§ 15-2610 — STANDARDS FOR SPECIFIC SIGN TYPES
Fresno Municipal Code (Supp. No. 55, Update 1 (online June 23, 2026): codified through Ordinance No. 2026-019) · Fresno Municipal Code § 15-2610
Corpus is an independent public-information project, not the official City of Fresno website. Stable reference: corpuslaw.us/code/c9116e2c-8d88-4a95-bebf-693b2921507b
SEC. 15-2610. - STANDARDS FOR SPECIFIC SIGN TYPES.
This section establishes location and other general standards for specific sign types that apply to all areas where such signs are permitted. Additional standards applicable to these signs in specific zoning districts or associated with specific uses are located in Sections 15-2608, Standards for Signs by District, and 15-2609, Signage Allowances for Specific Uses. A. Awning and Canopy Signs. Signs painted or printed on awnings, mounted to canopies, or similar features or structures are subject to the following standards: 1. Location. Awnings/canopies that display signage shall be located on the ground floor of buildings. 2. Maximum Sign Area Per Sign. 10 square feet or 25 percent of the surface area of the awning, whichever is less. Signs mounted to canopies shall be no taller than 24 inches. 3. Minimum Sign Clearance. Eight feet. 4. Illumination. Internal illumination of awnings is prohibited. [image omitted; see the official code] FIGURE 15-2610-A: AWNING SIGN [image omitted; see the official code] FIGURE 15-2610-B: CANOPY SIGN B. Pole Signs. Pole signs are subject to the following standards: 1. Maximum Number. One per 600 feet of street frontage. 2. Maximum Sign Area per Sign. The sign area shall not exceed 80 square feet. In cases in which a pole sign of more than 20 feet in height is permitted per the table in subsection B-4 below, the maximum sign area shall be determined at the discretion of the Review Authority. 3. Minimum Separation. Pole signs shall have a minimum separation of 75 feet from any other pole sign. 4. Required Setback. Signs shall be setback back a minimum of ten feet from the property line. No pole sign is permitted within 660 feet of the nearest edge of any travel lane of Freeway 41, Freeway 180, Freeway 168, or any future freeway which may be opened to public travel, if any said sign is visible from any part of such travel lane. 5. Maximum Height. Maximum height of pole signs shall be based on the gross floor area of the habitable, enclosed, non-residential structures on the subject parcel and the classification of the adjacent or nearest street as follows: Gross square footage | Classification of Street Freeway | Expressway | Arterial | Collector/Other 300,000 or more | 90 feet | 80 feet | 75 feet | 50 feet 100,000 to 299,999 | 60 feet | 50 feet | 40 feet | 25 feet Less than 100,000 | 40 feet | 30 feet | 20 feet | 20 feet 6. Minimum Sign Clearance. Eight feet. 7. Landscaping Required. All pole signs shall require landscaping at the base equivalent to two times the area of the sign copy. 8. Lighting. Lighting systems shall not exceed 100 foot Lamberts (FT-L) when adjacent to streets which have an average light intensity of less than 2.0 horizontal foot candles. When adjacent to streets with a greater average light intensity, systems shall not exceed 500 FT-L. C. Monument Signs. Monument signs are subject to the following standards: 1. Maximum Number. One per 600 feet of street frontage. 2. Maximum Sign Area per Sign. a. RMX, CR, CG, CH, and RBP districts: 60 square feet. b. Other permitted districts: 32 square feet. 3. Minimum Separation. Monument signs shall have a minimum separation of 50 feet from any other monument sign. 4. Required Setback. a. Five feet from the property line. b. No monument sign is permitted within 660 feet of the nearest edge of any travel lane of Freeway 41 or any future freeway which may be opened to public travel, if any said sign is visible from any part of such travel lane. 5. Height Limit. Eight feet. a. Exception. When permitted within a Downtown (DT) District: five feet. 6. Lighting. Lighting systems shall not exceed 100 foot Lamberts (FT-L) when adjacent to streets which have an average light intensity of less than 2.0 horizontal foot candles. When adjacent to streets with a greater average light intensity, systems shall not exceed 500 FT-L. D. Projecting Signs. Signs under canopies or covers in conjunction with pedestrian walkways, or signs projecting from buildings are allowed, subject to the following additional standards: 1. Maximum Number. One per or tenant space per frontage. 2. Maximum Sign Area Per Sign. a. Projecting Signs. i. DT Districts: 150 square feet. ii. MX and CMS Districts: 50 square feet. iii. All Other Districts: 12 square feet. b. Under Canopy or Awning Signs. Eight square feet. 3. Height Limit. a. DT, MX, and CMS Districts: 10 feet above roof. b. All Other Districts: 12 feet above finished grade. 4. Minimum Sign Clearance. Eight feet. 5. Projection Allowed. A projecting sign cannot extend more than four feet from the building to which it is attached and shall be designed and located so as to cause no harm to street trees. 6. Illumination. Within DT, MX, and CMS Districts. If illuminated, Projecting Signs may be only illuminated by one of the following methods: a. External Illumination. Externally illuminated with decorative lamps mounted in a manner that does not block the view of the sign from the street or sidewalk. b. Exposed Neon. Individual letters may be internally illuminated with exposed neon tubes or a similar light source, but shall not have a translucent panel, lens, or face. c. Halo. The illumination of a sign by projecting light behind an opaque letter or emblem which results in the appearance of ring of light around the unilluminated letter or emblem. [image omitted; see the official code] FIGURE 15-2610-D: PROJECTING SIGNS E. Wall Signs. Wall signs are subject to the following standards: 1. Maximum Number. One per building frontage or tenant space plus one building identification sign per building frontage located on the uppermost story of a building with four or more stories. 2. Maximum Sign Area Per Sign. 10 percent of the wall area. 3. Height Limit. The top of Wall Signs shall be no higher than the following: a. Downtown Districts. Wall Signs shall not be located closer than 12 inches to the eve or parapet. b. Other Districts, Buildings Which Include Residential Uses. 20 feet or the height of the wall of the building to which the sign is attached, whichever is lower. Building identification signs located on the uppermost story of a building shall be no higher than the wall of the building to which the sign is attached. c. Other Districts, Buildings Which Do Not Include Residential Uses. The height of the wall of the building to which the sign is attached. 4. Projection Allowed. Wall signs shall not extend more than 12 inches beyond the face of the wall to which they are attached. 5. Placement. a. No wall sign may cover, wholly or partially, any wall opening. b. Wall signs shall not occupy more than 80 percent of any architectural element that they occupy (frieze, pilaster, etc.). c. Buildings within Downtown Districts. Wall Signs shall not be located closer than 24 inches from openings or the edge of the building façade. 6. Orientation. Unless a different orientation is specifically authorized, each wall-mounted sign shall be placed flat against the wall of the building. 7. Illumination within DT and CMS Districts. If illuminated, Wall Signs may be only illuminated by one of the following methods: a. External Illumination. Externally illuminated with decorative lamps mounted in a manner that does not block the view of the sign from the street or sidewalk. b. Exposed Neon. Individual letters may be internally illuminated with exposed neon tubes or a similar light source, but shall not have a translucent panel, lens, or face. c. Halo. The illumination of a sign by projecting light behind an opaque letter or emblem which results in the appearance of ring of light around the unilluminated letter or emblem. [image omitted; see the official code] FIGURE 15-2610-E: WALL SIGN F. Window Signs. Window signs are subject to the following standards: 1. Maximum Number. One per window. 2. Location. Ground floor window area. 3. Window Transparency. A minimum 75 percent of the window shall be transparent and free of signage features. Signage inside the building is not allowed within three feet of the window. G. Roof Signs. Roof signs are subject to the following standards: 1. Maximum Number. One per building. 2. Maximum Sign Area Per Sign. a. Buildings Less than Five Stories in Height. 300 square feet. b. Buildings Five Stories in Height or Taller. 500 square feet. 3. Maximum Height. a. Buildings Less than Five Stories in Height. 10 feet. b. Buildings Five Stories in Height or Taller. 20 feet. 4. Projection Allowed. Roof signs shall not project beyond the face of the building. 5. Placement. No roof sign may cover, wholly or partially, any wall opening. 6. Illumination. If illuminated, Roof Signs may be only illuminated by one of the following methods: a. External Illumination. Externally illuminated with concealed flood lighting. b. Exposed Neon. Individual letters may be internally illuminated with exposed neon tubes or a similar light source, but shall not have a translucent panel, lens, or face. c. Halo. The illumination of a sign by projecting light behind an opaque letter or emblem which results in the appearance of ring of light around the unilluminated letter or emblem.
(Added Ord. 2015-39, § 1, eff. 1-9-16; Am. Ord. 2016-32, § 23, eff. 10-21-16; Am. Ord. 2016-43, §§ 10—12, eff. 12-9-16; Am. Ord. 2017-33, § 21, eff. 7-30-17; Am. Ord. 2018-25, §§ 22—24, eff. 6-11-18).
Ask a question about Fresno law
Corpus searches the Fresno sections it holds and shows the ones that match, with their citations. Free, no sign-in.
