202 General Definitions.
Cedar Rapids Municipal Code § 37.09
in effect37.09 - 202 General Definitions.
Section 202 entitled "GENERAL DEFINITIONS" shall by modified by adding the following definitions:
Alarm user. Any person or business on whose premises a fire alarm system or sprinkler system is located within the City of Cedar Rapids, Iowa.
Central business district. The City of Cedar Rapids area from the Cedar River to and including the easterly side of 5"' St SE & from the southerly side of C Ave NE to the northerly side of B"' Ave SE.
Charcoal grill. An outdoor cooking device using solid fuels as a heat source for cooking food; examples not limited to charcoal, wood, wood chips, coal, or coke.
Confined space. A space that (1) is large enough and so configured that an employee can bodily enter and perform assigned work; and (2) has limited or restricted means for entry or exit, such as tanks, vessels, silos, storage bins, hoppers, vaults, and pits; and (3) is not designed for continuous employee occupancy.
Confined space rescue team. Trained Fire Department personnel designed to rescue employees from permit-required confined spaces OR a confined space rescue team which complies with all Federal, State, and Local requirements.
False alarm. The willful and knowing initiation or transmission of signal, message, or other notification of an event of fire when no such danger exists, or an alarm caused by careless use, improper maintenance, or negligence of a fire alarm system or sprinkler system, or an alarm defined as an unwanted alarm by NFPA 72, which causes response of fire department apparatus and personnel.
Multi-family complex: A residential occupancy such as an apartment building, condominium, townhouse, or similar buildings with similar use.
Permit-required confined space. A confined space that has one or more of the following characteristics; (1) contains or has a potential to contain a hazardous atmosphere; (2) contains a material that has the potential for engulfing an entrant; (3) has an internal configuration such that an entrant could be trapped or asphyxiated by inwardly converging walls or be a floor which sloped downward and tapers to a smaller cross-section; or (4) contains any other recognized serious safety or health hazard.
Qualified person. Sprinkler or Fire Alarm System design. A qualified person for plan design shall have a minimum National Institute for Certification in Engineering Technologies [NICET] Level Ill certification for fire sprinkler system design OR have NICET Level Ill certification for Fire Alarm System design. Other qualifications for sprinkler or fire alarm system design may be approved by the fire code official, including a licensed engineer with experience in life safety system design.
Sprinkler system installation or inspection, testing, and maintenance. A qualified person for Automatic Sprinkler System installation shall have a minimum National Institute for Certification in Engineering Technologies [NICET] Level II certification for Automatic Sprinkler System installation. A qualified person for Automatic Sprinkler System inspection, testing, and maintenance shall have a minimum NICET Level II certification for Automatic Sprinkler System Inspection and Testing of Water Based Systems. Other qualifications for Fire Sprinkler System installation or inspection, testing and maintenance may be approved by the fire code official, including a person who successfully completes a five-year approved apprenticeship program as a journeyman sprinkler fitter (e.g., American Fire Sprinkler Association [AFSA], National Fire Sprinkler Association [NFSA]).
FIre alarm system installation or inspection, testing, and maintenance. A qualified person for Fire Alarm System installation shall have a minimum National Institute for Certification in Engineering Technologies [NICET] Level II certification for Fire Alarm Systems OR be factory trained and certified for the specific Fire Alarm System installation. A qualified person for Fire Alarm System inspection, testing, and maintenance shall be NICET Level II certified OR be factory trained or certified for the specific Fire Alarm System OR be International Municipal Signal Association Fire Alarm Certified OR be a trained and qualified person employed by an organization listed by a national testing laboratory for the servicing of fire alarm systems. Other qualifications may be approved by the fire code official.
(039-24)