Sec. 5-67. - Fire-resistive construction requirements.

(a) Buildings of Type 2C, 3B or 5A construction located within the fire limits shall have opening protectives in accordance with the most restrictive requirements of Table 4.2 or SBC-1, Section 1414. (b) All architectural trim, such as cornices, veneers and other exterior architectural elements, attached to the exterior walls of buildings of Types 1 and 2 construction shall be constructed of approved noncombustible materials and shall be secured to the wall with metal or other approved noncombustible brackets. Inside the fire limits, wood veneers are permitted in accordance with section 5-66(i). Combustible architectural trim shall not be located with a fire separation of less than three (3) feet (914.4 mm) except fire-retardant treated wood conforming to SBC-1, Section 1403.5, for exterior use. (c) All construction, other than aerial supports, clothes dryers and similar structures less than twelve (12) feet (3658 mm) high, water tanks and cooling towers as hereinafter provided and flagpoles erected above the roof of any part of any building or structure located within the fire limits shall be constructed of noncombustible materials.

(Ord. 1985, Ch. 85-90, § 6, 12-24-85)

Ask a question about Providence law

Corpus searches the Providence sections it holds and shows the ones that match, with their citations. Free, no sign-in.