For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8-103 — Amendments to the International Building Code (2024 edition)

Code of Ordinances, City of Round Rock, Texas (Supp. 27: codified through Ordinance of August 13, 2026 (online updated November 5, 2026)) · Round Rock Zoning and Development Code, art. X, § 8-103

Corpus is an independent public-information project, not the official City of Round Rock website. Stable reference: corpuslaw.us/code/cfad42fc-6321-4c20-8090-4a06d6984188

Sec. 8-103. - Amendments to the International Building Code (2024 edition).

(a) The International Building Code is amended as follows: (1) Section 101.1. Inserted: City of Round Rock, Texas. (2) Section 1612.3. Inserted: City of Round Rock, Texas. (3) Section 1612.3. Inserted: of most current date. (4) Section 915.1. Amended to read: General. New and existing buildings shall be provided with carbon monoxide (CO) detection in accordance with sections 915.2 and 915.5. (5) Section 915.1.1. Section 915.1.1 is repealed in its entirety. (6) Section 915.2. Amended to read: Where required. Carbon monoxide detections shall be provided in interior spaces, including Group B fire areas containing animal housing or care facilities, other than dwelling units or sleeping units, that are exposed to a carbon monoxide source in accordance with sections 915.2.1 through 915.2.3. Carbon monoxide detection for dwelling units or sleeping units that are exposed to a carbon monoxide source shall be in accordance with section 915.2.4. (7) Section 915.2.1. Amended to read: Interior spaces with direct carbon monoxide sources. In all occupancies, including Group B fire areas containing animal housing or care facilities, interior spaces with a direct carbon monoxide source shall be provided with carbon monoxide detection located in close proximity to the direct carbon monoxide source and in accordance with section 915.3. Exception: Where environmental conditions in an enclosed space are incompatible with carbon monoxide detection devices, carbon monoxide detection shall be provided in an approved adjacent location. (8) Section 915.2.2. Amended to read: Interior spaces adjacent to a space containing a carbon monoxide source. In Groups A, B, E, I, M, and R occupancies, including Group B fire areas containing animal housing or care facilities, interior spaces that are separated from and adjacent to an enclosed parking garage or an interior space that contains a direct carbon monoxide source shall be provided with carbon monoxide detection if there are communicating openings between the spaces. Detection devices shall be located in close proximity to communicating openings on the side that is furthest from the carbon monoxide source and in accordance with section 915.3. Exceptions: 1. Where communicating openings between the space containing a direct carbon monoxide source and the adjacent space are permanently sealed airtight, carbon monoxide detection is not required for the adjacent space. 2. Where the fire code official determines that the volume or configuration of the adjacent interior space is such that dilution or geometry would diminish the effectiveness of carbon monoxide detection devices in such spaces, detection devices additional to those required in section 915.2.1 shall be located on the side of communicating openings that is closest to the carbon monoxide source. (9) Section 915.2.3. Amended to read: Interior spaces with forced-indirect carbon monoxide sources. In all occupancies including Group B fire areas containing animal housing or care facilities, interior spaces with forced-indirect carbon monoxide source shall be provided with carbon monoxide detection in accordance with either of the following: 1. Detection in each space with a forced-indirect carbon monoxide source, located in accordance with section 915.3. 2. Detection only in the first space served by the main duct leaving the forced-indirect carbon monoxide source, located in accordance with section 915.3, with an audible and visual alarm signal provided at an approved location. (10) Section 915.2.4. Amended to read: Dwelling units and sleeping units. Carbon monoxide detection for dwelling units and sleeping units shall comply with sections 915.2.4.1 and 915.2.4.2. (11) Section 915.2.4. The exceptions in section 915.2.4 are repealed in their entirety. (12) Section 915.2.4.1. Added to read: Direct carbon monoxide sources. Where a direct carbon monoxide source is located in a bedroom or sleeping room, or bathroom attached to either, including Group B fire areas containing animal housing or care facilities, carbon monoxide detection, shall be installed in the bedroom or sleeping room. Where carbon monoxide detection is not installed in bedrooms or sleeping rooms, carbon monoxide detection shall be installed outside of each separate sleeping area in close proximity to bedrooms or sleeping rooms for either of the following conditions: 1. The dwelling unit or sleeping unit has a communicating opening to an attached, enclosed garage. 2. A direct carbon monoxide source is located in the dwelling unit or sleeping unit outside of bedrooms or sleeping rooms. (13) Section 915.2.4.2. Added to read: Forced-indirect carbon monoxide sources. Bedrooms or sleeping rooms, including Group B fire areas containing animal housing or care facilities, in dwelling units or sleeping units that are exposed to a forced-indirect carbon monoxide source shall be provided with carbon monoxide detection in accordance with section 915.2.4.1 or section 915.2.3. (14) Section 915.2.5. Section 915.2.5 is repealed in its entirety including the exceptions. (15) Section 915.2.6. Section 915.2.6 is repealed in its entirety including the exception. (16) Section 915.3. Amended to read: Location of detection devices. Carbon monoxide detection devices shall be installed in accordance with the manufacturer's instructions in a location that avoids dead air spaces, turbulent air spaces, fresh air returns, open windows, and obstructions that would inhibit accumulation of carbon monoxide at the detection location. Carbon monoxide detection in air ducts or plenums shall not be permitted as an alternative to required detection locations. (17) Section 915.3.1. Section 915.3.1 is repealed in its entirety. (18) Section 915.3.2. Section 915.3.2 is repealed in its entirety. (19) Section 915.3.3. Section 915.3.3 is repealed in its entirety. (20) Section 915.3.4. Section 915.3.4 is repealed in its entirety. (21) Section 915.4. Amended to read: Permissible detection devices. Carbon monoxide detection shall be provided by a carbon monoxide detection system complying with section 915.4.2 unless carbon monoxide alarms are permitted by sections 915.4.1. (22) Section 915.4.1. Amended to read: Carbon monoxide alarms. Carbon monoxide alarms complying with sections 915.4.1.1 through 915.4.1.3 shall be permitted in lieu of a carbon monoxide detection system in both the following: 1. Dwelling units and sleeping units. 2. Locations other than dwelling units or sleeping units, where approved, provided that the manufacturer's instructions do not prohibit installation in locations other than dwelling units or sleeping units and that the alarm signal for any carbon monoxide alarm installed in a normally unoccupied location is annunciated by an audible and visual sign in an approved location. (23) Section 915.4.1.1. A new subsection 915.4.1.1 is added to read: Power source. In buildings with a wired power source, carbon monoxide alarms shall receive their primary power from a permanent connection to building wiring, with no disconnecting means other than for overcurrent protection, and shall be provided with a battery backup. In buildings without a wired power source, carbon monoxide alarms shall be battery powered, (24) Section 915.4.1.2. A new subsection 915.4.1.2 is added to read: Listings. Carbon monoxide alarms shall be listed in accordance with UL 2034. Combination carbon monoxide/smoke alarms shall also be listed in accordance with UL 217. (25) Section 915.4.1.3. A new subsection 915.4.1.3 is added to read: Interconnection. When more than one carbon monoxide alarm is installed, actuation of any alarm shall cause all of the alarms to signal an alarm condition. (26) Amended to read: Carbon monoxide detection systems. Carbon monoxide detection systems shall be installed in accordance with NFPA 72. (27) Section 915.4.2.1. A new subsection 915.4.2.1 is added to read: Fire alarm system integration. Where a building fire alarm system or combination fire alarm system, as defined in NFPA 72, is installed, carbon monoxide detection shall be provided by connecting carbon monoxide detectors to the fire alarm system. Where a building fire alarm system or combination fire alarm system is not installed, carbon monoxide detection shall be provided by connecting carbon monoxide detectors to a carbon monoxide detection system complying with NFPA 72. (28) Section 915.4.2.2. A new subsection 415.4.2.2 is added to read: Listings. Carbon monoxide detectors shall be listed in accordance with UL 2075. Combination carbon monoxide/smoke detectors shall be listed in accordance with UL 268 and UL 2075. (29) Section 915.4.2.3. A new subsection 415.4.2.3 is added to read: Alarm notifications. For other than Group E occupancies, activation of a carbon monoxide detector shall initiate alarm notification in accordance with any of the following: 1. An audible and visible alarm notification throughout buildings and at the control unit. 2. Where specified in an approved fire safety plan, an audible and visible alarm in the signaling zone where the carbon monoxide has been detected and other signaling zones specified in the fire safety plan, and at the control unit. 3. Where a sounder base is provided for each detector, an audible alarm at the activated carbon monoxide detector and an audible and visible alarm at the control unit. For Group E occupancies having an occupant load of 30 or less, alarm notification shall be provided in an on-site location staffed by school personnel or in accordance with the notification requirements for other occupancies. For Group E occupancies having an occupant load of more than 30, an audible and visible alarm shall be provided in an on-site location staffed by school personnel. (30) Section 915.4.3. Section 915.4.3 is repealed in its entirety. (31) Section 915.4.4. Section 915.4.4 is repealed in its entirety. (32) Section 915.5. Amended to read: Maintenance. Carbon monoxide alarms and carbon monoxide detection systems shall be maintained in accordance with NFPA 72 and the manufacturer's instructions. Carbon monoxide alarms and carbon monoxide detectors that become inoperable or begin producing end-of-life signals shall be replaced. (33) Section 915.5.1. Subsection 915.5.1 is repealed in its entirety. (34) Section 915.5.2. Subsection 915.5.2 is repealed in its entirety. (35) Section 915.5.3. Subsection 915.5.3 is repealed in its entirety. (36) Section 915.5.4. Subsection 915.5.4 is repealed in its entirety. (37) Section 915.5.5. Subsection 915.5.5 is repealed in its entirety. (38) Section 915.6. Amended to read. Carbon monoxide detection. Carbon monoxide detection shall be installed in existing buildings in accordance with section 915. (39) Section 915.6.1. Subsection 915.6.1 is repealed in its entirety.

(Ord. No. O-2025-335, § V.C, 12-18-2025)

Ask a question about Round Rock law

Corpus searches the Round Rock sections it holds and shows the ones that match, with their citations. Free, no sign-in.