§ 17.12.420 — Amendment to Table 315.7 of the 2025 California Fire Code
San José Municipal Code (Supp. No. 5: codified through Ordinance No. 31341, enacted August 25, 2026) · San José Municipal Code § 17.12.420
Corpus is an independent public-information project, not the official City of San Jose website. Stable reference: corpuslaw.us/code/d19c8c98-70e7-4e7e-9f50-7bef8433af9d
17.12.420 - Amendment to Table 315.7 of the 2025 California Fire Code.
Table 315.7.6(1) of the 2025 California Fire Code is amended to read as follows: Table 315.7.6(1) SEPARATION DISTANCES BETWEEN WOOD PALLET STACKS AND BUILDINGS WALL CONSTRUCTION | OPENING TYPE | WOOD PALLET SEPARATION DISTANCE (feet) ≤ 50 Pallets | 51 to 200 Pallets | >200 Pallets Masonry | None | 2 | 2 | 2 Masonry | Fire-rated glazing with open sprinklers | 2 | 5 | 20 Masonry | Fire-rated glazing | 10 | 15 | 20 Masonry | Plain glass with open sprinklers | 10 | 15 | 20 Noncombustible | None | 10 | 15 | 20 Wood with open sprinklers | - | 10 | 15 | 20 Wood | None | 15 | 30 | 90 Any | Plain glass | 15 | 30 | 90
(Ord. 31258.)