Alabama (Supp. No. 30 (codified through Ord. No. 26-196, adopted March 12, 2026) with enacted ordinances through Ord. No. 26-837 (September 24, 2026) applied from official council minutes and ordinance copies) · Huntsville Code of Ordinances, App. A, art. 65, § 65.4

Corpus is an independent public-information project, not the official City of Huntsville website. Stable reference: corpuslaw.us/code/bfd8a7bb-ab27-4fe2-853c-95efb6594755

65.4. - Density controls.

Within the boundaries of the slope development district, the following density requirements shall apply: _____ 65.4.1. Density Controls | Lower Slope Zone | Upper Slope Zone Minimum required lot size | 25,000 square feet | 40,000 square feet Maximum impervious cover per lot | 15% of lot area | 10% of lot area Maximum impervious cover per subdivision | 25% of subdivision area | 25% of subdivision area Maximum total building area | 10% of lot area | 8% of lot area Maximum disturbed area per lot* | 30% of lot area | 20% of lot area Minimum lot frontage | 20 feet | Minimum lot width | 60 feet | Minimum depth of front and rear yards | 50 feet from major arterials 15 feet from other streets or lots | Minimum width of each side yard | 10 feet | * See section 65.5.3. _____ 65.4.2. Application of impervious cover. Impervious cover is the sum of the areas within the boundary of a site that is covered with a surface material or treatment that substantially prohibits or impedes the infiltration of water into the ground. Maximum impervious cover for a lot or subdivision shall not exceed the number of square feet derived by multiplying the land area of such lot or subdivision by the appropriate impervious cover percentage. In addition to other impervious cover, all driveways and prepared parking areas shall be counted as impervious cover as shall all area lying below the roof of any structure. Impervious cover is not transferrable from one lot to another. 65.4.3. Nonresidential uses. Where a nonresidential use adjoins a residential use, a buffer at least 30 feet wide must be maintained in a natural state along such residential boundary. 65.4.4. Height limitations. The maximum number of stories for single-family residential buildings is 2½ and building height shall not exceed 45 feet at any point as measured vertically from the natural grade prior to development to the highest point of the roof. Building height for multifamily and nonresidential buildings shall not exceed 35 feet as measured vertically from the natural grade prior to development to the highest point of the roof. If roof-mounted mechanical or other equipment is present, such equipment shall be located or screened so as to not be visible from adjacent streets and properties; any such screening shall meet the applicable height limitation. Chimneys and antennae shall be excluded from the above height limitations. 65.4.5. Buildable area. Where there is any proposed multifamily construction or any subdivision of land within the slope development district, a building site plan or final plat is required. The final plat or building site plan shall include: (1) A clear delineation of the buildable area for each lot or building site. The buildable area shall satisfy all density requirements of the zoning ordinance as well as those regulations requiring setbacks from cultural and environmental features and from identified hazards. (2) The buildable area shall be large enough to permit the use of the allotted amount of building area for the lot and be free of slopes in excess of 35 percent and of all hazard zone conditions unless accompanied by certifications as specified in section 65.3.6. If the buildable area contains slopes between 25 percent and 35 percent, the plat must state that foundation restrictions apply. (3) A clear designation of the maximum amount of impervious cover in square feet allotted to each lot. (4) A clear designation of the maximum amount of building area in square feet allotted to each buildable area. (5) A clear designation of the minimum area of each lot, expressed in square feet, that must be retained in its natural state. 65.4.6. Off-street parking requirements. Two off-street parking spaces shall be provided for each residential unit. Nonresidential parking spaces shall be as required by section 70.1, off-street parking. 65.4.7. Permanent reservation of land. Development within the slope development district is eligible for modified density controls when the following conditions are satisfied: (1) At least 15 percent of the total area of the subdivision tract lying within the slope development district is permanently set aside prior to development to be held in its natural, undisturbed state except for hiking trails; and (2) The land so restricted is the steepest, or the most hazardous, or the most environmentally sensitive portion of the tract, so that the land remaining for development is that most suitable and safest for development. The unreserved portion of the tract lying within the lower slope zone may be developed according to the following density controls: Optional Density Controls | 15% to 29.9% of Land Reserved | 30% and Greater of Land Reserved Minimum required lot size | 21,000 square feet | 17,250 square feet Maximum impervious cover per lot | 18% of lot area | 22% of lot area Maximum impervious cover per subdivision | 25% of subdivision area | 25% of subdivision area Maximum total building area | 13% of lot area | 16% of lot area Maximum disturbed area per lot | 34% of lot area | 39% of lot area Minimum lot frontage | 20 feet | Minimum lot width | 50 feet | Minimum depth of front and rear yards | 50 feet from major arterials 15 feet from other streets or lots | Minimum width of each side yard | 9 feet | 8 feet

(Ord. No. 96-159, 4-25-1996)

Ask a question about Huntsville law

Corpus searches the Huntsville sections it holds and shows the ones that match, with their citations. Free, no sign-in.