Sec. 31-59. - IRC CHAPTER 11 ENERGY EFFICIENCY - amendments.

Only the following portions of CHAPTER 11, ENERGY EFFICIENCY, are amended: (a) Section N1101.6 (R202), Defined terms, is amended by adding the following: ELECTRIC VEHICLE SUPPLY EQUIPMENT (EVSE). The conductors, including the ungrounded, grounded, and equipment grounding conductors, and the electric vehicle connectors, attachment plugs, and all other fittings, devices, power outlets, or apparatus installed specifically for the purpose of transferring energy between the premises wiring and the electric vehicle. LOW-SLOPED ROOF. A roof having a slope less than 2 units vertical in 12 units horizontal. (b) Reserved. (c) Reserved. (d) Table 1102.4.1.1 (R402.4.1.1), Air Barrier, Air Sealing and Insulation Installation - Rim Joists and footnote b are revised to read as follows, with the rest of the table remaining unchanged. COMPONENT | AIR BARRIER CRITERIA INSULATION | INSTALLATION CRITERIA Rim joists | Rim joists shall include an air barrier. The junctions of the rim board to the sill plate and the rim board to the subfloor shall be air sealed. | Rim joists shall be insulated so that the insulation maintains permanent contact with the exterior rim board. b b. Insulation full enclosure is not required in unconditioned/ventilated attic spaces and at rim joists. (e) Section N1102.4.6 (R402.4.6), Electrical and communication outlet boxes (air-sealed boxes), is amended to read as follows: N1102.4.6 (R402.4.6) Electrical and communication outlet boxes (air-sealed boxes). Where air-sealed boxes are required by Table N1102.4.1.1 (R402.4.1.1), electrical and communication boxes shall comply with all of the following: 1. be tested in accordance with NEMA OS 4, Requirements for Air-Sealed Boxes for Electrical and Communication Applications; 2. have an air leakage rate of not greater than 2.0 cubic feet per minute (0.944 L/s) at a pressure differential of 1.57 psf (75 Pa); 3. be marked "NEMA OS 4" or "OS 4" in accordance with NEMA OS 4; and 4. be installed per the manufacturer's instructions and with any supplied components required to achieve compliance with NEMA OS 4. (f) A new Section N1102.6 (R402.6), Roof solar reflectance and thermal emittance, is added to read as follows: N1102.6 (R402.6) Roof solar reflectance and thermal emittance. Where not prohibited by the city environmentally sensitive lands ordinance (ESLO), low-sloped roof surfaces over conditioned and unconditioned spaces in Climate Zones 0 through 3 shall comply with one or more of the options in Table N1102.6 (R402.6). Exception: Portions of the roof that are covered by roof decks, vegetation, walkways, skylights, and solar energy systems are exempt from the requirements of Table N1102.6 (R402.6). TABLE N1102.6 (R402.6) MINIMUM ROOF REFLECTANCE AND EMITTANCE OPTIONS Three-year-aged solar reflectance index (SRI) of 64 Three-year-aged solar reflectance of 0.55 and a three-year aged thermal emittance of 0.75 (g) Section N1103.5.1.1.1 (R403.5.1.1.1), Demand recirculation water systems, is amended to read as follows: N1103.5.1.1.1 (R403.5.1.1.1) Demand recirculation water systems. Demand recirculation water systems are required when the length of hot water supply piping from the source of hot water to the furthest fixture fitting exceeds the specified length in Table N1103.5.1.1.1 (R403.5.1.1.1). Where the piping contains more than one size of pipe, the largest size of pipe within the piping shall be used for determining the maximum allowable length of piping before a recirculating hot water system is required. For the purpose of this section, the source of hot water shall be a water heater, boiler, circulation loop piping, distribution manifold, or heat-traced piping. Demand recirculation water systems shall have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance or sensing the flow of hot or tempered water to a fixture fitting or appliance. Table N1103.5.1.1.1 (R403.5.1.1.1) DEMAND RECIRCULATION WATER SYSTEM REQUIREMENT BASED ON PIPE SIZE AND LENGTH Nominal Pipe Size (inches) | Piping Length (feet) 3/8 inch line or less | > 50 feet 1/2 inch line | > 43 feet 5/8 inch line | > 32 feet 3/4 inch line | > 21 feet (h) A new Section N1104.4 (R404.4), Electric Vehicle (EV) charging infrastructure, is added as follows: N1104.4 (R404.4) Electric Vehicle (EV) charging infrastructure. New construction shall accommodate future installation and use of Electric Vehicle Supply Equipment (EVSE) in accordance with the National Electrical Code (NFPA 70). N1104.4.1 (R404.4.1) EV-capable charging. The main electrical service panel shall have a reserved space to allow installation of a full size 2-pole circuit breaker for future EV charging and shall be labeled "Future EV Charging". Where the electrical service panel is located beyond the perimeter of the garage wall, a raceway shall be installed from the electrical service panel to a location within the garage, where it shall terminate in a junction box or outlet and be labeled "Future EV Charging". Where resident parking is provided in a common parking area in lieu of individual dwelling unit garages or carports, EV charging infrastructure shall comply with Section C405.13 of the City Energy Code (IECC). (i) Table N1105.2 (R405.2), Requirements for Total Building Performance - Building Thermal Envelope and Electrical Power and Lighting Systems, are revised by adding a new line for Sections N1102.6 (R402.6) and N1104.4 (R404.4) as follows: TABLE N1105.2 (R405.2) REQUIREMENTS FOR TOTAL BUILDING PERFORMANCE Building Thermal Envelope N1102.6 (R402.6) | Roof solar reflectance and thermal emittance. Electrical Power and Lighting Systems N1104.4 (R404.4) | Electric vehicle charging infrastructure (j) Table N1106.2 (R406.2), Requirements for Energy Rating Index - Building Thermal Envelope and Electrical Power and Lighting Systems, are revised by adding a new line for Sections N1102.6 (R402.6) and N1104.4 (R404.4) as follows: TABLE N1106.2 (R406.2) REQUIREMENTS FOR ENERGY RATING INDEX Building Thermal Envelope N1102.6 (R402.6) | Roof solar reflectance and thermal emittance. Electrical Power and Lighting Systems N1104.4 (R404.4) | Electric vehicle charging infrastructure (k) Section N1108.2 (R408.2), Additional efficiency package options, is amended to read as follows: N1108.2 (R408.2) Additional efficiency package options. Additional efficiency package options for compliance with Section N1101.13.5 are set forth in Sections N1108.2.1 through N1108.2.6. (l) A new Section N1108.2.6 (R408.2.6), On-site renewable energy option, is added as follows: N1108.2.6 (R408.2.6) On-site renewable energy option. Provide an on-site renewable energy generation system that meets one of the following: 1. Provides a total rated capacity of not less than 2 watts per square foot (22 W/m 2 ) of the total conditioned floor area. 2. Provides not less than 50 percent of the estimated annual energy use within the building for mechanical, service water-heating, lighting and electric vehicle charging.

(Ord. No. 4575, § 1(Res. No. 12499, § 1(Exh. A)), 12-6-22)

Ask a question about Scottsdale law

Corpus searches the Scottsdale sections it holds and shows the ones that match, with their citations. Free, no sign-in.