21.16.260 - Construction requirements and specifications.

A. Materials and workmanship in connection with the installation of any side sewer shall be as required by this chapter, the City's Standard Plans and Specifications, Chapters 22.800 through 22.808 of the Seattle Municipal Code, all associated rules issued by the Director, and as designated by the Director of Seattle Public Utilities. If any requirements or standards conflict, or if special circumstances exist, the Director of Seattle Public Utilities will determine which requirements or standards will be applicable. B. Unless authorized by the Director of Seattle Public Utilities, an owner or occupant who is required, or wishes, to connect to a public sewer shall be required to build a main sewer line extension if a public sewer is not accessible within an abutting public place. C. Unless authorized by the Director of Seattle Public Utilities, no more than one building shall be connected to a side sewer. If more than one building is allowed to connect to one side sewer, in addition to requirements in Section 21.16.250, the pipe downstream of the point of shared connection shall be not less than 6 inches in diameter. D. All multiple-unit buildings, industrial buildings, and commercial buildings shall be connected with not less than 6 inch diameter pipe on private property. E. Unless authorized by the Director of Seattle Public Utilities, all side sewers shall be constructed with not less than 2 percent grade and not more than 100 percent grade. F. Unless authorized by the Director of Seattle Public Utilities, all side sewers shall have not less than 60 inches of cover at the curbline or in a public alley, 30 inches of cover at the property line, and 18 inches of cover on private property. G. Unless authorized by the Director of Seattle Public Utilities, all side sewers serving one dwelling unit shall have minimum pipe size of 4 inches in private property and 6 inches in the public place. H. Ductile or cast iron pipe shall be used for all side sewers crossing over water mains for a distance of at least 5 feet measured perpendicular from the center of the water main. Side sewer lines must be laid at least 6 inches below and 1 foot away from any water service line or water main, unless ductile or cast iron pipe is used for the side sewer. I. Whenever a side sewer is to be abandoned, said sewer shall be capped as close to the property line as possible without interrupting service to any other building.

(Ord. 123494, § 29, 2010; Ord. 119688 § 3, 1999; Ord. 118605 § 3, 1997; Ord. 118396 § 106, 1996; Ord. 114298 § 27, 1988; Ord. 97016, § 26, 1968.)

Ask a question about Seattle law

Corpus searches the Seattle sections it holds and shows the ones that match, with their citations. Free, no sign-in.