§ 214-35 — Delayed-Egress Locks

Milwaukee Code of Ordinances (Volumes 1-3 revised through Common Council action of Sept. 22, 2026) · Milwaukee Code of Ordinances § 214-35

Corpus is an independent public-information project, not the official City of Milwaukee website. Stable reference: corpuslaw.us/code/c8468e59-dcb2-4c25-af7b-f074e81eb546

214-35. Delayed-Egress Locks.

1. WHEN ALLOWED. In a building protected throughout by either a supervised automatic fire sprinkler system or a supervised automatic fire detection system, the exit doors may be equipped with listed, delayed-egress locking devices installed prior to July 1, 2002, provided the locking devices: a. Release or unlock upon activation of the sprinkler system or fire detection system. b. Release or unlock upon the loss of power to the locking devices. c. Release or unlock within 15 seconds whenever a force of not more than 15 pounds is continuously applied to the release device for a period of not more than 3 seconds. d. Upon the release or unlocking of the door, activate an audible alarm in the vicinity of the door. e. Require the manual re-locking of the doors. f. Have a sign adjacent to each locking device indicating how the door may be opened. 2. USE PROHIBITED OR RESTRICTED. Delayed locking devices shall not be used on any doors of a community-based residential facility, as defined in s. 295-201-113-b, or doors serving as the main entrance and exit of an assembly hall with a legal capacity exceeding 99 persons. Not more than one locking device may be used in any egress path within a health care center, including a hospital or nursing home. the Municipal Research Library. (Pages 81-90 are blank.)

Ask a question about Milwaukee law

Corpus searches the Milwaukee sections it holds and shows the ones that match, with their citations. Free, no sign-in.