For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 7-83 — Standards for streams without base flood elevations and floodways

Code of Ordinances, City of Batesville, Mississippi (Supp. No. 54: codified through Ordinance No. 2023-08-914, adopted August 15, 2023) · Batesville Code of Ordinances § 7-83

Corpus is an independent public-information project, not the official City of Batesville website. Stable reference: corpuslaw.us/code/d03879a2-ddb5-40a1-a8a3-244290f7ec60

Sec. 7-83. - Standards for streams without base flood elevations and floodways.

When base flood elevation data and floodway data are not available in accordance with article III, section 7-36, in special flood hazard areas and community flood hazard areas without base flood elevation data, new construction and substantial improvements shall be elevated or floodproofed to elevations established by the community. The following provisions in addition to the standards of article V, section 7-81 and the enclosure standards of article V, section 7-82(4) shall apply: (1) Require that all new subdivision proposals and other proposed developments (including proposals for manufactured home parks and subdivisions) that are a single lot or five (5) acres, whichever is lesser, include within such proposals base flood elevation data; (2) The floodplain administrator shall obtain, review, and reasonably utilize any base flood elevation and floodway data available from a federal, state, or other source, in order to administer the provisions of article V. When such data are available, standards of article V, section 7-82, shall apply. If data is not available from article V, section 7-83(1) or outside sources, then the following provisions shall apply. (3) No encroachments, including fill material or other development, shall be located within a distance of the stream bank equal to five (5) times the width of the stream at the top of the bank or twenty (20) feet each side from the top of the bank, whichever is greater, unless certification by a registered professional engineer is provided demonstrating that such encroachment shall not result in any increase in flood levels during the occurrence of the base flood discharge. The enclosure standards of article V, section 7-82(4) shall apply. (4) The floodplain administrator shall require that a single lot applicant develop the base flood elevation for the development site, utilizing accepted engineering practices and procedures. Upon review of the submitted data, the administrator may accept or reject the proposed base flood elevation. When such data is accepted, standards of article V, section 7-82, shall apply. (5) Notify, in riverine situations, adjacent communities and the state coordinating office prior to any alteration or relocation of a watercourse, and submit copies of such notifications to FEMA. Assure that the flood carrying capacity within the altered or relocated portion of any watercourse is maintained. (6) Require that all manufactured homes be placed or installed using methods and practices which minimize flood damage. Manufactured homes must be elevated and anchored to resist flotation, collapse, or lateral movement. Dry stacked blocks (stacked without the use of mortar or cement to bond them together) are not allowed within the special flood hazard area.

(Ord. No. 2021-01-884, art. 5, C., 1-21-21)

Ask a question about Batesville law

Corpus searches the Batesville sections it holds and shows the ones that match, with their citations. Free, no sign-in.