§ 14.12.225 — Monitoring
Riverside Municipal Code (Supp. No. 33: codified through Ordinance No. 7776, enacted June 23, 2026) · Riverside Municipal Code § 14.12.225
Corpus is an independent public-information project, not the official City of Riverside website. Stable reference: corpuslaw.us/code/d237e04a-f305-439b-81fd-a447649f1a4a
14.12.225 - Monitoring.
A. At the direction of the Director, any user discharging wastewater into the POTW may be required to install sampling station(s) or measuring device(s) to measure the quality and quantity of wastewater discharged or to obtain samples. Measuring devices may include, but are not limited to: flow meters and recorders, pH meters and recorders, electrical conductivity meters and recorders, process water meters, and automatic wastewater samplers. B. The sampling station and/or measuring device shall be provided by the user in compliance with this chapter and all applicable building, plumbing, and construction codes. The City may require access and that the measuring devices have a security closure that can be locked with a City lock and provide a City key. Construction shall be completed within a reasonable time as required in written notification from the Director. C. The Director may temporarily install upon the user's property devices to conduct wastewater sampling, compliance monitoring or metering operations. D. No user shall interfere with, delay, resist, or refuse entrance to authorized City personnel installing wastewater monitoring equipment on the user's property. Any permanent or temporary obstruction prohibiting direct access to the sampling station or measuring device shall be immediately removed by the user or property owner at the written or verbal request of the Director and shall not be replaced. E. The sampling station or measuring devices shall be maintained for continuous sampling or metering. The measuring devices shall be calibrated a minimum of once per year by an outside contractor, or as often as necessary to ensure accurate measurements according to manufacturer's specifications. All maintenance and calibration work shall be performed at the user's expense. F. All users that self-monitor shall have all samples collected and analyzed according to 40 CFR 403.12(b)(5). G. All user sampling and analysis must comply with 40 CFR part 403.12(b)(5) and 40 CFR part 136. The laboratory must be certified by the State of California, Department of Health Services as being competent to perform the pollutant analyses requested, shall perform all laboratory analyses and must be acceptable to the Director. All samples must have the following information: 1. The date, exact place, method, and time of sampling and the names of the person or persons taking the samples; 2. The dates the analyses were performed; 3. Who performed the analyses; 4. The analytical techniques/methods used; 5. The results of such analyses; 6. A copy of the laboratory sample analysis sheet; 7. Chain of custody; and 8. The user's completed monitoring report form. H. All users required to install and maintain measuring devices shall immediately report the failure of such devices. The immediate notification shall be by telephone call, telefax transmission, electronic report, email, personal visit, or a hand-delivered notification to the City's Environmental Compliance Office. Within five calendar days after discovery of the failure, the user shall submit a written report to the Director documenting the dates, times, and cause of the failure, and the corrective actions taken. I. Any wastewater samples taken from a user's approved or designated sampling location shall be considered representative of the wastewater discharged to the POTW. For users that have interceptors, but no approved or designated sampling location, the last chamber of the interceptor shall be the designated sampling location. The user must collect wastewater samples using 24-hour flow-proportional composite sampling techniques, unless time-proportional composite sampling or grab sampling is deemed equally representative and authorized by the Director. Where time-proportional composite sampling or grab sampling is authorized by the City, the samples must be representative of the discharge. Using protocols (including appropriate preservation) specified in 40 CFR Part 136 and appropriate EPA guidance, multiple grab samples collected during a 24-hour period may be composited prior to the analysis as follows: for cyanide, total phenols, and sulfides the samples may be composited in the laboratory or in the field; for volatile organics and oil and grease, the samples must be composited in the laboratory. Composite samples for other parameters unaffected by the compositing procedures as documented in approved EPA methodologies may be authorized by the City, as appropriate. In addition, grab samples may be required to show compliance with applicable instantaneous limits and local limits. J. All users required to self-monitor shall notify the Director of pollutant violations from any required wastewater sample within 24 hours of becoming aware of the violation. The notification may be by telephone call, telefax transmission, electronic report, or a personal visit to the City's Environmental Compliance Office. The violation report shall contain the date and time of the sample, the daily discharge flow for the sample, possible explanations for the violation, and the date scheduled for the required resample. Failure to report pollutant violations as stated is a violation of this chapter and may subject the user to enforcement actions. K. All users required to take daily 24-hour readings of their wastewater effluent flow shall notify Director of exceedance of its permitted flow within 24 hours of discovering the exceedance by telephone call, telefax transmission, electronic report, personal visit, or a hand delivered notification, to the City's Environmental Compliance Office or file a monthly report indicating the days of the month when the permitted flow was exceeded and the reason for the exceedance. The monthly report shall be submitted to the City's Environmental Compliance Office by the fifth business day following the end of the preceding month. The flow exceedance notice shall have the total flow, date of the violation, the reason for the flow exceedance, and the name of the person reporting the flow exceedance. Failure to report such flow exceedance is unlawful and may subject the user to enforcement actions. L. All users with a discovered pollutant violation shall resample their wastewater discharge for that pollutant. This mandatory resampling is independent of any other wastewater sampling requirement. User shall notify the Director within 24 hours of becoming aware of the violation. User shall submit the laboratory results and all required forms from the resamples of the violation to the Director no later than 30 calendar days after the user discovers or becomes aware of the violation and a written explanation detailing the cause(s) and correction action(s) of the violation to the Director no later than ten calendar days after the user discovers or becomes aware of the violation. Failure to submit the laboratory results and all required documents within the 45-day requirement shall result in significant noncompliance for the user and the issuance of a notice of violation to the user. M. All users whose wastewater discharge is sampled by the City and themselves shall be responsible for all resampling requirements contained in subsection L of this section when a pollutant violation is detected. The City shall notify the user of the resampling requirements by a telephone call, telefax transmission, email, or personal visit within 72 hours of confirming a pollutant violation. The repeat sampling is required to be performed within 30 days of becoming aware of a violation. N. All users which desire to conduct their own wastewater sampling, or receive samples split from City samples, shall submit a written plan describing the equipment used, equipment cleaning methodology, employee training, sample preservation methods, and chain of custody procedures. The user's wastewater sampling plan must be approved by the Director prior to the implementation of the plan. Any sample taken by a user without an approved plan or from an unapproved laboratory shall not be valid and may subject the user to enforcement actions. O. All users are required to submit all monitoring results including non-permit required samples according to 40 CFR 403.12(g) sampled at the appropriate sample point within 15 calendar days of receiving the sample or monitoring results. P. All permitted users that take more than one grab sample in a single calendar day to demonstrate compliance with oil and grease shall also comply with the following conditions: 1. A minimum of four grab samples separated by a minimum of two hours each shall be taken in a single calendar day; 2. Each individual oil and grease grab sample shall be analyzed separately and the analytical results from each sample shall be averaged; 3. No single oil and grease grab sample shall exceed the user's permitted limit by more than 40 percent; and 4. The average result from all individual oil and grease grab samples taken in a single calendar day shall not exceed the user's permitted limit.
(Ord. 7551 §5, 2021; Ord. 7362 §6, 2017; Ord. 7099 §2, 2010; Ord. 7032 §2, 2009; Ord. 6637 §2 (part), 2002; Ord. 6232 §2 (part), 1995)
Ask a question about Riverside law
Corpus searches the Riverside sections it holds and shows the ones that match, with their citations. Free, no sign-in.
