§ 2-75 — MU-G (Mixed-Use Greenfield and Large Lot) district
Code of Ordinances, City of Round Rock, Texas (Supp. 27: codified through Ordinance of August 13, 2026 (online updated November 5, 2026)) · Round Rock Zoning and Development Code, art. VI, § 2-75
Corpus is an independent public-information project, not the official City of Round Rock website. Stable reference: corpuslaw.us/code/ce8de2f6-64b7-42f5-a385-9af1121d2dee
Sec. 2-75. - MU-G (Mixed-Use Greenfield and Large Lot) district.
(a) Purpose. (1) To establish areas of mixed land uses for the comprehensive development of a mixed-use project that includes a large tract of land and one of the following conditions: a. Where commercial zoning districts and a residential component could not otherwise be accommodated; b. Where desired development or redevelopment cannot be accommodated with existing commercial zoning standards; or c. Where the desired development is of an urban scale which is oriented toward the pedestrian. (2) This district is intended to serve as the base zoning district in PUD negotiations for developers to utilize for new, large mixed-use development. (3) Mixed-use zoning for this district refers to the combining of complementary residential and commercial uses in the same building, on the same site, or in the same block. The standards herein are not intended to be of a particular style or period, but to encourage high-quality construction and development that fits the proportions and functional characteristics of a mixed-use district with an urban and pedestrian-oriented feel. (4) This district is intended to serve as an option for property owners to use for new, large-scale mixed-use development instead of creating a PUD, or as the base zoning district in PUD negotiations. (b) Site and land use criteria. The following site and land use criteria shall be provided for all proposed projects: (1) The total acreage of the project, which shall be a minimum of 10 acres. (2) A general plan indicating the layout, land uses, and percentages of each land use. (3) Allocation of open space accessible to the public comprising a minimum of 15% of the total acreage. (4) Each project shall have a designated main street which is configured in a block layout and serves as the core of each development. a. The maximum block size shall be three (3) acres in size and 400 feet in length. b. Buildings on the main street shall have their primary façade facing the main street. c. The design of building facades in the first block off the main street shall reflect the design of the buildings on the main street. (5) A minimum of two (2) land use/zoning categories (residential, commercial, employment) shall be identified. a. If a development is entirely nonresidential it shall have at least one (1) of the following: 1. Any type of residential neighborhood or multifamily development abutting at least one (1) side of the proposed project. 2. The entirety of the proposed project fronts on a multi-lane divided roadway and is on average not more than one (1) block in depth according to the measurement standards for blocks provided within this section. 3. The proposed project contains a building with overnight accommodations that occupies a minimum of four (4) stories. b. When residential uses are incorporated into a project, the first phase of the project shall meet at least one (1) of the following criteria: 1. All development abutting a thoroughfare shall have nonresidential uses on at least seventy-five (75%) percent of the ground floor of buildings. 2. At least forty (40%) percent of any building(s) shall be allocated to nonresidential uses. 3. For buildings in the first phase of a project to include more than sixty (60%) percent residential, all multi-unit residential buildings shall have units accessed from the interior of the building without exterior stairs to access main entrances of units. (c) Thoroughfare criteria. A general plan indicating the internal roadway system throughout a proposed project shall be provided. Special emphasis should be placed on a roadway system that emphasizes a grid pattern that allows for pedestrian linkages and visual enhancements. Street design should encourage commercial and residential buildings with a build-to line without intervening parking between buildings, sidewalks and roads, and provides for community-serving retail, commercial, office and services uses available to those that access the site as pedestrians or in vehicles. (1) The following thoroughfare provisions shall be required of all proposed projects: a. All streets shall be private streets, unless the city agrees to accept dedication of some or all as public streets. Private street standards shall be subject to city approval. b. All streets shall be open for public use and shall not be gated or have restricted access, except for permitted special events. c. A private street lot or public right-of-way may vary in width but must be sufficient to accommodate travel lanes, medians, sidewalks, utilities, street furniture and fixtures, and landscaping of public or common ownership. d. Street design. 1. All proposed projects shall have a main street which serves as the core of the project and is designed in accordance with the "Walkable Thoroughfares" standards in the table in subsection (c)(2) below. No parking garages or surface parking lots shall have a driveway on the main street. 2. Street design shall allow a variety of routes from point of origin to destination. 3. Street design shall allow for parking on one or both sides of the road. 4. Street design shall provide continuous landscaping, especially for shade trees. 5. Culs-de-sac shall be prohibited. e. Pedestrian orientation. The individual uses, buildings, and clusters of development within a mixed-use project shall provide the following: 1. Interconnecting pedestrian areas including but not limited to sidewalks, plazas, and trails. 2. Pedestrian connections to the City's parks and trails system where applicable. 3. Internalized pedestrian connections between residential and nonresidential land uses. 4. Multi-modal transportation access where applicable. (2) The following table shall serve as guidelines for the development of the streetscape and pedestrian realm within the PUD. The source of the table is "Designing Walkable Urban Thoroughfares: A Context Sensitive Approach" (RP-036A) published in 2010 by the Institute of Transportation Engineers in partnership with the Congress for the New Urbanism. Characteristic | Walkable Thoroughfares | Vehicle-Oriented Thoroughfares Target speed range | 15—25 mph | 25—35 mph Pedestrian separation from moving traffic | Curb parking and streetside furnishing | Optional, typically separation achieved with planting strip. Streetside width | Minimum 9 feet (residential) and 12 feet (commercial) to accommodate sidewalk, landscaping and street furniture. | Minimum 5 feet Block lengths | 200—660 feet | Up to one-quarter of a mile Protected pedestrian crossing frequency (pedestrian signals or high-visibility markings at unsignalized crossings) | 200—600 feet | As needed to accommodate pedestrian demands Pedestrian priority at signalized intersection | Pedestrian signals and pedestrian countdown heads, adequate crossing times, shorter cycle lengths and median refuges for very long crossings. | Vehicle priority; may have longer cycle lengths and require two cycles for slower pedestrians to cross wide streets with medians. Pedestrian crossings | High-visibility crosswalks shortened by curb extensions where there is on-street parking. | Full street-width Median width | 6 feet minimum width at crosswalk, if used as pedestrian refuge, plus 10 feet for left turn lane, if provided. 14-foot total width for left-turn lane if no refuge needed. | 14—18 feet for single left-turn lane; 26—30 feet for double left-turn lane. Vehicular access across sidewalks | 24 feet or less, except if specific frequent design vehicle requires added width. | As needed Curb parking | Normal condition except at bus stops and pedestrian crossings. | None Curb return radius | 10—30 feet; low-speed channelized right turns where other options are unworkable. | 30—75 feet; high-volume turns channelized. (d) Permitted uses. (1) All uses shall be permitted, with the exception of the prohibited uses listed in Sec. 2-91 and the following: single-family detached with the exception of zero lot line and village lots; manufactured housing; two-family; funeral home/mortuary, cemetery, mausoleum, columbarium, and memorial park; institutions; auto service facilities; car wash; self-service storage; vehicle sales, rental, or leasing facilities; auto body, painting and repair shops; fuel sales; pawn shops; sexually oriented businesses; taxidermists; retail sales and service consisting of predominantly outdoor storage or consumer loading areas; light industrial services including manufacturing and assembly; wholesale trade; outdoor kennels; livestock veterinary clinics; warehouse and freight movement; large vehicle and equipment repair; heavy equipment sales and leasing; vehicle storage and towing; waste-related services; agricultural operations; fowl or livestock raising; mineral extraction; and commercial parking with the exception of multistory structured parking. (2) The following uses are permitted only with a special exception granted by the ZBA: outdoor entertainment, passenger terminals. (e) Baseline lot and building dimensional standards. Property and buildings in the MU-G district shall utilize the standards found in Sec. 2-78 as the baseline in PUD negotiations, with the following supplementary notes: (1) Special purpose lots, such as landscape lots and utility lots, are exempted from these requirements. (2) For courtyard multifamily, the front setback from the street (ROW) may be more than the maximum as long as the courtyard fills the space from the maximum setback to the façade of any building. (3) Side wall requirements for separation from adjacent structures, wall construction, and allowable openings for elements such as windows and doors shall be regulated by the Fire Code. (4) Number of stories includes mezzanines or other occupiable levels. Rooftop decks and patios shall not be included in the number of stories, but structures placed on rooftop decks and patios shall qualify towards the height requirement. (5) Fences may be eight (8) feet in height to accommodate topographical changes, as approved by the Zoning Administrator. (f) Baseline supplementary development standards. In addition to the applicable standards found in Chapter 8 of this Code, the following regulations shall provide the baseline for PUD negotiations for the MU-G district: (1) Parking. The following standards are meant to encourage a pedestrian-friendly environment by minimizing curb cuts. On-site parking shall be placed in an unobtrusive location that minimizes impacts to pedestrian circulation. a. On-site parking. 1. Due to the variable nature of uses and lot sizes, a parking generation study shall be provided with each development application for all nonresidential uses. The parking generation study shall include the following criteria: i. A demand analysis of parking need based on industry standards. ii. Characteristics of those using parking, including turnover rate. 2. On-site parking shall be required for all residential uses, or residential portions of any building. i. Required residential parking per unit: 1 Bedroom: 1 space 2 Bedrooms or more: 2 spaces ii. For residential units without defined bedrooms: Under 800 square feet: 1 space 800 square feet or more: 2 spaces iii. Tandem parking shall be permitted to accommodate the residential parking requirement. 3. Alternative solutions may include a shared parking agreement as described in Sec. 8-47 or other solution as approved by the Public Works Director. b. All parking shall be constructed in accordance with the following requirements in addition to standards provided in chapter 8, article VI of this Code: 1. Parking and access shall be permitted only on improved surfaces. 2. Vehicular access shall be from the secondary frontage where possible. 3. Vehicular entrances to all parking areas shall be no wider than the minimum standard allowed by the Design and Construction Standards. 4. On-site parking areas are prohibited in any front street yard of any internal thoroughfare, and all parking shall be setback a minimum of five (5) feet from any thoroughfare-facing building façade. No parking shall be permitted in any street yard of a public right-of-way. 5. On-site parking areas visible from a public right-of-way shall be screened by a building or wall, hedge or other landscaping screen that is at least three (3) feet in height. c. Thoroughfare parking. 1. Parking adjacent to the property may be used to fulfill a parking requirement determined in a parking generation study, as determined by the zoning administrator. The materials, design and location of the parking improvements shall be approved by the City. d. Structured parking. All structured parking garages where any of the parking is above grade shall meet the following standards: 1. The first 20 feet in height of the frontage of a garage that faces a public street, with the exception of pedestrian and vehicular ingress and egress areas, shall require either a ground-level use or vehicle parking areas to be screened from view from a public street by means of landscaping or manufactured materials. 2. Exterior garage building materials shall be limited to natural stone, simulated stone, brick, split-face or stone-face concrete masonry units (CMU), or architecturally finished steel or metal. 3. The glazing percentage requirements provided in subsection (h)(2) below shall apply to ground-level occupant spaces, if any. 4. Pedestrian access. i. Pedestrian ingress and egress to all parking structures shall provide access directly to a street or public frontage except for underground parking levels, where pedestrians may exit the parking area directly into a building. ii. Pedestrians shall have direct access from parking areas to the street on the primary frontage. iii. There shall be direct access to the street from commercial uses. 5. Vehicular access shall be from the secondary frontage where possible. 6. Service access shall be from an alley where possible. Where an alley does not exist, service access shall be from a secondary frontage where one exists and shall be enclosed or screened from view. (2) Traffic impact analysis. A Traffic Impact Analysis (TIA) shall be required for any development in the MU-G district. (3) Access and circulation. a. Vehicle access and circulation standards provided in Sec. 8-60 apply to all new development. These include requirements for connections to existing and future roads, connection to adjacent development, and design requirements for driveways. b. Drive-throughs shall be prohibited except on lots fronting arterials, as defined by the Transportation Master Plan. The following conditions shall apply to any site where a drive-through is incorporated: 1. Only one (1) business on a site shall have a drive-through. 2. Drive-throughs shall be part of a building containing two (2) or more occupants or uses. 3. The primary use associated with the drive-through shall not occupy more than 50 percent of the gross floor area of a single-story building. For multi-story buildings, the principal use may occupy the entire first floor. 4. Off-street vehicle stacking spaces are prohibited in any front street yard and shall meet the stacking area standards and design provided in Sec. 8-52. 5. Vehicular entrances and exits shall be no wider than the minimum required for one (1) vehicle and shall be in accordance with the Design and Construction Standards. (4) Lot fencing design standards. The following standards apply to fencing in the MU-G district, in addition to the applicable standards found in Sec. 8-35: a. Fences shall be constructed of brick, natural stone, simulated stone, or shall be view fencing. Other decorative masonry materials, reinforced concrete, or view fencing equivalents may be approved by the Zoning Administrator. (5) Landscaping. a. Where the building setback provides adequate space, landscaping foundation treatment shall be required in accordance with the Category 3 standards in Sec. 8-10. b. Minor modifications to design and development standards may be permitted to protect and accommodate protected trees as identified in chapter 8, article III. c. Screening for parking shall be in accordance with subsection (f)(2)b.5. above. d. Pervious concrete and pervious pavers for parking and maneuvering areas are permitted. Other permeable surfaces may be approved by the Zoning Administrator. (6) Outdoor storage and display. a. General outdoor storage is prohibited. b. Outdoor display and limited outdoor storage shall be allowed in accordance with Sec. 8-65. c. Limited outdoor storage is prohibited in the street yard. (7) Site furniture. a. Site furniture for nonresidential uses, as defined in Sec. 1-50, shall be required to be of a commercial grade and manufactured for exterior use. b. Site furniture may also include moveable outdoor site features such as outdoor café tables and planters. (8) Special conditions for open spaces including parks, trails, creeks, and plazas. a. No opaque fences shall be allowed on the portion of a lot abutting any public open space. Wrought iron fencing or equivalent may be used. b. There shall be no loading or service areas between the buildings and open spaces. c. An eight (8) foot wide linear landscaped area in accordance with Sec. 8-10(g)(3) shall be required on lots abutting public open space that have their parking between the buildings and the public open space. If site constraints inhibit the incorporation of the required landscaped area, alternative landscaping may be approved by the Zoning Administrator. (g) Baseline design standards. The following design standards shall be utilized as the baseline for PUD negotiations for all buildings in the MU-G District. (1) Exterior wall finish. The exterior finish of all buildings shall be natural stone, simulated stone, brick, architectural concrete masonry units (CMU), glass, stucco, fiber cement siding (excluding flat, unarticulated panels), or architecturally finished steel or metal, except for doors, windows, accents and trim. a. Fiber cement siding shall not comprise more than 33 percent of the exterior wall finish. b. If architectural CMU is incorporated into a project, it shall have an ashlar pattern. c. The use of materials such as wood shingles and wood siding shall be limited to accent features. d. Other wall materials or recognized architectural styles not explicitly permitted by this section may be approved in writing by the Zoning Administrator. (2) Orientation requirements. a. Buildings shall have their main entrance off a thoroughfare or plaza. Entrances shall be easily accessible for pedestrians from the street, a plaza or the sidewalk. b. Buildings on corner lots shall be designed with primary facades facing each thoroughfare. (3) Building elevation variation. a. For buildings on the main street, the length of walls facing any street shall be broken into smaller planes. Wall planes shall not extend more than an average of 50 feet without an offset or interruption by a pilaster or structural frames, change in roof line or architectural materials. b. The composition of windows and other major features shall relate to the wall plane between each offset or other feature identified in subsection (g)(3)a, immediately above. c. For buildings on any thoroughfare, any wall facing the street in excess of 100 feet in length shall incorporate wall plane projections or recesses having a depth of at least two (2) feet and extending at least 20 percent of the length of the facade. No uninterrupted length of any facade shall exceed 100 horizontal feet. (4) Roofing materials. a. Roofing materials for pitched roofs shall consist of a minimum 25-year architectural dimensional shingles, tile (clay, cement, natural or simulated stone), non-reflective prefinished metal, copper or other similar materials as approved by the Zoning Administrator. b. All roof-mounted mechanical equipment shall be screened from public view by parapets or other opaque screening materials so as to not be visible from an abutting street, public plaza or public open space. The parapet or screen shall utilize the same or similar materials as the principal structure. (5) Glass. Except for photovoltaic cells, mirrored glass with a reflectivity of 20 percent or more is prohibited on the exterior walls and roofs of buildings and structures. (h) MU-G district design standards for buildings within one (1) block of the main street. (1) Building articulation. a. All buildings shall be designed to include varied relief to provide interest and variety and to avoid monotony. This shall include details that create shade and cast shadows to provide visual relief to the buildings. Horizontal and vertical elements of exterior walls should vary in height, design and projection to provide architectural interest and style. b. The following is a list of design features that may be used as part of an integrated, comprehensive building design to provide architectural interest and style. Such interest and style shall include a minimum of five (5) of the following: 1. Decorative cornices. 2. Eaves. 3. Bow window. 4. Bay window. 5. Arched window. 6. Gable window. 7. Transom windows. 8. Multiple sashed and/or paned upper story windows. 9. Oval or round windows. 10. Shutters. 11. Arched entry, balcony or breezeway entrance. 12. Recessed entryways. 13. Storefront (for retail uses). 14. Arcade/Gallery (for retail uses). 15. Stone or brick accent wall. 16. Decorative stone or brick band. 17. Decorative tile. 18. Veranda, porch or balcony. 19. Projected wall or dormer. 20. Variation of roof lines on the building. 21. Decorative caps and chimneys. 22. Stone coursing around windows. 23. Metal canopies. 24. Fabric awnings that relate to window and door bays. 25. Other features as approved by the zoning administrator. (2) Windows. In order to ensure appropriate proportion, shape, position, location, pattern and size of windows on a building, the following shall be required: a. The ground floor of the primary façade shall have a minimum of 40 percent glazing. All glazing on the primary façade of the ground floor shall have a light transmittance of 70 percent. b. Upper floors of the primary façade shall have a minimum of 30 percent glazing. c. At least 25 percent of the wall area on any side or rear elevation facing a park or plaza shall consist of glazing or as permitted by the Building Code, whichever is less. d. To assist with energy efficiency and solar gain the requirements in this subsection may be reduced by the Zoning Administrator to the extent that the required level or location of glazing conflicts with the standards of the Building Code or a recognized green building program. (3) Awnings and canopies. Awnings and canopies attached to buildings shall meet the following standards: a. Awnings and canopies shall be placed so as to avoid obscuring details of the building façade. b. Fabric awnings for windows shall be a drop-front style, except at arched window openings, and shall relate to each window or bay. c. Awnings and canopies shall be placed so that there is a minimum clearance of eight (8) feet at its lowest point when over a sidewalk or other pedestrian walkway. d. Awnings and canopies may encroach up to 10 feet or 66 percent of the distance from the building face to the curb, whichever is less.
(Ord. No. O-2020-0158, § IX, 6-11-2020; Ord. No. O-2024-266, § XXVI, 9-26-2024; Ord. No. O-2026-119, § V, 5-14-2026; Ord. No. O-2026-220, § XII, 8-13-2026)
Ask a question about Round Rock law
Corpus searches the Round Rock sections it holds and shows the ones that match, with their citations. Free, no sign-in.
