Sec. 9.937. - Visibility.
(a) Purpose and Intent. The following regulations employ natural surveillance, natural access management, and territorial reinforcement techniques to establish a safe and comfortable environment. These regulations are intended to facilitate a clear, unobstructed view into and out of establishments, ensure customers can see and be seen when entering and leaving the premises, provide physical orientation and a pedestrian-friendly environment, and to discourage would-be offenders by making noncompliance obvious.
(b) Effective date.
(1) All existing windows shall comply with window coverage, interior fixture, window treatment, transparency, entrance identification, and security device requirements of this Section after the effective date of this Chapter.
(2) Improvements to customer entrances and parking areas, as described in this Section, shall be installed within three (3) years after the effective date of this Chapter. Glass replacement at customer entrances in order to meet transparency requirements shall comply after the effective date of this Chapter.
(c) Identification. Customer entrances shall be clearly identifiable by means of signage, architectural features, awnings, lighting, or other means, as otherwise permitted by other City codes and ordinances.
(d) Window Coverage. The view from outside of the building through windows, doors or other transparent surfaces shall not be obstructed or blocked by more than twenty-five (25) percent by any painted, stenciled, applied sign or film; bars or other security device; interior display, shelving, cooler, furniture; or other solid fixtures or covering, separately or in combination, except as outlined below. Window panes separated by muntins shall not be counted separately as windows but shall be included in the cumulative total square footage of window area.
(e) Interior fixtures. Movable fixtures including but not limited to interior displays, shelving, coolers, furniture, or other solid, movable fixtures above three (3) feet in height located on the interior of the establishment shall be set back a minimum of five (5) feet from the window. Interior fixtures closer than five (5) feet from the window shall be considered window coverage.
(f) Window treatments. Shades, blinds, curtains or other window treatments shall allow visibility into the establishment from the outside during business hours but may be used to temporarily filter or block direct sunlight during hours of operation.
(g) Transparency.
(1) Glass in ground floor windows, doors, and display windows shall be transparent or lightly tinted, maintain a visible light transmittance measurement of at least sixty-eight (68) percent, and have a reflectivity value of no greater than twelve (12) percent from both inside and outside. Mirrored or darkly tinted glass is not permitted.
(2) The area of the front and sides of a building between two (2) and eight (8) feet above the sidewalk (or ground level adjacent to the building if a sidewalk is not present) shall be used to measure transparency.
(h) Customer Entrance.
(1) Doors used for customer entry and exit shall be transparent or contain a transparent viewing window. The viewing window shall be located in the upper half of the door, be at least thirty (30) percent of the area of the door and be situated in a manner that promotes visibility from both sides of the door. Completely solid or opaque doors are not permitted.
(2) The primary building entrance shall be in the front façade parallel to the street and readily visible from the public right-of-way. At least one (1) main building entrance shall be located on the primary street.
(i) Security Devices.
(1) Steel barriers, shutters, hurricane curtains and other similar security devices are not permitted on the exterior of the building. If located inside the building, they may not be visible from the public sidewalk or right-of-way during business hours.
(2) Security bars or other similar devices are permitted, subject to Section (b), above. Security bars count against window coverage.
(j) Parking area. A parking area abutting and associated with an establishment shall be readily viewed from inside the building by means of either a camera part of a functioning video surveillance system, or by a transparent window of at least six (6) square feet in area for every forty (40) linear feet or portion thereof of the wall(s) of a building that faces the parking area.
(k) Administrative Departures.
(1) An administrative departure may be granted for interior fixtures where minimum building transparency requirements listed in Building Elements tables of Articles 5, 6 and 7 of the Zoning Ordinance are satisfied.
(2) An administrative departure may be granted from window coverage, window treatment, or transparency requirements for non-compliant existing windows if another existing window is increased in size, or a new window is added, on the building façade commensurate with the area of the existing window that shall remain covered or non-transparent due to the operating needs of the business.
(3) An administrative departure may be granted for the placement of the customer entrance door if the building entrance is located within five (5) feet of a front corner of the building so long as the corner area of the entrance is at least sixty (60) percent transparent on the street-facing side and situated in a manner that promotes visibility from the public right-of-way.
(Ord. No. 2019-44, § 1, 8-27-19)