§ 15-3906 — BUILDING AND MECHANICAL CONDITIONS
Fresno Municipal Code (Supp. No. 55, Update 1 (online June 23, 2026): codified through Ordinance No. 2026-019) · Fresno Municipal Code § 15-3906
Corpus is an independent public-information project, not the official City of Fresno website. Stable reference: corpuslaw.us/code/ce5eaa68-52bd-4e64-a958-97030d09e2e7
Sec. 15-3906. - BUILDING AND MECHANICAL CONDITIONS.
The following shall be inspected and approved by the Building Official. A. Housing Regulations. The project shall conform to the applicable standards of the City Housing Code. B. Electrical Requirements. 1. All indoor and outdoor receptacles shall have three-wire grounding. 2. Ground-fault circuit interrupters shall be provided in areas as required by the Building Official. 3. All bedrooms shall have at least four receptacles. 4. The combined living and dining room area shall be provided with at least four receptacles. 5. A receptacle shall be provided for kitchen counter space of more than 30 linear inches. 6. Separate electrical meters and overcurrent devices shall be provided for each unit. 7. Any other electrical systems deemed necessary. C. Plumbing Requirements. All cross-connections shall be corrected. D. Building Requirements. 1. Access shall be provided for the entire attic area. 2. Draft stops shall be provided in the attic area. 3. All glass doors and panels subject to human impact shall comply with Federal Glazing Standards. 4. All applicable provisions of the Municipal Code relating to stairs, exits, and occupant loads, and to fire extinguishing systems. 5. Smoke/Carbon Monoxide alarms, of a type and in numbers and locations as per the Building Code as approved by the Building Official, shall be installed. 6. Each sleeping area shall be provided with a window of a size and in a location which will allow its use as an emergency exit. 7. Compliance with the applicable provisions of the California Fire Code, as adopted in Chapter 10, Article 5 of the Fresno Municipal Code, shall be required. The installation of fire sprinklers is required in accordance with NFPA 13R for multi-unit residential buildings. For buildings with existing fire sprinkler systems, all portions of the system shall be inspected, repaired as necessary, and certified as to full compliance with applicable standards by a licensed fire sprinkler contractor. 8. The applicable provisions of relevant State and local codes. E. Mechanical Requirements. All combustion air for water heaters, furnaces, and clothes dryers shall be provided from outside the building. F. Energy Requirements. 1. R-11 wall insulation and R-19 ceiling insulation shall be provided for each unit. 2. All exterior doors and windows shall be weather-stripped. 3. Heating and cooling air ducts shall be insulated according to the requirements of the Uniform Mechanical Code. 4. Heating and cooling air duct joints shall be sealed with pressure-sensitive tape. 5. Heat pumps with electric resistance back-up shall be controlled with a two-stage thermostat. G. Noise Requirements. An interior noise level of no more than 45 dB CNEL attributable to exterior sources shall be allowable in any dwelling unit.
(Added Ord. 2015-39, § 1, eff. 1-9-16; Am. Ord. 2025-024, § 71, eff. 7-27-25).
Ask a question about Fresno law
Corpus searches the Fresno sections it holds and shows the ones that match, with their citations. Free, no sign-in.