Adjacent channel power limits.
47 C.F.R. § 90.221
in effect(a) For the frequency bands indicated below, operations using equipment designed to operate with a 25 kHz channel bandwidth may be authorized up to a 22 kHz bandwidth if the equipment meets the adjacent channel power (ACP) limits below. The table specifies a value for the ACP as a function of the displacement from the channel center frequency and a measurement bandwidth of 18 kHz.
(b)(1) Maximum adjacent power levels for frequencies in the 450-470 MHz band:
Frequency offset
Maximum ACP (dBc) for devices 1 watt and less
Maximum ACP (dBc) for devices above 1 watt
25 kHz−55 dBc−60 dBc
50 kHz−70 dBc−70 dBc
75 kHz−70 dBc−70 dBc
(2) In any case, no requirement in excess of −36 dBm shall apply.
(c)(1) Maximum adjacent power levels for frequencies in the 809-824/854-869 MHz band:
Frequency offset
Maximum ACP (dBc) for devices less than 15 watts
Maximum ACP (dBc) for devices 15 watts and above
25 kHz−55 dBc−55 dBc
50 kHz−65 dBc−65 dBc
75 kHz−65 dBc−70 dBc
(2) In any case, no requirement in excess of −36 dBm shall apply.
(d) On any frequency removed from the assigned frequency by more than 75 kHz, the attenuation of any emission must be at least 43 + 10 log (Pwatts) dB.
Source: eCFRURL: https://www.ecfr.gov/api/versioner/v1/full/2024-07-01/title-47.xmlFetched: 7/26/2026