§ 18-367 — Adoption of International Energy Conservation Code (2021); amendments
Code of Ordinances of Kansas City, Missouri (Supp. No. 140, Update 1: codified through Ordinance No. 260692, enacted August 13, 2026) · Kansas City Code § 18-367
Corpus is an independent public-information project, not the official City of Kansas City website. Stable reference: corpuslaw.us/code/c3af0cc7-e152-46df-86da-d39d449b989e
Sec. 18-367. - Adoption of International Energy Conservation Code (2021); amendments.
The International Energy Conservation Code (2021), promulgated by the International Code Council, is adopted and incorporated in this article by reference as if fully set forth, except as it is amended by the following provisions of this section. Provisions of this article are in addition to the provisions of the International Energy Conservation Code. The following provisions coinciding with provisions of the International Energy Conservation Code supersede, or delete, when indicated, the corresponding provisions of the International Energy Conservation Code. In addition, the IECC Appendix CC: Zero Energy Commercial Building Provisions is an option for builders to voluntarily implement. All references within the model codes to any building, electrical, gas, mechanical, plumbing, sewage disposal, elevator, energy conservation, or existing building code shall be construed to be a reference to the respective building, electrical, gas, mechanical, plumbing, sewage disposal, elevator, energy conservation, or existing building code specifically adopted by reference in articles II through XIV of this chapter. Chapter 1 [CE], SCOPE AND ADMINISTRATION is deleted. See article I of this chapter. C405.12 Electrical for future use on new buildings with electrical services 1. Provide 2-inch conduit run up to attic for future photovoltaic systems. 2. Provide 2-inch conduit run into parking areas for future electric vehicle charging stations. Chapter 1 [RE], SCOPE AND ADMINISTRATION is deleted. See article I of this chapter. Table R402.1.3 Amend zone 4 except marine wood frame wall R-value to R19. Table R402.4.1.1. Under 'Walls'. Amend first sentence to read: "Corners and headers shall be sealed and the junction of the foundation and sill plate shall be sealed." R403.3.5, Exception 2. Duct leakage testing is not required when all ductwork is located entirely within the building thermal envelope. R403.3.7, Exception. In IRC projects building framing cavities may be used as ducts or plenums where sealed to prevent leakage through the thermal envelope. R404.4 Electrical for future use on new buildings with electrical services. 1. Provide 2-inch conduit run up to attic for future photovoltaic systems. 2. Provide 2-inch conduit run into garage areas for future electric vehicle charging stations. R405.2 Amended as follows: Performance-based compliance. Compliance based on total building performance requires that a proposed design meets all of the following and has a HERS compliance score of 70 for single family residences under 2,000 square feet and a compliance value of 65 for residences over 2,000 square feet. Table R406.4 Amend Climate Zone 4 Energy Rating index to state the following: Energy Rating Index (ERI) compliance value of 70 for single family residences under 2,000 square feet and a compliance value of 65 for residences over 2,000 square feet.
(Ord. No. 040477, § 1, 8-12-04; Ord. No. 071193, § 1, 1-3-08; Ord. No. 120375, § 1, 5-24-12; Ord. No. 220364, § 2, 10-13-22; Ord. No. 260144, § 1, 2-5-26)
Ask a question about Kansas City law
Corpus searches the Kansas City sections it holds and shows the ones that match, with their citations. Free, no sign-in.
