§ 18.50.200 — FIRE SAFETY; EGRESS

City Code of Salt Lake City, Utah (2026 S-21: current through Ord. 49-26, passed September 15, 2026) · Salt Lake City Code § 18.50.200

Corpus is an independent public-information project, not the official City of Salt Lake City website. Stable reference: corpuslaw.us/code/c4193101-0a46-4668-8047-f18347f033bf

18.50.200: FIRE SAFETY; EGRESS:

A. Fire Safety: No hazard of fire or explosion shall be created or allowed to exist in any building, premises, equipment or apparatus. B. Exit and Emergency Egress: 1. Every existing dwelling unit shall have a safe, continuous and unobstructed means of egress of a minimum ceiling height of 6 feet 4 inches and a minimum egress width of 28 inches. Obstructions shall be allowed to 5 feet 10 inches when the obstruction is not in the pattern of circulation and obstructions are not greater than 20% of the floor area of the exitway. The exitway shall be kept in a proper state of repair and maintained free of hazardous conditions and obstructions. 2. Every sleeping room located below the fourth story shall have at least one openable window or exterior door approved for emergency egress or rescue. Every egress window shall comply with the construction codes adopted in Section 18.04.040, unless the size of the opening under such codes is not feasible then the opening shall have a minimum of 3 and 1/2 square feet of openable space and clear opening dimensions of at least 20 inches in one dimension and 24 inches in the other dimension. The escape window must open directly into a yard or exit court, or into a public street or alley. When windows are provided as a means of emergency egress or rescue, they shall have a finished sill height of not more than 48 inches. If the distance from the floor to the windowsill is more than 48 inches, a permanent ladder or platform attached to the wall or floor may be installed to meet the maximum height requirement. The ladder or platform must be approved by the city. 3. For windows that are below grade, a window well shall run parallel to the width of the window and extend at least 18 inches out from the exterior face of the building. When the distance from the top of the window well to its bottom exceeds 48 inches, it shall be equipped with an approved permanently affixed ladder or stairs that are accessible with the window in the fully open position. Grates are permitted over window wells when hinged away from the structure and not weighing over 15 pounds per section of the grate. 4. Bars, grills, grates or similar devices may be installed on emergency escapes or rescue windows or doors, provided such devices are equipped with approved release mechanisms which are operable from the inside of the grate without the use of a key or special knowledge or effort. C. Stairs and Handrails: Stairs and rails shall meet the requirements of the means of egress section of the applicable adopted state construction code with the following modifications: 1. If there are 4 or more risers, a handrail shall be required. Two handrails shall be required when the width of the stairs is 48 inches or more. Stairways less than 48 inches in width or stairways serving one individual dwelling unit in group R, division 1 or 3 occupancy, or a group R, division 3 congregate residence may have one handrail. Handrails are not required for monumental stairs. 2. Handrails shall be placed not less than 30 inches nor more than 38 inches above the outermost edge of the tread. Handrails for existing stairs are not required to extend beyond the top or bottom stair tread. 3. Stairs shall have a maximum riser height of 9 inches and a minimum step run of 8 inches. Existing stair flights may have a maximum variation in rise and run of 2 inches at the top and bottom of the flight. A maximum of 1 inch variation of rise and run shall be allowed for all intermediate risers and treads. Stairs shall be level and shall comply with life safety standards as defined herein. 4. Winding, circular and spiral stairs may run to narrow to a point. The run shall measure 8 inches (12 inches from the narrow point). 5. There shall be no minimum rise or run requirement nor maximum variation in the rise and run for stairs leading only to mechanical, storage, utility, and nonhabitable rooms in any residential structure and laundry rooms in individual dwelling units provided the stairs are structurally sound. 6. Steps shall be maintained in a safe manner. Missing steps, steps which are deteriorated to the point that a foothold is difficult to maintain, staircases which have missing boards, and/or staircases which contain boards that have lost their structural integrity shall be repaired to a safe condition. 7. Interior and exterior stairs shall have a minimum headroom height of 6 feet 4 inches so long as there are electrical powered smoke detectors installed pursuant to the construction codes adopted in Section 18.04.040, except for stairs to mechanical or storage rooms, utility and nonhabitable rooms in any residential structure and laundry rooms in individual dwelling units, which have no minimum headroom height. Within stairways obstructions shall be allowed to 5 feet 10 inches when the obstruction is not in the pattern of circulation and obstructions are not greater than 20% of the floor area of the stairway. 8. Stairs in the interior or exterior of an existing building where stair jacks are replaced or more than 50% of the tread or risers are replaced shall meet the requirements of the applicable adopted state construction code. 9. A stair tread, stair support, stair riser, landing or railing which is either missing or so severely in disrepair or damaged that it cannot support its intended live and dead loads shall be repaired. 10. Interior stair landings shall have a minimum width of 28 inches and a minimum length in the direction of travel of 30 inches. D. Guardrails: 1. Guardrails shall be required for all balconies, porches, patios and open stairs more than 30 inches above or below grade. Guardrails shall also be required for any grade change more than 30 inches next to a walking surface. Guardrails shall not be less than 42 inches in height, except for guardrails serving private dwelling units, which shall have a minimum height of 36 inches. Guardrails may have a minimum height of 36 inches if the building was built before 1970. Guardrails having a height less than 36 inches shall be allowed if they were installed as part of the building's original construction and are not a replacement. For structures which are on the historic register or are contributory structures located within one of the city's historic districts, height of existing and replacement guardrails may be determined based upon standards adopted by the city's historic landmark committee. 2. Guardrails shall have intermediate rails or an ornamental pattern such that there is no open area in excess of 4 inches in diameter. The diameter of such open space may be 9 inches for buildings built before 1985, and 6 inches for those built between 1985 and 1991. E. Smoke Detector Requirements: 1. When smoke detectors are required in dwelling units by the applicable adopted state construction code, the detectors shall be mounted on the ceiling or wall at a point centrally located in the hallway or area giving access to rooms used for sleeping. In efficiency dwelling units, the detector shall be centrally located on the ceiling or wall of the main room or sleeping room. 2. Where sleeping rooms are on an upper level, the detector shall be placed at the ceiling or wall directly above the stairway immediately outside the bedrooms. Wall mounted detectors shall be a minimum of 4 inches and maximum of 12 inches from the ceiling, but no detector shall be mounted within 12 inches of any corner formed by the meeting of walls, ceilings or beams unless manufacturer's listing specifies otherwise. When activated, the detector shall provide an alarm in the dwelling unit. 3. When one or more sleeping rooms are added to or created within a structure, smoke detectors shall be installed in compliance with the manufacturer's listing and shall receive their primary power from the building wiring in compliance with the applicable adopted state construction code. 4. All habitable rooms having a ceiling height of less than 7 feet 6 inches shall have installed a 120 volt electrical powered smoke detector. F. Fire Resistive Separations: Walls or ceilings separating dwelling units from each other and from hazardous uses shall be maintained in their original condition with all penetrations sealed or covered with an approved material. These separations include walls and ceilings separating a garage from a dwelling unit or common area and walls and ceilings separating furnace rooms in structures containing 3 or more dwelling units. When 50% or more of a wall or ceiling is removed for any reason, the entire wall or ceiling shall be reconstructed to meet the requirements of the applicable adopted state construction code for one hour occupancy separation. (Ord. 91-24, 2024: Ord. 74-98 §§ 15-22, 1998: Ord. 68-96 § 1, 1996: Ord. 55-95 § 4 (Exh. A), 1995)

Ask a question about Salt Lake City law

Corpus searches the Salt Lake City sections it holds and shows the ones that match, with their citations. Free, no sign-in.