For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 54-106 — Same—Diatomite filters

Omaha Municipal Code (Supp. No. 100, Update 2: codified through Ordinance No. 44760, enacted August 4, 2026) · Omaha Municipal Code § 54-106

Corpus is an independent public-information project, not the official City of Omaha website. Stable reference: corpuslaw.us/code/d0beed65-de1c-44c9-a7a6-c45dd450a4f3

Sec. 54-106. - Same—Diatomite filters.

(a) The design filtration rate for pressure or vacuum diatomite filters shall be no greater than one and one-half gallons per minute per square foot of effective filter area, except that a maximum filtration rate of two gallons per minute per square foot may be allowed for vacuum diatomaceous earth filters only where continuous "body feed" is provided. All diatomite type filters shall bear the approval of the National Sanitation Foundation (NSF). (b) Provisions shall be made to introduce a precoat of filter aid to completely cover the filter elements after each cleaning. The precoat shall have a capacity sufficient to deposit not less than one-tenth pound of filter aid on each square foot of filter area. The valving and piping shall be arranged so that, during precoating, the effluent will be refiltered or disposed to waste without passing into the pool until the effluent is clean of suspended matter. (c) Equipment shall be provided for the continuous feed of filter aid to the filter influent. The equipment shall have a capacity to feed not less than one-tenth pound of filter aid per square foot of filter area over a 24-hour period.

(Code 1980, § 54-106; Ord. No. 37382, § 35, 5-23-06)

Ask a question about Omaha law

Corpus searches the Omaha sections it holds and shows the ones that match, with their citations. Free, no sign-in.