236-11. Spray Coating.
1. SCOPE AND PURPOSE. a. Scope. These rules shall govern the use and control of all spray coating apparatus, in every place of employment; provided, however, that they shall not prohibit any farmer, horticulturist, fruit grower or other person engaged in farming or fruit or vegetable growing from using spray coating apparatus for the purpose of spraying trees, shrubs and vines with chemicals to protect the same from disease; or prohibit any dairyman, creamery owner or operator or other person from using any spray coating apparatus to spray any building or part thereof with solutions composed of water and chemicals of recognized value in keeping said building in a sanitary condition. b. Existing Booths. These rules are not applicable to existing installations except where adequate protection to the health and safety of the operator or helper requires alterations. All such alterations shall show reasonably close adherence to the provisions of these rules. c. Plans, Booth Installations. Plans and specifications in duplicate shall be submitted to the commissioner of city development for approval before installing any spray booth. 2. DEFINITIONS. a. Apparatus, Spray Coating. Any and all devices used in the application of finishing materials by a method employing air pressure. b. Approved. Of such design and arrangement as to meet the approval of the commissioner. c. Booths: Cabinet, Canopy, Room and Tunnel. c-1. Cabinet booth. An enclosure open on one side only and equipped with independent exhaust system. c-2. Canopy Booth. An overhead dome enclosure open on all sides at the bottom and equipped with an independent exhaust system. c-3. Room Booth. A room or enclosure equipped with independent exhaust system. c-4. Tunnel Booth. An enclosure with both ends open, equipped with independent exhaust system. d. Breathing Zone. The immediate area around the mouth and nose of the operator while in a working position. e. Contaminated Airway. A contaminated airway in connection with any type of spray booth is any duct, chamber or space containing vapors or fumes of a deleterious, flammable or explosive character, or of other harmful nature, generated by spray coating operations. f. Discharge Orifice. An opening through which ventilating air is discharged from a booth. g. Discharge Pipe. An extension of the discharge orifice to convey spray-laden or contaminated air to the outside atmosphere. h. Distributor Plates. Solid or perforated noncombustible plates placed in a booth to deflect and distribute air currents. i. Exhaust System. All equipment connected with the removal of ventilating air from the spray zone. j. Incombustible Material. Material which cannot be burned. k. Installations, Existing and New. k-1. Existing installations. Installations in existence and use prior to the effective date of this code. k-2. New installations. Installations completed, or the contracts for which are let after the effective date of these rules. L. Lamps, Extension, Portable, Explosion-proof and Vapor-proof. L-1. Extension lamp. Lamp or extension cord not fixed, nor self-supporting, and not equipped with standard. L-2. Portable, explosion-proof lamp. A portable explosion-proof lamp is a lamp not fixed, but with self-supporting, properly weighted stand, capable of being readily moved and having the lighting unit so designed and constructed that its use to provide artificial illumination at different points within any type of spray booth will not ignite any fumes, vapors or residues formed in the process of coating objects with a spray gun. L-3. Vapor-proof or vapor-tight lamp. A lamp that is so enclosed that vapor will not enter the enclosure. m. Orifice Outlet. See Discharge orifice. n. Place of Employment. For purposes of administering this code, a place of employment is any place where spray coating is being carried on for profit. o. Pressure, Atomizing and Paint. o-1. Atomizing pressure. Pressure of the air used to atomize or break up the paint or other coating material. o-2. Paint pressure. Pressure in a closed tank bearing on the paint or other coating material to raise it to the spray gun level. p. Pressure Regulator. An instrument or device for regulating or controlling air pressure. q. Pressure Tank. A tank in which air pressure is used to develop pressure on paint or other coating material. r. Respirators, Air Line and Chemical Cartridge. r-1. Air line respirator. A device consisting of a hood or head and face covering to which fresh air is fed, creating a slight outward pressure excluding fumes and mist, thus permitting breathing of uncontaminated air. r-2. Chemical cartridge respirator. A respirator which is equipped with a chemical cartridge which mechanically removes solid particles and chemically removes vapors from air being breathed. s. Settling Chamber. A space located in the exhaust air stream for the purpose of collecting solids in spray mist. t. Spray Gun. A mechanical device employing air pressure for the application of paints, varnishes, lacquers and similar finishing materials. u. Vacuum Type Feed Cup. (Sometimes erroneously referred to as a siphon type.) A type of materials container in which the liquid is drawn into the atomizing air stream by a partial vacuum created by the flow of air over the paint chamber outlet opening. v. Ventilating System. See Exhaust system. 3. SPRAY COATING OF BUILDINGS, STRUCTURES, AND OUTDOOR SPRAYING. a. Scope. The requirements of this section shall apply to all spray coating operations on buildings, ships and structures of any kind or nature, and to all outdoor spray coating operations, but these requirements need not apply to spray coating operations in approved booths. b. Equipment. b-1. Type of Equipment. Any type of equipment may be used, except the vacuum type of more than one quart capacity. Note: The vacuum type of spray coating apparatus is sometimes erroneously referred to as siphon type, suction type and ejector type. b-2. Character of Equipment. All spraying equipment shall be complete in all details essential to effective operating and prevention of excessive mist. c. Operation. c-1. Nozzle Distance from Surface. During operation the nozzle of the spray gun shall not at any time be more than 13 inches from the surface being spray coated. c-2. Scaffolding. When necessary, scaffolding or other approved support shall be used so that the maximum allowable distance between the gun nozzle and surface being spray coated will not be exceeded. c-3. Maximum Allowable Paint Pressure. The paint pressure shall at no time exceed that necessary to produce a free flow of paint at the nozzle when the gun is operated independent of atomizing pressure. Note a. Testimony of spray gun manufacturers and observations have shown that excessive paint pressure over that actually necessary to produce this result requires a correspondingly higher atomizing pressure, resulting in excessive mist. Note b. Exterior painting-wind advantage. During exterior spray coating, the operator shall at all times take advantage of draft and wind conditions, spraying with the air current whenever possible. Note c. Interior painting-natural ventilation. During interior spray coating of walls or structural members of a building the operator should at all times produce and maintain all ventilation possible by opening doors and windows, spraying with the air current whenever possible. c-4. Operation at Different Levels. At no time shall 2 or more operators working at elevations differing more than 8 feet use paint from the same supply tank unless spray guns are equipped with paint pressure regulators. Note: If this maximum allowable difference in working elevations were exceeded, the operators working at the lower levels would be subjected to excessive mist. c-5. Exclusion of Others. None other than the paint sprayers and their helpers shall be permitted within a zone where a mist or deposit is apparent, unless such a person is protected the same as operators and helpers. c-6. Contamination of Adjacent Areas. Proper precautionary measures shall be taken to prevent contamination of the atmosphere in adjacent occupied areas. 4. SPRAY COATING OPERATIONS INSIDE OF BUILDING. a. Scope. The requirements of this section shall apply to all spray coating of walls, structural members and fixtures of a building or other structure. b. Booths Required. Spray coating of objects with paint, varnish, lacquer, siliceous materials or other materials which may endanger the health of a person exposed thereto, or which would create a fire or explosion hazard, shall be carried on only in suitable booths provided and maintained for such purposes. Whenever practicable, a cabinet booth shall be used. A tunnel booth, canopy booth or a room booth may be used only with the written permission of the commissioner. Exception No. 1: Large objects such as heavy machinery, large castings and structural members not adaptable to booth spraying may be sprayed without booth protection provided that in such cases the requirements in sub. 3 are complied with and provided further, that the room in which such spraying is done is cleaned periodically as often as is necessary to prevent accumulation of residue, but in no case shall more than 48 hours of actual spraying operations be permitted without thoroughly cleaning the room. Exception No. 2: In any garage or other place where a spray gun is used intermittently to apply hazardous coating materials to spots on motor vehicles or other objects, such intermittent spraying operations may be carried on without booth protection only when the following regulations are observed. First. No more than one spray gun may be used at a time. Second. In each 8-hour day or shift, the total time of actual spraying operations shall not exceed 30 minutes. Third. No individual spraying job shall be greater in area than 10 square feet. Fourth. During spraying operations the operator and every other person exposed to the contaminated area shall wear an approved respirator and be otherwise protected as specified in sub. 3-c. Fifth. Where spraying operations are carried on, the room, including floor, walls and ceiling as well as fixtures and equipment, shall be cleaned at intervals as often as necessary to prevent accumulation of residue in quantities to create a fire or explosion hazard, but in no case shall more than a total of 48 hours of actual spraying be done without this thorough cleaning. Sixth. A reasonably accurate record shall be made of each separate spraying job done each calendar day. This record shall include the name of spray gun operator; time of actual spraying operations; name of article or object spray coated and name of owner; approximate area in square feet of the spot or object spray coated, and in case of a motor vehicle, the license number. These records shall be kept on file and open during reasonable hours for examination by the commissioner. Note: Failure to keep such records and to show them to the commissioner would constitute wilful violation of lawful orders of the code and subject the violator to prosecution. c. Booth Construction. c-1. Cabinet Booths. c-1-a. Type of Construction. The floor, walls and roof of every cabinet booth shall be constructed of incombustible material in such a manner as to facilitate effective maintenance and control of required ventilation. If constructed of steel, except where ceramics only are sprayed, every such booth shall be kept thoroughly painted on the inside to minimize fire hazards from possible sparks. c-1-b. Combustible Floor Covered. If the building floor on which any cabinet booth is installed is of combustible material, the floor within the booth and for a distance of 4 feet in front of the booth shall be covered with incombustible material, preferably zinc or other nonsparking metal. Exception: Small booths set on benches composed of or covered under such booths with incombustible material, and booths in which only ceramics are sprayed. c-1-c. Deflector Curtain. Every cabinet booth over 4 feet wide, measured along the floor at the front of the booth, shall be constructed with fixed incombustible deflector curtain along the upper outer edge of the booth, not less than 2-1/2 inches nor more than 5 inches. c-1-d. Inside Smooth. The inside of each cabinet booth shall be of reasonably smooth construction. Note 1. In building a booth of steel in a manner to make it incombustible, metal studs and sheathing must be used. No wood is permitted in any portion of the walls, floors, ceiling or equipment of a new booth. Note 2. If the floor of the building is of combustible material, the floor of the booth and an adequate distance in front of the booth (usually 4 feet), will need to be protected by a covering of metal or an insert of reinforced concrete 1-1/2 inches or more in thickness. It is advisable to consult the insurance carrier in any case so that accredited construction may be selected. c-2. Room Booths; Constructed of Incombustible Material. Every new booth installation of a new building, including walls, floor and ceiling, shall be constructed of incombustible material and shall be separated from other portions of the building by means of fire-resistive partitions. Every window and every door in the walls of a new room booth shall be of fire-resistive construction. Note: Before constructing a spray booth in a building, it is advisable to consult the commissioner so that the violation of general and fire protection requirements may be avoided. For example, the spray coating of automobiles is not permitted in a building having wood floors or wood walls, unless such building has been occupied for the housing, repairing or painting of automobiles continuously since September, 1918. c-3. Tunnel Booths. Every tunnel booth shall be constructed of incombustible material and shall be reasonably smooth on the inside. The ventilation of each tunnel booth shall be arranged so as to adequately protect persons within or in the immediate vicinity from the spray and fumes. c-4. Canopy Booths. Each canopy booth must be constructed of incombustible material; shall be reasonably smooth on the inside; and the ventilation shall be arranged so as to adequately protect persons under the canopy and in the immediate vicinity. d. Equipment. d-1. Electrical Equipment. All electrical equipment in connection with spray coating operations shall be installed, operated and maintained in accordance with all the requirements of ch. SPS 316, Wis. Adm. Code, complying to such locations. d-2. Sprinklers or Fire Suppression Systems Required. Every spray booth shall be equipped with one or more sprinklers or fire suppression systems installed in accordance with applicable NFPA requirements. d-3. Fire Extinguishers. Every spray booth, except where ceramics only are sprayed, shall be adequately equipped with fire extinguishers of suitable type for the nature of hazard and materials involved. d-4. Discharge Orifices. d-4-a. Free Passage of Contaminated Air. Discharge orifices shall be provided for all spray booths and shall be of such size and arrangement in each case as to permit spray-laden or contaminated air to freely pass from the booth. d-4-b. Uniform Distribution of Air Movement. Every booth of any type shall be tapered to the discharge orifice or be equipped with approved removable distribution plates or other approved means of securing reasonably uniform distribution of air motion through the booth, especially in the breathing zone. Note 1. The purpose of the tapering of a booth to the discharge orifice or of equipping a booth with distribution plates is to distribute the air flow throughout the spray booth and thus protect the operator at all points in the booth. Note 2. Where a booth is tapered toward the orifice, the angle of tapering should be not less than 45o with the plane of the front of the booth. This arrangement is preferable where dust-producing coating material, such as lacquer, is sprayed. In such cases, the spray or mist should be removed from the booth through exhaust as quickly as possible. d-4-c. Gathering of Sticky Materials. Where the spray material is such that air-borne solids are of a sticky nature, distribution plates and settling chamber shall be provided and be so arranged as to assure deposits of as much as practicable of this material. Note 1. Distribution of plates of the filter type will aid in the deposit of spray material before it reaches the fan and exhaust duct. The water wash type of booth is very satisfactory for this purpose. Note 2. Distribution plates should be placed in a plane parallel to the rear wall and distant therefrom not less than 1/4 the minimum cross section dimension of the booth. The openings through the distribution plates should be spread over the cross sectional area and should be arranged in a manner to meet the approval of the commissioner. d-5. Ventilation System Required. Every spray booth shall be suitably equipped and operated with an exhaust or ventilation system which shall protect operators, helpers and other persons in the vicinity from deposit or inhalation of the materials discharged from the spray apparatus, but the movement of air through the booth shall in no case be less than 100 lineal feet per minute in the breathing zone. Every such system shall be of such type and arrangement that efficiency of operation will be maintained independent of weather conditions. Note 1. Observations show that booth construction and arrangement, as well as the nature of the work done, have great influence on the amount of air necessary to effect the required protection. Note 2. From the standpoint of maintenance and fire protection, the indirect type of exhaust unit seems preferable. d-5-a. Fans. Each fan shall be of an effective type, capacity and performance in place so as to insure the required protection under all operating conditions, and every such fan located in a contaminated airway shall be constructed of such metals or combination of metals as to prevent sparking in practical ion, except that this latter equipment will not be required where ceramics only are sprayed. Every fan shall be substantially mounted to maintain ample clearance in use, even though the rotating parts become considerably out of balance due to deposits of paint or other cause. Fan bearings shall be of the ring-oiling or other equally effective type and should be located outside of the contaminated airways, but in any case shall be arranged to be oiled from the outside. d-5-b. Discharge Pipes. Every discharge pipe and duct conveying spray-laden or contaminated air from a booth to the outside atmosphere or to an air cleansing device, shall be as short, direct and free from resistance to air flow as practicable, based on maximum air flow at low velocities; shall be provided with means of easy access or removal for cleaning, and shall be arranged to minimize fire hazards. Each discharge pipe shall deliver to outside atmosphere above the roof of the building or to other means or device approved for the purpose. The termination of such discharge pipe delivering to outside atmosphere shall be protected by a hood of the inverted cone type or other approved device from the detrimental effects of weather and hazards due to sparks from any source and shall be arranged so as to not constitute a nuisance or fire hazard in the neighborhood. Every discharge pipe passing through a combustible wall, ceiling or roof shall be encased with incombustible material at least 4 inches thick, or with a double safety thimble made of 2 concentric rings of sheet metal, with at least one inch open air space between them and the outer ring, covered with at least 1/4 inch asbestos. There shall be no connection between the discharge or exhaust outlets of separate spray booths. d-6. Pressure Tanks and Other Containers. d-6-a. Construction and Approval. Every pressure tank supplying a spray nozzle shall be constructed and equipped as to meet the approval of the commissioner, and each tank of more than 2 gallons capacity shall be designed so that the bottom of the shell will not be subjected to wear when moved about on the floor. Note: Approval by the Underwriters' Laboratories, Inc. will be accepted by the department of neighborhood services. d-6-b. Gravity Tanks, Closed Type. Other containers supplying spray nozzles shall be of a closed type or approved with metal covers kept in place. Those not resting on the floor shall be supported on metal brackets or be suspended by wire cables. d-6-c. Capacity of Gravity Tanks Limited. No gravity tank of more than 10 gallons capacity shall be used to supply a spray nozzle. d-6-d. Clamping Devices for Shipping Drums Used as Pressure Tanks. Where the original shipping drum is used to supply a spray nozzle by the pressure system, the drum shall be clamped in a suitable device to prevent the drum from bursting. d-6-e. Protective Clothing Required. The entire person, except face and neck of the spray operator and his helper, shall be protected by suitable clothing and equipment during spraying operations. Exception: Where ceramics only are applied. e. Air Supply. e-1. Quality. Uncontaminated, tempered air shall be furnished and maintained within the breathing zone of each operator of every spray booth. e-2. Quantity. The air supplied to each room containing or constituting any spray booth shall be admitted by natural or mechanical means and the volume shall be at least equal to that removed from such an enclosure by the booth exhaust fan or other ventilation system. Note 1. Where a cabinet booth is located in a building or room where the volume of properly tempered air exhausted through the booth is only a small portion of that available, and the withdrawal of this tempered air is such that it does not appreciably affect the air conditions or distribution in other working areas, it is not necessary to provide air supply for the booth exhaust other than through the general ventilating system. Often, however, means must be provided for supplying tempered air to replace that exhausted through the booth. This can be accomplished by natural or mechanical means. In any case, the air from the source of supply, ordinarily outside the building, is caused to pass through or in contact with heating units. Note 2. The air supply for the spray booth should be delivered at a point, or points, as far from the booth as other operations in the building will permit. Note 3. The air required to supply the exhaust or ventilating system in any room booth should be properly tempered, clean air from an outside source supplied directly to the room. Note 4. In any case, the arrangements for the exhaust and supply of air should be such as not to produce an excessive draft or vacuum in any area outside of the booth. e-3. Direction of Air Flow in Booths. The direction of air flow in any booth shall be from the operators and helpers toward the objects or work being spray coated and thence to the discharge orifice of the booth. f. Maintenance. f-1. Cleanliness. f-1-a. Booths Periodically Cleaned. Every booth in which spray coating is done shall be cleaned thoroughly at reasonably frequent intervals, but in no case shall a booth be used for more than 48 hours of spraying operation without cleaning. Exception: Parts and equipment located in the air stream beyond the water curtain of any approved water wash booth. Note 1. Each fan shall be cleaned at regular intervals because deposits of spraying materials seriously reduce the efficiency of the fan and constitute a fire hazard except when spraying ceramics. Likewise, air passages, chambers and ducts should be cleaned regularly for the same reasons. Note 2. Distribution plates and similar removable parts should be cleaned in an isolated or protected location to reduce the fire hazard. Note 3. Only nonsparking tools should be used for cleaning or making repairs. f-1-b. Spray Rooms Periodically Cleaned. Each room where a spray booth is located shall be thoroughly cleaned at least once every year where spray coating is done regularly, or at least once every 2 years where spray coating is done intermittently. f-2. Storage of Materials. f-2-a. Volatile Liquids. The main supply of solvents, paints, lacquers and other volatile materials shall be stored in a location remote from the spraying process, preferably in an outside oil house or an especially constructed room. Each container for such material to be used in the vicinity of the booth shall be tightly covered when not in use. f-2-b. Booths Not Store Rooms. No material or equipment shall be stored in any spray booth. Note: Isolated mixing rooms and pipe line circulation systems are recommended in every case where the spraying operations are extensively continuous.
Ask a question about Milwaukee law
Corpus searches the Milwaukee sections it holds and shows the ones that match, with their citations. Free, no sign-in.