For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17.50.350 — Urban Housing

Pasadena Municipal Code, California (Supp. No. 79: codified through Ordinance No. 7469, enacted May 18, 2026) · Pasadena Municipal Code § 17.50.350

Corpus is an independent public-information project, not the official City of Pasadena website. Stable reference: corpuslaw.us/code/cb143a35-1df6-4eb6-a2e8-91fc43b81487

17.50.350 - Urban Housing

A. Applicability. The development standards of this Section shall apply to multi-family residential development projects utilizing a density greater than 48 dwelling units per acre located outside of a Residential zoning district or Specific Plan area. B. Density and height standards. The density and height standards for an urban housing development project shall be in compliance with the underlying zoning district. C. Setbacks required. In order to provide suitable amounts of air, light, and open space, the following setbacks shall be required: 1. Front and corner side: In compliance with the underlying zoning district. 2. Side and rear: a. Ten-foot minimum. b. Through the Design Review process, the side and rear setbacks may be reduced if the reduction results in a larger courtyard. D. Street entries required. Residential dwelling units located adjacent to the street shall have direct entries from the street. E. Open space required: 1. A minimum of 30 percent of the net floor area of the structure shall be provided as open space. 2. The minimum dimension of any open space shall be six feet in any direction. Private balconies, at-grade patios, rooftop gardens (including upper level terraces), and the portion of a front or corner side yard setback that is greater than the minimum requirement may be counted as open space. 3. Not more than 35 percent of the total open space may be met by counting balconies. 4. Planter balconies that are two feet or less in width shall not be counted as open space. F. Courtyard requirement. There shall be a ground-floor landscaped courtyard that shall be a minimum of 20 feet in any direction. Balconies may project up to four feet into the courtyard. G. Courtyard opening required. 1. Opening required. For structures with 75 feet of street frontage or more, the street side of the structure shall have an opening into a landscaped courtyard. 2. Minimum height of opening. This opening shall be a minimum of 50 percent of the overall height of the structure but not more than 25 feet. 3. Minimum width of opening. a. The width of the opening shall be a minimum of 10 feet. b. If the depth of the structure opening is more than 30 feet, the minimum width of the opening shall be increased by one foot for every three feet of depth above 30 feet. 4. Multiple frontages. For structures with multiple frontages, the Design Review process shall determine which frontages shall have an opening in compliance with Section 17.61.030. 5. Gate transparency. Any gate placed across the courtyard opening shall have a minimum of 75 percent transparency. 6. Modification through Design Review. The requirements of this Subsection may be modified through the Design Review process. H. Parking and Driveways. 1. Location of parking. a. Parking areas shall be provided either at grade, semi-subterranean, or subterranean. b. Parking areas (e.g., provided at grade or semi-subterranean) shall not abut the front or corner side street elevations. Only completely subterranean parking facilities may be located within the front or corner side setbacks. All other parking areas shall be located behind the habitable living space required by Subparagraph c., immediately below. c. Each dwelling unit contiguous to a front or corner side street elevation shall have a habitable living space on the ground floor that is a minimum of 12 feet in depth, measured from the interior wall closest to the street. 2. One space per unit on-site. For new development projects, parking shall be provided in compliance with Table 4-5 (Off-Street Parking Space Requirements — multi-family dwelling units) and there shall be a minimum of one off-street parking space for each residential unit located on the subject site. 3. Guest parking required. Guest parking shall be provided for the residential units in compliance with Table 4-5 (Off-Street Parking Space Requirements — multi-family dwelling units). 4. Other spaces may be located off-site. All other parking spaces designed to serve the residential units may be located off-site with a long-term parking lease agreement in compliance with Subsection 17.46.020 I. (Location and ownership). 5. Distance requirements. Off-site parking for residential units shall meet the distance requirements for commercial customer/visitor spaces in compliance with Subsection 17.46.020.I (Location and ownership). 6. Conversion of existing structures. Conversions of existing structures (including additions) may provide parking for residential units off-site as long as they meet the distance requirements and there is a long term parking lease agreement all in compliance with Subsection 17.46.020 I.(Location and ownership). 7. Driveway location. Driveways shall be located not more than five feet from a side property line. The review authority (i.e., Design Commission, Planning Director) may modify the location of a driveway to preserve a street tree or tree located on the site. I. Landscaping required. All areas of the subject site not devoted to lot coverage, driveways, or walkways shall be properly landscaped and maintained in compliance with Chapter 17.44 (Landscaping). J. Balconies. 1. Balconies may project no closer than six feet to an interior or rear property line and four feet into a front or corner side setback. 2. Balconies shall have a minimum dimension of six feet in order to count as required open space. 3. Balconies that are designed to project over the public right-of-way shall have prior approval from the Department of Public Works. K. Fences and walls. 1. Fences and walls located along a street frontage are limited to four feet in height. 2. Fences and walls located within rear and interior side setbacks are limited to six feet in height. 3. Projects with rear and interior side yards located adjacent to commercial uses may have a fence or wall height up to eight feet. 4. Fences located within front and corner side setbacks shall have a minimum of 50 percent transparency. 5. Fence height shall be measure from the existing grade. L. Overnight parking permits not allowed. 1. Up to one overnight street permit may be issued for each approved off-street parking space converted to an accessory dwelling unit or junior accessory dwelling unit in compliance with Section 17.50.275. In all other instances, City Permits for overnight parking on City streets shall not be issued for residential development projects built in compliance with this Section. 2. Residential tenants shall be advised of the unavailability of on-street overnight parking permits. M. Urban noise levels. 1. Residents of an urban housing development project shall be notified that they are living in an urban area and that the noise levels may be higher than in a typical residential area. 2. The signature of the residents shall confirm receipt and understanding of this information. N. Loading and unloading of household goods. If the loading and unloading of furniture and household goods for residential dwelling units is to occur on the street, it shall be limited to the hours of 9:00 a.m. to 2:00 p.m. and 7:00 p.m. to 10:00 p.m. on weekdays and 9:00 a.m. to 10:00 p.m. on weekends.

(Ord. No. 7435, § 18, 10-28-2024; Ord. No. 7420, § 7, 4-15-2024; Ord. No. 7419, § 4, 2-26-2024; Ord. No. 7388, § 2(Exh. 1), 3-21-2022)

Ask a question about Pasadena law

Corpus searches the Pasadena sections it holds and shows the ones that match, with their citations. Free, no sign-in.