§ 14.04.170 — Section 2305.4 is added to the 2025 Edition of the California Building Code to read as follows
Pasadena Municipal Code, California (Supp. No. 79: codified through Ordinance No. 7469, enacted May 18, 2026) · Pasadena Municipal Code § 14.04.170
Corpus is an independent public-information project, not the official City of Pasadena website. Stable reference: corpuslaw.us/code/cf28bebd-8bcf-4901-969f-bc5b3f3df9be
14.04.170 - Section 2305.4 is added to the 2025 Edition of the California Building Code to read as follows.
2305.4 Hold-down connectors. In Seismic Design Category D, E or F, hold-down connectors shall be designed to resist shear wall overturning moments using approved cyclic load values or 75 percent of the allowable seismic load values that do not consider cyclic loading of the product. Connector bolts into wood framing shall require steel plate washers on the post on the opposite side of the anchorage device. Plate size shall be a minimum of 0.229 inch by 3 inches by 3 inches (5.82 mm by 76 mm by 76 mm) in size. Hold-down connectors shall be tightened to finger tight plus one half (1/2) wrench turn just prior to covering the wall framing.
(Ord. No. 7461, § 5, 11-10-2025)