For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 20.12.037 — Special Studies

Long Beach Municipal Code (Supp. No. 53, Update 1: codified through Ordinance No. ORD-26-0027, enacted October 13, 2026) · Long Beach Municipal Code § 20.12.037

Corpus is an independent public-information project, not the official City of Long Beach website. Stable reference: corpuslaw.us/code/c27d3a98-d8ee-499d-82bc-b74b3fb65460

20.12.037 - Special Studies.

In addition to the tentative map and accompanying data, supplemental materials may be required to be filed depending on the site's location and potential impact on various resources or consistency with City plans and policies: A. A phase 1 cultural resources inventory to identify any potential archaeological, paleontological, or historic on-site resources, including historic artifacts and structures, and tribal cultural resources. B. In potential noise sensitive areas identified in the General Plan Noise Element, specific site analysis by an acoustical engineer or other approved professional with qualifications in acoustic design may be required by the Community Development Director. The study shall define the noise exposure problems, conclusions, and recommendations for corrective or mitigating measures, when necessary, and opinions and recommendations covering the suitability of the site for development. C. Sewer Capacity Study. A preliminary sewer capacity study (prepared by a qualified engineer registered in this State) based on either sewer system model results, or flow monitoring with a sewer capacity study approved by the Long Beach Water Department (LBWD). The capacity study shall ensure that the sewer system can accommodate a proposed development, and if not, identify needed improvements required for the development. D. Hydrology Report. In certain areas where there is a known high water table, a hydrologic report shall be prepared that evaluates the existing water table and identifies potential issues with new development. The report shall be prepared by a qualified geologist or hydrologist and shall include recommendations for site preparation, foundation design, and other strategies to offset potential impacts. E. Septic Systems. Septic Tanks and Leach Fields shall be abandoned or removed in accordance with plans approved by the Community Development Department and the Health Department. All sewage shall be disposed of by an approved connection to the appropriate Public sewer system. F. Potable and/or Recycled Water System Analysis: A preliminary potable and/or recycled system analysis shall be prepared by a qualified engineer to evaluate existing system capacity in the area and improvements needed to serve the new demand created by the project to the approval of LBWD. G. Maps for condominium projects shall indicate the address of the property and the number, size and location of proposed dwelling units, parking spaces, and private or public open spaces. For all condominium projects, the floor area of each floor shall be shown in proper scale and location together with the plan view of each ownership unit. Further information regarding condominium projects and other common interest subdivisions is included in Chapter 20.30.

(ORD-23-0051 § 1(Exh. A), 2023)

Ask a question about Long Beach law

Corpus searches the Long Beach sections it holds and shows the ones that match, with their citations. Free, no sign-in.