Sec. 7-63. Minimum requirements for light and ventilation.

a. Size. Every habitable room shall have at least one (1) window or skylight facing directly to the outdoors. The minimum total window area, measured between stops, for every habitable room shall be eight (8) percent of the floor area of such room. Whenever walls or other portions of structures face window of any such room and such light-obstruction structures are located less than three (3) feet from the window and extend to a level above that of the ceiling of the room, such a window shall not be deemed to face directly to the outdoors and shall not be included as contributing to the required minimum total window area. Whenever the only window in a room is a skylight type window in the top of such room, the total window area of such skylight shall equal at least fifteen (15) percent of the total floor area of such room. b. Habitable rooms. 1. Every habitable room shall have at least one (1) window or skylight which can be easily opened, or such other device as will adequately ventilate the room. The total of openable window area in every habitable room shall be equal to at least forty-five (45) percent of the minimum window area size or minimum skylight type window size, as required, or shall have other approved, equivalent ventilation. 2. Year-round mechanically ventilating conditioned air systems may be substituted for windows, as required herein, in rooms other than rooms used for sleeping purposes. Window type air conditioning units are not included in this exception. c. Bathrooms. Every bathroom shall comply with the light and ventilation requirements for habitable rooms except that no window or skylight is required in adequately ventilated bathrooms equipped with an approved ventilating system. d. Electric lights and outlets required. Where there is electric service available to the building or structure, every habitable room or space shall contain at least two (2) separate and remote convenience outlets and bedrooms shall have, in addition, at least one (1) wall switch controlled ceiling or wall type light fixture. In kitchens, three (3) separate and remote convenience outlets shall be provided, and a wall or ceiling type fixture controlled by a wall switch shall be required. Every hall, water closet compartment, bathroom, laundry room or furnace room shall contain at least one (1) electric fixture. In bathrooms, the electric light fixture shall be controlled by a wall switch. In addition to the electric light fixture in every bathroom and laundry room, there shall be provided at least one (1) convenience outlet. Every such outlet and fixture shall be properly installed, maintained in good and safe working condition, and safely connected to the source of electric power. e. Light in public halls and stairways. Every common hall and inside stairway in every building, other than one-family dwellings, shall be adequately lighted at all times with an illumination of at least one (1) footcandle intensity at the floor in the darkest portion of the normally traveled stairs and passageways. (Ord. No. 0-97-61; 12/3/97) (Ord. No. 0-2000-27, 4-19-00)

Ask a question about Tyler law

Corpus searches the Tyler sections it holds and shows the ones that match, with their citations. Free, no sign-in.