MF-1 (Multifamily - Low Density) district.
Round Rock Zoning and Development Code, art. II, § 2-22
in effectSec. 2-22. - MF-1 (Multifamily - Low Density) district.
(a) Purpose. To establish and preserve areas of medium intensity land use primarily devoted to low density multifamily residential development that is compatible with abutting and nearby single-family neighborhoods.
(b) Permitted uses. Uses permitted in the MF-1 district may be found in Sec. 2-25.
(c) Lot and building dimensional standards. Property and buildings in the MF-1 district shall conform to the standards found in Sec. 2-26, with the following supplementary notes:
(1) The minimum lot area shall be 10,000 sq. ft. for buildings with four (4) or fewer units and 20,000 sq. ft. for buildings with more than four (4) units.
(2) Accessory buildings shall be setback 20 feet from abutting SF and TF zoned property when a pre-cast concrete panel fence is used and 15 feet from abutting SF and TF zoned property when a masonry fence is used.
(3) For all properties abutting SF and TF zoned property a minimum 15-foot landscape buffer is required. No other use is permitted within the buffer.
(4) A side setback of zero (0) feet is permitted only for internal attached units with a common wall. End units shall have a 10-foot side setback.
(d) Supplementary development standards. In addition to the standards found in chapter 8 of this Code, the following regulations apply to the MF-1 district:
(1) Unit limit. Density shall not exceed 12 units per acre. No more than 120 dwelling units shall be permitted in any single apartment complex. No more than 12 dwelling units shall be permitted in any single residential structure.
(2) Low density multifamily separation requirement. No more than 120 apartment units can be grouped on the same or separate but adjacent lots unless they are separated by open space, natural features such as a creek or stand of trees, or OF or C-2 zoning (with the exception of a gas station use). If the separation requirement is fulfilled in the form of open space, it shall comply with the following standards:
a. The open space shall measure no smaller than 100 feet wide on average and at no point shall be less than 75 feet wide.
b. The open space shall contain a minimum of one (1) large tree and one (1) medium tree for every 5,000 square feet.
c. The open space may be used as space for an outdoor recreational amenity for the abutting low density multifamily complexes.
d. The open space shall comply with all compatibility standards.
(3) Amenities. At least one (1) amenity accessible to all residents shall be provided for each low density multifamily complex with 30 or more dwelling units. Amenities shall be included at the following rate:
Number of dwelling units | Minimum number of amenities
0—29 | 0
30—59 | 1
60—89 | 2
90—120 | 3
Amenities include but are not limited to the following:
a. Playground equipment,
b. Fenced dog park, to measure no smaller than 2,500 square feet, with minimum depth 25 feet,
c. Private fitness facility*,
d. Picnic area, to contain no fewer than two tables and two cooking grills,
e. Swimming pool,
f. Business center, to contain no less than one computer, printer, fax machine, copier, and scanner (printer, fax machine, copier, and scanner may be integrated into a single device), available for resident use*,
g. Tennis court,
h. Basketball court,
i. Volleyball court,
j. Kitchen available for resident use*,
k. Social room available for resident use*,
* These amenities may be located in the amenity center and each one qualifies toward the amenity requirement.
(4) Garage requirements. Garages shall comply with the following standards:
a. Garages shall not be located within 15 feet of any SF or TF property.
b. Only garages that are integrated within the dwelling structures shall be permitted to face a public street, and they shall not extend beyond the front building facade of the dwelling structure.
c. Street-facing garage doors shall not comprise more than 50 percent of the facade width of each dwelling unit.
d. Street-facing driveways located adjacent to one another shall be separated by a landscaped area measuring a minimum of six (6) feet wide.
e. Detached garages are prohibited in the front street yard and shall be constructed with the same materials and with similar architectural features as the residential structure.
f. No garage door shall face a SF or TF district or lot within 200 feet, with the exception of SF or TF lots located across an adjacent public street.
g. Garages contained within a detached structure shall contain no more than eight (8) parking spaces.
(5) Additional parking. Additional parking that is not within a garage is prohibited in any street yard, with the exception of parking on driveways in front of garages that have been integrated into the dwelling structures. Additional parking shall not be located within 15 feet of any SF or TF property line.
(6) Landscaping. In addition to the regulations located in Sec. 8-10, a linear area with improved soils and planted with annuals, perennials, and small shrubs shall be installed and maintained along the foundation of all elevations facing the public right-of-way. This area shall measure a minimum of four (4) feet wide on average, and at no point shall be less than two (2) feet wide. This requirement shall not apply where sidewalks and driveways meet the building perpendicularly.
(7) Lot fencing. A view fence in the front street yard shall be permitted to reach a height of six (6) feet.
(8) Light fixture height. The height of a light fixture shall not exceed 20 feet in parking areas and 12 feet in pedestrian areas.
(e) Low density multifamily design standards. The following design standards apply to all residential buildings in the MF-1 (Multifamily - Low Density) district. Other recognized architectural designs may be approved by the zoning administrator in order to permit a more flexible, compatible or creative design:
(1) Building orientation. Building elevations that face a public street shall have at least 15 percent of the wall facing the street consist of windows and/or entrance areas.
(2) Building elevation variation. Any wall in excess of 40 feet in length shall include offsets of at least two feet in depth. There shall be no less than one offset for every 30 feet of horizontal length.
(3) Building design variation. The design of individual buildings within multi-building developments shall vary. No two identical buildings shall be located adjacent to one another.
(4) Exterior wall color finishes. Day-Glo, luminescent, iridescent, neon or similar types of color finishes are prohibited.
(5) Exterior stairwells. Exterior stairwells shall be permitted provided that the design, color, and materials complement the architectural theme of the dwelling structure. Final exterior stairwell design shall be approved by the zoning administrator.
(6) Glass. Mirrored glass with a reflectivity of 20 percent or more is prohibited on the exterior walls and roofs of all buildings and structures.
(7) Windows. Windows shall be incorporated on every elevation that is visible from a public street. Windows shall be provided with trim and shall not be flush with exterior wall treatment. Windows shall be provided with an architectural surround at the jamb, header and sill.
(8) Roofing. Portions of the roof shall be permitted to be flat to provide for mechanical equipment wells or roof decks, provided that such flat areas are screened by pitched sections of the roof.
(9) Special design features. A minimum of five (5) features from the following list shall be incorporated into the building design:
a. Bay window.
b. Arched window.
c. Gable window.
d. Oval or round windows.
e. Shutters.
f. Arched entry, balcony or breezeway entrance.
g. Stone or brick accent wall.
h. Decorative stone or brick band.
i. Decorative tile.
j. Veranda, terrace, patio, porch or balcony.
k. Projected wall or dormer.
l. Variation of roof lines on the building.
m. Decorative caps on chimneys.
n. Other feature as approved by the zoning administrator.
(f) Multifamily house design standards. A multifamily house is a structure that is designed to appear as a large, custom-built single-family home but may contain up to six (6) dwelling units inside. Individual dwelling units are indistinguishable within the larger building form. Design aspects not specifically addressed below shall be regulated by subsection (e) above. Other recognized architectural designs may be approved by the zoning administrator in order to permit a more flexible, compatible or creative design.
(1) Access. Each building shall have a singular principal entryway on the front that is in scale with the overall mass of the building. Secondary entrances shall be located along the rear or side of the building.
(2) Additional setback requirements. Chimneys, roof overhangs, bay windows, and other architectural elements approved by the zoning administrator may encroach into the setback by a maximum of 24 inches. Porches and patios may encroach into the front setback by up to eight (8) feet and into the side setback by up to five (5) feet.
(3) Porch/patio/balcony requirement. Each unit shall have a minimum of 60 square feet of outdoor living space in the form of a patio, porch or balcony adjacent to its principal living space. The minimum depth of the space shall be six (6) feet. This space shall qualify as one of the required special design features.
(g) Design standard incentive. A Developer shall be allowed to have multi-family housing in the MF-1 district with an increased density from 12 units per acre to 14 units per acre; have no limit on the number of units per building; and shall be permitted to have only 50 percent of parking enclosed within a garage, so long as all of the following conditions are met:
(1) The exterior finish of all buildings shall be natural stone, simulated stone, brick, stucco, fiber cement siding (excluding flat, unarticulated panels), glass or architecturally finished steel or metal, except for doors, windows, accents and trim. The use of other materials shall be limited to accent features. Other wall finishes or recognized architectural styles not explicitly permitted by this section may be approved in writing by the zoning administrator.
(2) The ground floor of all buildings shall be a minimum of 75 percent natural stone, simulated stone, or brick.
(3) A minimum of two different materials shall be used on each structure, and each material used shall comprise no less than 20 percent of the exterior wall finish.
(4) No more than 33 percent of the building façade may be fiber cement siding or architecturally finished steel or metal.
(5) Roofing materials shall consist of 25-year architectural dimensional shingles, tile (clay, cement, natural or simulated stone), non-reflective prefinished metal, or reflective metal such as copper or other similar metals as approved by the zoning administrator.
(h) Applicability to PUDs. Design and development standards specifically addressed in planned unit developments (PUDs) adopted prior to October 25, 2012 shall prevail.
(Ord. No. O-2019-0463, § X, 11-26-2019; Ord. No. O-2020-0158, § III, 6-11-2020)
Source: City of Round Rock, Texas, Code of Ordinances (Municode Library, library.municode.com)URL: https://library.municode.com/tx/round_rock/codes/code_of_ordinances?nodeId=PTIIIZODECO_CH2ZODIUSRE_ARTIIREDI_S2-22MUOWDEDIFetched: 11/16/2026