§ 49-610 — Floor drains
Omaha Municipal Code (Supp. No. 100, Update 2: codified through Ordinance No. 44760, enacted August 4, 2026) · Omaha Municipal Code § 49-610
Corpus is an independent public-information project, not the official City of Omaha website. Stable reference: corpuslaw.us/code/c88be028-c446-4501-853a-35d9513d4729
Sec. 49-610. - Floor drains.
The following provisions shall be followed: (a) Shall conform to ASME/ANSI A1 12.21.1M and CISPI C74-837 and shall not have an integral cleanout. (b) Shall have removable strainers with a minimum width of five inches. The area of the openings in the strainer shall be equal to the area of the waste pipe serving the drain. (c) All trap construction shall allow for drain cleaning. (d) Shall have a two inch minimum diameter waste. (e) When installed in floors above the basement floor shall be provided with a pan which shall extend a minimum of one foot beyond the outer edge of the trap. Weep holes from the pan shall discharge into the waste line on the strainer side of trap. Exception: Drains in single-family dwellings and drains installed in post tension concrete slabs shall not require a pan. (f) Drains designed to meet special needs may be approved by the plumbing board.
(Ord. No. 40524, § 1, 10-20-15)
Ask a question about Omaha law
Corpus searches the Omaha sections it holds and shows the ones that match, with their citations. Free, no sign-in.