For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 19.120.050 — Design standards and guidelines

Riverside Municipal Code (Supp. No. 33: codified through Ordinance No. 7776, enacted June 23, 2026) · Riverside Municipal Code § 19.120.050

Corpus is an independent public-information project, not the official City of Riverside website. Stable reference: corpuslaw.us/code/c30a5412-8ebf-48c9-8598-67c188c9a1e4

19.120.050 - Design standards and guidelines.

The purpose of this section is to facilitate high quality development within mixed-use zones with an emphasis on innovative project design, infill development, and reuse of existing structures. These standards address site planning and building design and are in addition to the development standards in Section 19.120.060 (Development Standards) of this chapter. A. Setbacks. 1. The front setback area shall include landscaping and/or a hard-surface expansion of the public sidewalk. 2. Along street frontages in the MU-U Zone, if any portion of the building is set back 15 feet or greater at the ground level, at least one of those setback areas shall include non-residential outdoor uses consisting of plazas, patio dining, displays, public art, or entry courts. B. Building siting, orientation and entrances. 1. Buildings shall be sited and oriented adjacent to the following, in order of priority: a. Public right-of-way; b. Primary internal streets and pedestrian walkways, not including drive aisles; c. Common usable open space; d. Secondary internal streets or drive aisles. 2. Building entrances. a. Primary building entrance(s) and commercial storefronts shall be oriented toward the following (listed in priority order: (1) Public right-of-way; (2) Primary internal streets and pedestrian walkways, not including drive aisles; (3) Plazas or common usable open space; (4) Secondary internal streets or drive aisles. b. Pedestrian walkway connections to building entrances shall include special paving treatment, color or materials. c. At least one of the following shall be used to demarcate primary building entrances: awnings, canopies, overhangs, recesses, porticos, and/or arcades. C. Building step back. Buildings shall provide a transition between urban and residential areas (Figure 19.120.050 C. - Building step back). Taller elements of the building shall increasingly step back from adjacent single-family residential zones. No portion of the building, excluding parapets, shall extend above an imaginary plane drawn at the property line that is adjacent to the RA-5, RC, RR, RE, and R-1 Zones, and extended at an angle of 45 degrees toward the center of the property. Figure 19.120.050 C. Building step back [image omitted; see the official code] D. Building appearance. 1. The design of mixed-use development shall incorporate the following provisions: a. All building elevations visible from the public right-of-way shall be modulated at least every 50 feet by changes in building mass, facade treatment, fenestration pattern, roof form or other architectural features. b. Where residential and nonresidential uses are located within the same building, the nonresidential component shall be differentiated from residential component through changes in exterior finish material, floor height, glazing pattern, building wall plane, and/or horizontal projection. c. A minimum of three exterior cladding or finish materials shall be used per building. Variation in color, texture or application method among the same material shall not be considered a different material. d. Building facades shall be designed to define and articulate each vertical module of residential units, using at least two of the following: (1) Providing a variation in the wall plane (projection or recess) a minimum of two feet in depth between the modules; (2) Varying a minimum of two of the following architectural elements between modules: window recess depth, roof shape, window shape, stoop detail, and/or railing type; (3) Providing porches and balconies; e. Windows visible from the public right-of-way shall be recessed a minimum of four inches. E. Privacy for residential units. 1. The windows of a residential unit shall not directly align with the windows of the unit of an adjacent building; but shall be offset by a minimum of ten feet from window edge to opposing window edge (Figure 19.120.050 E. - Privacy for Residential Unit(s). 2. Patios, balconies or similar openings of a residential unit shall not directly align with that of the unit of an adjacent building; but shall be oriented or offset by a minimum of 15 feet from opening edge to opposing opening edge (Figure 19.120.050 E. - Privacy for Residential Units). Figure 19.120.050 E. Privacy for Residential Units [image omitted; see the official code] F. Vehicle circulation and access. 1. On-site vehicular circulation serving non-residential uses shall be open and not obstructed by the use of fences and gates. Private residential parking areas may be secured and gated. 2. Vehicular entrances, including private garages, carports and parking structure entrances, shall be oriented toward the following (listed in priority order): a. Public alleys; b. Secondary internal streets or drive aisles; c. Primary internal streets; d. Public streets (except private garages and carports shall not take direct access from a public street). G. Pedestrian walkways. 1. On-site pedestrian walkways shall be provided between adjacent uses within the project and align with walkways on neighboring properties where pedestrian connections exist. 2. Pedestrian walkways shall connect residential and non-residential uses in the project, common open space, plazas and courtyards, parking areas and public sidewalks. 3. Pedestrian walkways shall be clearly demarcated from vehicular circulation areas through the use of different surfacing materials if at the same finished elevation; or shall be a raised sidewalk separated by a curb with a minimum height of six inches; and shall be ADA compliant. H. Fences and walls. In addition to the standards and requirements of Chapter 19.550 (Fences, Walls, and Landscape Materials) the following standards shall apply: 1. Fences and/or walls located anywhere between the primary building and the public right-of-way shall not exceed the following: a. Three feet in height for solid fences and walls; b. Four feet in height for openwork or combination solid and openwork fences and walls provided that the openwork portion of the fence or wall above a height of three feet shall be no more than one part solid to three parts open with no portion of the solid wall, excluding pilasters, extending above three feet; c. Fences and/or walls that enclose common usable open space amenities such as swimming pools and playgrounds, and excluding passive landscape areas, shall have a maximum height of six feet and, if solid, shall match the exterior finish material and color of the primary building(s). I. Permitted materials for fences and/or walls shall include decorative masonry split face block, brick, natural stone, precast concrete panels, stucco, wrought iron, aluminum, wood, chemically treated or naturally resistant to decay. J. Residential usable open space. 1. Common and private usable open space shall be provided as set forth in Table 19.120.040 C. 2. Common open space areas shall include the minimum number and type of amenities based on the project's size as set forth in 19.100.070 A. (Usable open space). 3. Private useable open space shall be contiguous to the unit served. 4. In the MU-V and MU-U Zones, private and common usable open space may be provided on the roofs of buildings and parking garages. K. Outdoor display and storage. Commercial outdoor display and storage shall not be permitted except as specified in Chapters 19.500 (Outdoor Display of Incidental Plant Materials), 19.505 (Outdoor Display and Sales) and 19.510 (Outdoor Storage). L. Trash receptacles and enclosures. 1. The trash storage container areas for residential and non-residential uses shall be separate. 2. The provisions of Chapter 19.554 (Trash/Recyclable Materials Collection Area Enclosures) regarding requirements for the screening of trash receptacles shall apply. M. Mechanical equipment screening. The provisions of Chapter 19.555 (Outdoor Equipment Screening) regarding required screening of mechanical equipment shall apply.

(Ord. No. 7701, §§ 6—8, 2025; Ord. 7592 § 3(Exh. C), 2022; Ord. 7573 § 1(Exh. A), 2021; Ord. 7331 § 6, 2016; Ord. 6966 § 1, 2007)

Ask a question about Riverside law

Corpus searches the Riverside sections it holds and shows the ones that match, with their citations. Free, no sign-in.