Sec. 49-1319. - Vent stacks.
A vent stack or main vent shall be installed observing the following provisions: (a) Shall terminate independently in the open air above the roof of the building or shall be connected with the stack vent as prescribed in section 49-1315. (b) Shall be run downward, full size (no reduction in size) and be connected with the soil or waste through, at, or below the lowest horizontal waste branch or with the building drain. (c) Whenever back vents, relief vents, or other branch vents are required on two or more floors, the vent stack shall be installed with soil or waste stacks
(Ord. No. 40524, § 1, 10-20-15)