18.49.050 - Amend CEBC Section 506.5.3—Seismic loads.

Section 506.5.3 of the California Existing Building Code is amended to read as follows: 506.5.3 Seismic loads (seismic force-resisting system). Where a change of occupancy results in a building being assigned to a higher risk category, the change is from a Group S or Group U occupancy to any occupancy other than Group S or Group U, or the change is to Groups A, E or I occupancies in a building or structure constructed prior to January 9, 1934 and is within the scope of Chapter 18.68 of the Long Beach Municipal Code, the lateral force-resisting system of the building shall comply with Section 304.3.1 for the risk category assigned to the changed occupancy. Where a change of occupancy results in a building being assigned to Risk Category IV and Seismic Design Category D or F, nonstructural components serving any portion of the building changed to Risk Category IV shall comply with the requirements of Section 1613 of the California Building Code or shall comply with ASCE 41 using an objective of Operational nonstructural performance with the BSE-1N earthquake hazard level. Exceptions: 1. Where the area of the new occupancy is less than 10 percent of the building area, the occupancy is not changing from Group S or Group U occupancy, and the new occupancy is not assigned to Risk Category IV, compliance with this section is not required. The cumulative effect of occupancy changes over time shall be considered. 2. Where a change of use results in a building or structure being reclassified from Risk Category I or II to Risk Category III and the seismic coefficient, S DS , is less than 0.33, compliance with this section is not required. 3. Unreinforced masonry bearing wall buildings assigned to Risk Category III and to Seismic Design Category A or B, shall be permitted to use Chapter 18.68 of the Long Beach Municipal Code. 4. Where the change is from Group S or Group U occupancy and there is no change of risk category, compliance with Section 304.3.2 shall be permitted. For a change of occupancy from an existing commercial or industrial use to a residential use that does not result in a higher risk category, refer to Section 503 and Chapter 18.63 of the Long Beach Municipal Code for Alternative Building Standards for Adaptive Reuse Projects.

(ORD-25-0019 § 1(Exh. A), 2025; ORD-22-0033 § 1(Exh. A), 2022; ORD-19-0031 § 1(Exh. A), 2019)

Ask a question about Long Beach law

Corpus searches the Long Beach sections it holds and shows the ones that match, with their citations. Free, no sign-in.