§ 153.03 — Modifications to the 1999 Ohio Residential Code for One, Two, and Three Family dwellings

Code of Ordinances, City of Dayton, Ohio (Supp. No. 36: codified through Ordinance No. 32173-25, passed December 31, 2025) · Dayton City Code § 153.03

Corpus is an independent public-information project, not the official City of Dayton website. Stable reference: corpuslaw.us/code/c3a7cb11-0b66-46d5-b703-b8d94fd28aff

Sec. 153.03. - Modifications to the 1999 Ohio Residential Code for One, Two, and Three Family dwellings.

The following provisions replace Chapter One of the 1999 Ohio Residential Code for One, Two, and Three Family Dwellings in their entirety: CHAPTER 1 SECTION 101 TITLE 101.1 Title. These provisions shall be known as the Ohio Residential Code for One, Two, and Three Family Dwellings, shall be cited as such, and shall be referred to in Sections 101 through 119 as "this code." SECTION 102 PURPOSE 102.1 Minimum standards. The purpose of this code is to provide minimum standards for the protection of life, limb, health, property, environment and for the safety and welfare of the consumer, general public, and the owners and occupants of residential buildings regulated by this code. SECTION 103 SCOPE 103.1 Application. The provisions of this code apply to the construction, addition, prefabrication, alteration, repair, use, occupancy and maintenance of detached one, two, and three family dwellings and one-family townhouses not more than three stories in height, and their accessory structures. SECTION 104 AUTHORITY 104.1 General. The building official is hereby authorized and directed to administer and enforce all of the provisions of this code. 104.2 Referenced standards. The standards referenced in this code and listed in Chapter 49 shall be considered part of the requirements of this code to the prescribed extent of each such reference. Where differences occur between provisions of this code and referenced standards, the provisions of this code shall apply. SECTION 105 ENTRY 105.1 Authority to enter. Upon presentation of proper credentials, the building official or his or her duly authorized representatives shall be permitted to enter at reasonable times any building, structure or premises in the jurisdiction to perform any duty imposed upon the building official by this code, or whenever there is reasonable cause to believe that there exists in the building or premises a violation or condition which is unsafe, dangerous or hazardous. If entry is refused, the building official shall have recourse to the remedies provided by law to secure entry. SECTION 106 VIOLATIONS, PENALTIES, AND ADJUDICATION ORDERS 106.1 Unlawful action. It shall be unlawful for any person, partnership, joint venture, firm or corporation, whether as owner, lessee, sublessee or occupant, to erect, construct, enlarge, alter, repair, improve, remove, convert, demolish, equip, use, occupy or maintain any one two, or three family dwelling in the jurisdiction or cause or permit the same to be done, contrary to or in violation of any of the provisions of this code. 106.2 Violations. It is hereby declared that any violation of this code constitutes a public nuisance, and in addition to any other remedies provided by this code for its enforcement, the jurisdiction shall be permitted to bring civil suit to enjoin the violation of any of the provisions of this code. 106.3 Partial invalidity. If for any reason any one or more sections, sentence clauses or parts of this code are held invalid, such judgment shall not affect, impair or invalidate the remaining provisions. 106.4 Penalty. Any person, partnership, joint venture, firm or corporation violating any of the provisions of this code shall be guilty of a misdemeanor and each such person shall be deemed guilty of a separate offense for each and every day or portion thereof during which any violation of any of the provisions of this code is committed, continued or permitted, and upon conviction of any such violation such person shall be punishable by a fine, or by imprisonment, or by both such fine and imprisonment as established by local applicable laws. 106.5 Adjudication order, required before legal proceedings. Before any department or agency of the city attempts to enforce this code, by any remedy, civil, or criminal, it shall issue an adjudication order. Such orders shall be prepared and executed in accordance with the Ohio Building Code. SECTION 107 RIGHT OF APPEAL 107.1 General. In order to hear and decide appeals of orders, decisions or determinations made by the building official relative to the application and interpretation of this code, there shall be a Board of Appeals consisting of members who are qualified by experience and training to pass upon matters pertaining to building construction and who are not employees of the jurisdiction. The building official shall act as secretary to the board, but shall have no vote on any matter before the board. The Board of Appeals shall be appointed by either the Montgomery County Board of Commissioners or the Greene County Board of Commissioners, as applicable, and shall hold office at their pleasure. The board shall adopt rules of procedure for conducting its business and shall render its decisions and findings in writing to the appellant with a duplicate copy to the building official. 107.2 Limitations of Authority. The Board of Appeals shall have no authority relative to interpretations of Chapter 1, the administrative provisions of this code, nor shall the board be empowered to waive requirements of this code. 107.2.1 Residential Board of Appeals. In order to hear and decide appeals of orders, decisions or determinations made by the building official relative to the application and interpretation of this code, there shall be Boards of Appeals established by the Montgomery County Commission and the Greene County Commission to hear all appeals of each jurisdiction adopting this Code, including the City of Dayton, within each respective county, in accordance with Sections 107.2 through 107.10. 107.2.2 Board. Upon adoption of this code by the Greene County Commission or the Montgomery County Commission, there is hereby created a Residential Board of Appeals in that county, hereinafter referred to as "the Board". The Greene County Board shall have the power to adopt and promulgate rules and regulations interpreting the provisions of this Code and the Flood Damage Prevention Regulation (see Part Nine of the Greene County amendments to the Code). The Montgomery County Board shall have the power to adopt and promulgate rules and regulations interpreting the provisions of this Code and the Southwest Ohio Fire Safety Council's Unified Fire Code. 107.3 Qualifications of Members. The Board shall consist of five (5) members as follows: 1. One fire official; 2. One builder; 3. One architect or engineer, registered as such in Ohio; 4. One attorney, licensed to practice in Ohio; and 5. One building official. Each member shall be appointed by the appropriate county commission for a term of five (5) years, or until his successor is appointed, except that appointments to fill vacancies arising in mid-term shall be only for the unexpired portion of such terms. 107.3.1 Nomination Sources. In Montgomery County the following organizations shall provide nominations for that county's board. The fire official shall be nominated by the Southwest Ohio Fire Safety Council. The builder shall be nominated by the Home Builders' Association of Dayton and the Miami Valley. The architect or engineer shall be nominated by the City of Dayton, the City of Kettering, or Montgomery County, in turn, by alphabetical order. The attorney shall be nominated to Montgomery County's Board by the other jurisdictions within Montgomery County which have adopted this Code, in turn, by alphabetical order. The building official shall be nominated by the Miami Valley Building Officials' Council. Members of both Boards shall have a minimum of six years of building design, construction, or inspection experience, except the attorney, who shall have six years legal experience. 107.4 Chairman and Secretary. The Board shall appoint one of its members to serve as its Chairman, and one as Vice-Chairman. The Board shall appoint a person to act as secretary for the Board who shall keep a detailed record of all Board proceedings. In Montgomery County the terms of service by the Chairman, Vice-Chairman, and Secretary shall be renewable in one year. The Secretary need not be a member of the Board. 107.5 Disqualification. No member of the Board shall discuss or pass judgement on any question involving work on which he or his employer is or has been engaged or involved as a contractor or material dealer or superintendent, or for which he or his employer has prepared plans or specifications, or in which he has any personal or financial interest. 107.6 Meetings. The Board shall meet within thirty (30) days after the filing of any appeal or request for action with the Secretary of the Board, and also periodically if the volume of its work so warrants. In Montgomery County the Secretary shall be responsible for scheduling meetings, notifying the Board Members of such meetings and for giving the required public notices for meetings. 107.7 Representation. Each appellant or applicant, the building official, and any other person whose interests may be affected by an appeal or application, shall be given a fair opportunity to be heard orally, in person or by counsel, and to present written evidence to the Board. 107.8 Application for Appeal or Action. Any person adversely affected may apply for an appeal from the decision of a building official refusing to grant a permit, or to permit the use of a particular material and/or equipment or method of construction in a proposed structure, provided such appeal is filed with the Board within thirty (30) days of date of receipt of the written decision from such building official. The appeal application must include pertinent information and payment of fees. The appeal shall be based on one or both of the following grounds, stated in the application, to wit: A. That the decision of the building official is erroneous or constitutes an erroneous application of the particular provisions of the code or related laws and ordinances involved or is otherwise contrary to law. B. That a modified application or alternative arrangement is available and feasible whereby the strict application of a particular provision or provisions may be modified with alternatives without defeating the public safety, health, and general welfare or the purpose of the code described in Section 102 above. Also see Section 326. A hearing shall be held within a reasonable time not to exceed thirty (30) days following receipt of the appeals application by the Secretary of the Board. The Board shall provide the appellant with written notice of its determination within thirty (30) days after the hearing. 107.8.1 Fee for Appeal or Action. In Montgomery County each application to that Board from an action of a building official shall be accompanied by fee of $100.00. Fees shall be deposited in accordance with applicable laws and shall be used to defray the normal expenses of the Board including the payment for the Secretary, payment for the preparation of transcript of hearings by a court reporter when deemed necessary, or such other similar expenses as the Board may authorize. The Secretary or the Board may provide for the presence of a court reporter at a hearing at the Secretary's discretion or at the discretion of the Board. The Appellant may require the presence of a court reporter at a hearing by giving notice to the Secretary to that effect at the time of filing the application for appeal. 107.8.2 Delegation of Test. In Montgomery County the building official shall, when he deems it desirable, request the Chairman to designate members of the Board to make an investigation into the facts and ramifications of an appeal and to make a report of findings to the Board. In this event, the decision of the Board may be postponed to a later date, within the discretion of the board, not to exceed sixty (60) days after the hearing at which such investigation was requested. 107.9 Quorum. A majority of the members of the Board shall constitute a quorum. A majority of the quorum shall be necessary to make a decision on an appeal, modification, deviation or an approved rule. 107.10 Re-hearing. The Board shall, upon application of either the appellant or the building official, grant re-hearing before the Board in any case where new evidence is presented which, in the opinion of the Chairman, may justify such re-hearing. Such re-hearing shall not serve to stop execution of the previous decision of the Board. SECTION 108 ALTERNATE MATERIALS AND SYSTEMS (Deleted - See Section 326) SECTION 109 MODIFICATIONS 109.1 Practical difficulties. When there are practical difficulties involved in carrying out the provisions of this code, the building official shall be permitted to grant modifications for individual cases. The building official shall first find that a special individual reason makes the strict letter of this code impractical and that the modification is in conformity with the intent and purpose of this code and that such modification does not lessen health, life safety and fire safety requirements. The details of actions granting modifications shall be recorded and entered in the office of the city's building official. SECTION 110 LIABILITY (Deleted) SECTION 111 PERMIT (Deleted) SECTION 112 PLANS 112.1 Plans required. When required by the building official, plans shall be drawn to scale and shall be of sufficient clarity to indicate the nature and extent of the work proposed and shall show in detail that it will conform to the provisions of this code and all relevant laws, ordinances, rules and regulations. Plans shall include a plot plan drawn to scale showing the location of all easements, drainage facilities, adjacent grades, property lines, the proposed building and of every existing building on the property. Plans shall also include the foundation plans, floor plans, all elevations, sections, structural elements and details to adequately describe the work and the location and use. The name, address, and telephone number of the person preparing the plans shall appear on the plans. The design loads shall be clearly indicated on the plans. 112.2 Plans on job required. When required by the building official, a copy of approved plans shall be kept on the site of the building or work at the time of inspection. SECTION 113 INSPECTION 113.1 Types of inspections. For on-site construction, from time to time the building official, upon notification from the permit holder or his agent, shall make or cause to be made any necessary inspections and shall either approve that portion of the construction as completed or shall notify the permit holder or his agent wherein the same fails to comply with this code. 113.1.1 Foundation inspection. Inspection of the foundation shall be made after poles or piers are set or trenches or basement areas are excavated and forms erected and any required reinforcing steel is in place and prior to the placing of concrete. The foundation inspection shall include excavations for thickened slabs intended for the support of load-bearing walls, partitions, structural supports, or equipment and special requirements for wood foundations. 113.1.2 Plumbing, mechanical and electrical inspection. Rough inspection of plumbing, mechanical and electrical systems shall be made prior to covering or concealment, before fixtures are set, and prior to framing inspection. 113.1.3 Frame and masonry inspection. Inspection of framing and masonry construction shall be made after the roof, masonry, all framing, fireblocking, draftstopping and bracing are in place and after the plumbing, mechanical and electrical rough inspections are approved. 113.1.4 Other inspections. In addition to the called inspections above, the building official shall be permitted to make or require any other inspections to ascertain compliance with this code and other laws enforced by the building official. 113.1.4.1 Fire-resistive construction inspection. Where fire-resistive construction is required between dwelling units or due to location on property, the building official shall require an inspection of such construction after all lathing and/or gypsum board is in place, but before any plaster is applied, or before gypsum board joints and fasteners are taped and finished. 113.1.5 Final inspection. Final inspection shall be made after the building is complete and ready for occupancy. 113.2 Occupancy Approval. Occupancy is prohibited prior to a final inspection and approval. 113.2.1 New buildings. A dwelling unit hereafter erected shall not be used or occupied in whole or in part until the certificate of occupancy has been issued by the building official. 113.2.2 Additions, alterations, accessory buildings. A dwelling unit hereafter added to or altered, and residential accessory buildings shall not be used or occupied, in whole or in part until a final inspection is approved, except that any use or occupancy which was not discontinued during the work of alteration shall require a final inspection and approval within 30 days of the completion of the alteration. 113.2.3 Temporary occupancy. Upon the request of the holder of a permit, the building official may issue a temporary certificate of occupancy for a building or structure, or part thereof, before the entire work covered by the permit shall have been completed, provided such portion or portions may be occupied safely prior to full completion of the building or structure without endangering life or public welfare. Temporary occupancy approval shall be valid for a time period determined by the building official. Using or occupying a structure after a temporary certificate of occupancy has expired, and without obtaining final occupancy approval, shall be a violation of this code. SECTION 114 PREFABRICATED CONSTRUCTION 114.1 General. A certificate of approval by an approved agency shall be furnished with every prefabricated assembly, except where all elements of the assembly are readily accessible to inspection at the site. Placement of prefabricated assemblies at the building site shall be inspected by the building official to determine compliance with this code, and a final inspection shall be provided in accordance with Section 113.1.5. NOTE: Provisions for foundation systems and building service equipment connections necessary to provide for the installation of new manufactured homes on privately owned (non-rental) lots and existing manufactured homes to which additions, alterations or repairs are made are contained in Appendix A and shall be enforced only when specifically adopted by the jurisdiction. SECTION 115 SWIMMING POOLS, SPAS AND HOT TUBS 115.1 General. The provisions of this Section shall apply to swimming pools, spas and hot tubs installed in or on the lot of a one, two and three family dwelling. 115.2 Definitions. For the purposes of these requirements, the terms used shall be defined as follows and as set forth in Chapter 2. Above-ground/on-ground pool. See "swimming pool." Barrier. A fence, wall, building wall or combination thereof which completely surrounds the swimming pool and obstructs access to the swimming pool. Hot tub. See "swimming pool." In-ground pool. See "swimming pool." Spa, nonportable. See "swimming pool." Spa, portable. A nonpermanent structure intended for recreational bathing, in which all controls, water-heating and water-circulating equipment are an integral part of the product. Swimming pool. Any structure intended for swimming or recreational bathing that contains water over 24 inches (610 mm) deep. This includes in-ground, above-ground and on-ground swimming pools, hot tubs and spas. Swimming pool, indoor. A swimming pool which is totally contained within a structure and surrounded on all four sides by walls of said structure. Swimming pool, outdoor. Any swimming pool which is not an indoor pool. 115.3 Barrier requirements. The provisions of this Section shall control the design of barriers for residential swimming pools, spas and hot tubs. These design controls are intended to provide protection against potential drownings and near-drownings by restricting access to swimming pools, spas and hot tubs. 115.4 Outdoor swimming pool. An outdoor swimming pool, including an in-ground, above-ground or on-ground pool, hot tub or spa, shall be provided with a barrier which shall comply with the following: 1. The top of the barrier shall be at least 48 inches (1219 mm) above grade measured on the side of the barrier which faces away from the swimming pool. The maximum vertical clearance between grade and the bottom of the barrier shall be 2 inches (51 mm) measured on the side of the barrier which faces away from the swimming pool. Where the top of the pool structure is above grade, such as an above-ground pool, the barrier shall be permitted to be at ground level, such as the pool structure, or mounted on top of the pool structure. Where the barrier is mounted on top of the pool structure, the maximum vertical clearance between the top of the pool structure and the bottom of the barrier shall be 4 inches (102 mm). 2. Openings in the barrier shall not allow passage of a 4 inch diameter (102 mm) sphere. 3. Solid barriers which do not have openings, such as a masonry or stone wall, shall not contain indentations or protrusions except for normal construction tolerances and tooled masonry joints. 4. Where the barrier is composed of horizontal and vertical members and the distance between the tops of the horizontal members is less than 45 inches (1143 mm), the horizontal members shall be located on the swimming pool side of the fence. Spacing between vertical members shall not exceed 1 3 / 4 inches (44 mm) in width. Where there are decorative cutouts within vertical members, spacing within the cutouts shall not exceed 1 3 / 4 inches (44 mm) in width. 5. Where the barrier is composed of horizontal and vertical members and the distance between the tops of the horizontal members is 45 inches (1143 mm) or more, spacing between vertical members shall not exceed 4 inches (102 mm). Where there are decorative cutouts within vertical members, spacing within the cutouts shall not exceed 1 3 / 4 inches (44 mm) in width. 6. Maximum mesh size for chain link fences shall be a 1 1 / 4 inches (32 mm) square unless the fence is provided with slats fastened at the top or the bottom which reduce the openings to not more than 1 3 / 4 inches (44 mm). 7. Where the barrier is composed of diagonal members, such as a lattice fence, the maximum opening formed by the diagonal members shall not be more than 1 3 / 4 inches (44 mm). 8. Access gates shall comply with the requirements of Items I through 7 of this Section, and shall be equipped to accommodate a locking device. Pedestrian access gates shall open outward away from the pool and shall be self-closing and have a self-latching device. Gates other than pedestrian access gates shall have a self-latching device. Where the release mechanism of the self-latching device is located less than 54 inches (1372 mm) from the bottom of the gate, the release mechanism and openings shall comply with the following: 8.1 The release mechanism shall be located on the pool side of the gate at least 3 inches (76 mm) below the top of the gate; and 8.2 The gate and barrier shall have no opening greater than 1 / 2 inch (12.7 mm) within 18 inches (457 mm) of the release mechanism. 9. Where an above-ground pool structure is used as a barrier or where the barrier is mounted on top of the pool structure, and the means of access is a ladder or steps, then: 9.1. The ladder or steps shall be capable of being secured, locked or removed to prevent access; or 9.2. The ladder or steps shall be surrounded by a barrier which meets the requirements of items 1 through 9 of this Section. When the ladder or steps are secured, locked or removed, any opening created shall not allow the passage of a 4 inch-diameter (102 mm) sphere. 115.5 Prohibited locations. Barriers shall be located so as to prohibit permanent structures, equipment or similar objects from being used to climb the barriers. 115.6 Barrier exceptions. A swimming pool with a power safety cover or a spa and hot tub with a safety cover that complies with ASTM F1346-91 shall be exempt from the provisions of this Section. SECTION 116 INSPECTION CARD 116.1 Record required. The permit holder or his agent shall post the inspection record on the job site in an accessible and conspicuous place to allow the building official to make the required entries. The record shall be maintained by the permit holder until the final inspection has been made and approved. SECTION 117 EXISTING STRUCTURES 117.1 Continuations of existing use. Buildings and structures in existence at the time of the adoption of this code shall be permitted to have their existing use continued if such use was legal at the time of adoption of this code, provided such continued use is not dangerous to life. 117.2 Additions, alterations or repairs. Additions, alterations or repairs to any structure shall conform to that required of a new structure without requiring the existing structure to comply with all of the requirements of this code, unless otherwise stated. Additions, alterations or repairs shall not cause an existing structure to become unsafe or adversely affect the performance of the building. Any building plus new additions shall not exceed the height in stories specified for new buildings in Section 103. 117.2.1 Structural and fire-resistance rated limits. Alterations or repairs to an existing structure which are structural or adversely affect any structural member or any part of the structure having a required fire-resistance rating shall be made with materials required for a new structure. 117.3 Unsafe buildings. Where a building is found to be a serious hazard, such hazard shall be eliminated or the building shall be vacated, and where such building, when vacated, remains a serious hazard, it shall be razed. Where the building official finds that a building is a serious hazard and the owner of such building fails, in the time specified in a written notice from the building official, to eliminate such hazard, or to vacate or raze the building, the building official shall proceed under Section 106.5 of this code and Section 3781.15 of the Ohio Revised Code. 117.4 Historic residential buildings, scope. The provisions of sections 117.4.1 and 117.4.2 shall apply to one, two and three family dwellings and their accessory structures located in historic districts shown on the official zoning map of the City of Dayton or listed on the local or National Register of Historic Places. 117.4.1 Compliance. Where the building official determines that plans for construction, repair, alteration and restoration of a dwelling or accessory structure are not in compliance with this code, the dwelling or accessory structure's owner may make a request for a waiver of compliance from the Technical Review Committee. The request shall be in writing on a form provided by the Department of Building Services. The owner shall specifically state the relief sought and the reasons for the request. The Technical Review Committee may grant a waiver where the majority of the Technical Review Committee determines that the planned construction, repair, alteration or restoration does not constitute a distinct life safety hazard. 117.4.2 Technical Review Committee. The Technical Review Committee shall consist of the Directors of the Department of Building Services, Planning and Community Development and Fire or their designees. SECTION 118 STOP WORK ORDERS 118.1 General. Upon notice from the building official, work on any building, structure, electrical, gas, mechanical or plumbing system that is being done contrary to the provisions of this code shall immediately cease. Such notice shall be in writing and shall be given to the owner of the property, or to his agent, or to the person doing the work, and shall state the specific violations and the conditions under which work shall be permitted to be resumed. The building official may post the notice on the job site. It shall not be obscured, defaced, or removed. Only the building official may remove it. Where an emergency exists, the building official shall not be required to give a written notice prior to stopping the work. SECTION 119 ENERGY CONSERVATION 119.1 General. Provisions for energy conservation are the same as those contained in the Ohio Building Code.

(Ord. 29119-95, passed 11-22-95; Am. Ord. 30111-02, passed 6-5-02)