15.36.040 - Noise level reduction standards—30 decibel.

Compliance with the following standards shall be deemed to meet requirements for a minimum noise level reduction of thirty (30) decibels. A. General. 1. Brick veneer, masonry blocks or stucco exterior walls shall be constructed airtight. All joints shall be grouted or caulked airtight. 2. At the penetration of exterior walls by pipes, ducts or conduits the space between the wall and pipes, ducts or conduits shall be caulked or filled with mortar. 3. Window and/or through-the-wall ventilation units shall not be used. 4. Operational-vented fireplaces shall not be used. 5. All sleeping spaces shall be provided with a carpeted floor. 6. Through-the-wall/door mailboxes shall not be used. B. Exterior walls. 1. Exterior walls, other than as described below, shall have a laboratory sound transmission class rating of at least STC-35. 2. Masonry walls having a surface weight of at least forty (40) pounds per square foot do not require a furred (stud) interior wall. At least one surface of concrete block walls shall be plastered. 3. Stud walls shall be at least four inches in nominal depth and shall be finished on the outside with siding-on-sheathing, stucco or brick veneer. a. Interior surfaces of the exterior walls shall be of gypsum board or plaster at least one-half-inch thick, installed on the studs. The gypsum board or plaster may be fastened rigidly to the studs if the exterior is brick veneer or stucco. If the exterior is siding-on-sheathing, the interior gypsum board or plaster must be fastened resiliently to the studs. b. Continuous composition board, plywood, plaster (stucco), or gypsum board sheathing at least three-quarter-inch thick shall cover the exterior side of the wall studs behind wood or metal siding. c. Sheathing panels shall be covered on the exterior with overlapping building paper. d. Insulation material at least R-11 shall be installed continuously throughout the cavity space behind the exterior sheathing and between wall studs. Insulation shall be glass fiber or mineral wool. C. Windows. 1. Windows, other than described in this section, shall have a laboratory sound transmission class rating of at least STC-33. 2. Glass of double-glazed windows shall be at least one-eighth-inch thick. Panes of glass shall be separated by a minimum one-half-inch airspace. 3. Double-glazed windows shall employ fixed sash or efficiently weather-stripped, operable sash. The sash shall be rigid and weather-stripped with material that is compressed airtight when the window is closed so as to conform to an infiltration test not to exceed 0.5 cubic foot per minute per foot of crack length in accordance with ASTM E-283-65-T. 4. Glass of fixed-sash windows shall be sealed in an airtight manner with a nonhardening sealant or a soft elastomer gasket or glazing tape. 5. The perimeter of window frames shall be sealed airtight to the exterior wall construction with a sealant conforming to one of the following federal specifications: TT-S-00227, TT-S-00230, or TT-S-00153. 6. Total area of glass shall not exceed twenty (20) percent of the total exterior wall area. D. Doors. 1. Doors, other than described in this section, shall have a laboratory sound transmission class rating of a least STC-33. 2. Double-door construction is required for all door openings to the exterior. Openings fitted with side-hinged doors shall have one solid-core wood or insulated hollow metal core door at least one and three-quarter-inch thick separated by an airspace of at least three inches from another door, which can be a storm door. Both doors shall be tightly fitted and weather-stripped. 3. The glass of double-glazed sliding doors shall be separated by a minimum one-half-inch airspace. Each sliding frame shall be provided with an efficiently airtight weather-stripping material as specified in subsection (C)(3). 4. Glass of all doors shall be at least three-sixteenth-inch thick. Glass of double sliding doors shall not be equal in thickness. 5. The perimeter of door frames shall be sealed airtight to the exterior wall construction as indicated in subsection (C)(5). 6. Glass of doors shall be set and sealed in an airtight nonhardening sealant or a soft elastomer gasket or glazing tape. E. Roofs. 1. Combined roof and ceiling construction, other than described in this section and subsection F, shall have a laboratory sound transmission class rating of at least STC-44. 2. With an attic or rafter space at least six inches deep, and with a ceiling below, the roof shall consist of three-quarter-inch composition board, plywood, or gypsum board sheathing topped by roofing as required. 3. Open beam roof construction shall follow the energy insulation standard method for batt insulation, except use one-inch plywood decking with shakes or other suitable roofing material in place of one-half-inch plywood. 4. Window or dome skylights shall have a laboratory sound transmission class rating of at least STC-33. F. Ceilings. 1. Gypsum board or plaster ceilings at least five-eighth-inch thick shall be provided where required by subsection (E)(2), above. Ceilings shall be substantially airtight, with a minimum number of penetrations. 2. Glass fiber or mineral wool insulation of at least R-19 shall be provided above the ceiling between joists. G. Floors. The floor of the lowest occupied rooms shall be slab on fill, below grade, or over a fully enclosed basement or crawl space. All door and window openings in the fully enclosed basement shall be tightly fitted. H. Ventilation. 1. A mechanical ventilation system shall be installed that will provide the minimum air circulation and fresh air supply requirements for various uses in occupied rooms without the need to open any windows, doors, or other openings to the exterior. The attic inlet and discharge openings shall be fitted with sheet metal transfer ducts of at least twenty (20) gauge steel, which shall be lined with one-inch thick coated glass fiber, and shall be at least five feet long with one ninety (90) degree bend. 2. Gravity vent openings in attics shall not exceed code minimum in number and size. The openings shall be fitted with transfer ducts at least three feet in length containing internal one-inch thick coated fiberglass sound-absorbing duct lining. Each duct shall have a lined ninety (90) degree bend in the duct such that there is no direct line-of-site from the exterior through the duct into the attic. 3. All vent ducts connecting the interior space to the outdoors, excepting domestic range exhaust and sewer gas ducts, shall contain at least a ten (10) foot length of internal sound-absorbing duct lining. Each duct shall be provided with a lined ninety (90) degree bend in the duct such that there is no direct line-of-sight through the duct from the venting cross-section to the room-opening cross-section. Duct lining shall be coated glass fiber duct liner at least one-inch thick. 4. Domestic range exhaust ducts connecting the interior space to the outdoors shall contain a self-closing baffle plate across the exterior termination which allows proper ventilation. The duct shall be provided with a ninety (90) degree bend or other mitigating measures approved by the building official.

(Ord. 1030 1 (part), 1991: prior code 13.90.040)

Ask a question about North Las Vegas law

Corpus searches the North Las Vegas sections it holds and shows the ones that match, with their citations. Free, no sign-in.