Boarding.
R.I. Gen. Laws § 23-27.3-124.6
in effect23-27.3-124.6. Boarding.
(a) Any building or structure which is ordered secure for any reason by the building official
shall be boarded in accordance with the following specifications:
(b) All openings (including doors and windows) from cellar to second floor inclusive,
and all windows above the second floor leading to fire escapes, porches, or structural
appurtenances on all floors must be covered from the exterior with a minimum of one-half
inch (½") thick exterior grade plywood secured with screws of minimum length 15/8"
or 2" (6d) ring shank nails placed 12 inches on center around the perimeter of the
opening. Plywood shall be fitted so it rests snugly against the exterior frame butting
up to the moulding or siding. All other windows must be secured in a similar manner
with3/8” plywood from either the exterior or interior of the building.
P.L. 1976, ch. 256, § 1.