§ 34-1077 — Inspection and testing
San Antonio City Code (Supp. No. 147: codified through Ordinance No. 2026-09-10-547, adopted Sept. 10, 2026) · San Antonio City Code § 34-1077
Corpus is an independent public-information project, not the official City of San Antonio website. Stable reference: corpuslaw.us/code/c957ed27-37d5-47c2-916f-4be3651c713e
Sec. 34-1077. - Inspection and testing.
(a) Each customer is responsible for the maintenance and repair of each backflow prevention assembly that is located on the customer's property. (b) Each customer shall have each backflow prevention assembly located on a customer's property inspected and tested annually by a BPAT and shall also be tested immediately after installation, relocation, repair or work performed upstream of the assembly. However, more frequent testing may be required if notice is provided by the SAWS to the customer. The BPAT performing the inspection and testing shall complete a report of each inspection and testing on a form approved by the public water system that provides water to the property where the backflow prevention assembly is located. (c) Each customer shall repair or replace a backflow prevention assembly that fails a test before returning the backflow prevention assembly to service. If an assembly fails a backflow prevention assembly test, the BPAT tester shall immediately notify the customer and submit a failed backflow T&M report to the system, via the approved submission process. The assembly shall be replaced or repaired within the period set by SAWS or within five (5) calendar days from the date of assembly failure whichever date is sooner. In the event of assembly failure, water service shall not be connected or restored until the assembly has been repaired or replaced and passes a retest unless written authorization is given by SAWS that water service is authorized to be connected or restored at an earlier date. (d) Each customer or the customer's representative shall deliver the annual T&M report that is required to be performed by this section to the designated backflow program administrator for the public water system that provides water to the property where the backflow prevention assembly is located before the end of the designated month assigned by SAWS, based on the last T&M report submitted to SAWS. If a T&M report has not previously been submitted, SAWS will assign submission months throughout a twelve-month cycle. (e) A T&M report must be completed by a BPAT for each assembly tested. The signed and dated form must be submitted to the public water system that provides water to the property where the backflow prevention assembly is located within ten (10) days after the completed test. Only SAWS or an approved TCEQ backflow prevention assembly test and maintenance forms will be accepted. T&M reports must be submitted in the format designated by SAWS. The submission of the T&M forms may include the submission through a designated backflow program administrator. SAWS or its designated backflow program administrator will determine how the T&M forms submission shall be done, which includes but is not limited to electronic submission. All TCEQ requirements for submission must be followed by the T&M submitter. All test and maintenance reports shall be retained by the owner of the property where the backflow prevention assembly is located for at least three (3) years after the date of any such test.
(Ord. No. 2011-06-23-0575, § 2, 6-23-11; Ord. No. 2019-02-14-0123, § 1(Att. I), 2-14-19; Ord. No. 2024-11-07-0875, § 1(Exh. A), 11-7-24)
Ask a question about San Antonio law
Corpus searches the San Antonio sections it holds and shows the ones that match, with their citations. Free, no sign-in.
